Records from 1985 to 1997. Most recent: inspection, 3 February 1997.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
3 February 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 400061
4 May 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 652299
17 January 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 355977
17 January 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 358054
2 July 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 351509
2 July 1992
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1263770
5 August 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 473401
13 December 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 340807
13 December 1990
Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1225212
9 June 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 330862
9 June 1989
Certificate of Compliance
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1210318
11 May 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 323154
11 May 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1347264
28 December 1987
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017575
24 December 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 320695
9 September 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 447402
24 March 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 314986
27 February 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 507308
9 August 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 310676
27 February 1986
Examination of Repairs
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 988350
26 February 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 307634
26 February 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 998386
22 May 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 302144
22 May 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 983902
Navigation
Issued 3 February 1997
Resolved
INSTALL OR PROVIDE COTP EQUIVALENT FOR AUTO PILOT OR INDICATOR ALARM ON BRIDGE. 33CFR167.440_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 February 1997
Resolved 5 February 1997
Deck/Cargo
Issued 3 February 1997
Resolved
PROVIDE OVERFILL PLACARD AT OVERFILL ALARM ON MAIN DECK IAW 33CFR155.480._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 3 February 1997
Resolved
PROVE PROPER OPERATION OF ALL OVERFILL ALARMS IN CARGO CONTROL PRIOR TO ONLOADING CARGO IN THE U.S. (33CFR155.480)
Condition: Unknown
Due 3 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 17 January 1993
Resolved
PROHIBITED DISCHARGE OF PLASTICS
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997
Accommodation/Occupational Safety
Issued 17 January 1993
Resolved
PROHIBITED DISCHARGE OF PLASTICS
Condition: Unknown
Due 3 February 1997
Resolved 3 February 1997
Fire Fighting
Issued 24 December 1987
Resolved
FIRE IN PUMP ROOM
Condition: Unknown
Due 29 December 1987
Resolved 24 December 1987
Fire Fighting
Issued 26 February 1986
Resolved
PRIO TO NEXT U.S. PORT, MUST MAKE PERMANENT REPAIRS TO FIRE FIGHTING FOAM LINE. THE LINE SPLIT ON THE SUPLLY TO #5 FOAM MONITOR DURING PRESSURE TEST.
Condition: Unknown
Due 27 February 1987
Resolved 26 February 1986
Navigation
Issued 26 February 1986
Resolved
PRIOR TO NEXT U.S. PORT, MUST HAVE ONBOARD A CURRENT MAGNETIC COMPASS DEVIATION TABLE/GRAPH. 33 CFR 164.35(C)
Condition: Unknown
Due 26 February 1986
Resolved 26 February 1986
Navigation
Issued 22 May 1985
Resolved
NOS CHARTS 18720, 18740, 18746, 18749 AND 18751 WERE OUTDATED. NOS COAST PILOT VOL. 7 AND USCG LIGHT LIST VOL. III WERE NOT CORRECTED.
Condition: Unknown
Due 22 May 1985
Resolved 22 May 1985
Fire Fighting
Issued 22 May 1985
Resolved
STOW FIREMAN'S OUTFITS IN 2 SEPERATE LOCATIONS. IN BOTH APPARATUS MUST BE RIGGED AND STOWED READY FOR RAPID USE IN AN EMERGENCY. THIS ITEM TO BE COMPLETED PRIOR TO VESSEL'S RETURN TO U.S. WATERS.
Condition: Unknown
Due 22 May 1985
Resolved 22 May 1985
Fire Fighting
Issued 22 May 1985
Resolved
CROP OUT AND RENEW APPROXIMATELY 40' OF WASTED AND HOLED FOAM PIPING BETWEEN #2 AND #3 FOAM MONITORS. THIS ITEM TO BE COMPLETED PRIORTO THE VESSEL'S RETURN TO U.S WATERS.
Condition: Unknown
Due 22 May 1985
Resolved 22 May 1985
Fire Fighting
Issued 22 May 1985
Resolved
CROP OUT AND RENEW NUMEROUS AREAS OF WASED FIRE MAIN AND FOAM PIPING ON DECK. THIS ITEM TO BE COMPLETED PRIOR TO THE VESSEL'S RETURN TO U.S WATERS.
Condition: Unknown
Due 22 May 1985
Resolved 22 May 1985
Deck/Cargo
Issued 22 May 1985
Resolved
PROVIDE SPAN GAS ON BOARD TO CALIBRATE FIXED O2 METER. THIS ITEM TO BE COMPLETED PRIOR TO THE VESSEL'S RETURN TO U.S WATERS.
Condition: Unknown
Due 22 May 1985
Resolved 22 May 1985