Records from 1984 to 1994. Most recent: inspection, 5 January 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
5 January 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 698020
23 December 1993
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 363622
21 December 1993
Deficiency Check · Administrative Inspection · Tank Vessel Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1377099
6 December 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 657176
20 November 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 657175
6 November 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 482061
1 January 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 341081
1 January 1991
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 918538
1 January 1991
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 947272
28 January 1989
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 328151
22 December 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 327491
22 December 1988
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037851
22 December 1988
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037852
18 March 1987
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 454127
8 May 1986
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 308443
29 March 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 473107
28 March 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1292164
8 November 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 453281
Fire Fighting
Issued 21 December 1993
Resolved
MAKE PERMANENT REPAIR TO FIBERGLASS PATCH ON FIRE MAIN IN WAY OF STARBOARD MAIN DECK PRIOR TO ENTRY INTO A U.S. PORT.
Condition: Unknown
Due 31 March 1994
Resolved 10 January 2002
Resolution: Administratively closed due to age of deficiencies.
Documentation
Issued 22 December 1988
Resolved
VESSEL COULD NOT PRODUCE A PROPER STATIC LIQUID PRESSURE TEST OF THE CARGO PIPING. TEST WAS CONDUCTED AT TO LOW A PRESSURE.
Condition: Unknown
Due 22 December 1988
Resolved 22 December 1988
Unknown
Issued 28 March 1985
Resolved
VERIFY CERTIFICATE OF CLASSIFICATION STATEMENT - "TANKER, OILS-FLASHPOINT BELOW 61 DEGREES C." IS ACCURATE.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Unknown
Issued 28 March 1985
Resolved
PROVIDE TWO ADDITIONAL FIREMANS OUTFITS AS IS REQUIRED BY SOLAS 1974. REGULATION 17 (TOTAL OF 4 OUTFITS REQUIRED)
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Unknown
Issued 28 March 1985
Resolved
UPON ARRIVAL AT THE NEXT UNITED STATES PORT, THE MASTER IN THE "NOTICE OF ARRIVAL" SHALL MAKE KNOWN THE ABOVE DISCREPANCIES TO THE COAST GUARD.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Unknown
Issued 28 March 1985
Resolved
PRIOR TO RETURNING TO US WATERS: REPAIR MECHANICAL MEANS OF CLOSING DRAINSIN BUNKER OIL CONTAINMENT.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Unknown
Issued 28 March 1985
Resolved
PRIOR TO RETURNING TO US WATERS: MAKE REPAIRS TO IMPROPERLY OPERATING IGS (DETERIORATED BLOWER BLADES, SCRUBBER, LEAKING VALVES, O2 ANALIZER, ALARMS,PRESSURE RECORDER). PROVIDE CLASS SOCIETY SURVEY OF REPAIRS AND PROPER OPERATION. PLACE FLAG ADMIN LTR OF VERIFICATION OF SAME ABOARD VESSEL.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985