MAURY USCG vessel records Sign in
← All vessels

FLY N TIME

FLY N TIME is a 2000 passenger vessel (uninspected). The Coast Guard has recorded 21 inspections since 2000, most recently in August 2021, along with 59 deficiencies.

Records from 2000 to 2021. Most recent: inspection, 9 August 2021.

Built
2000
Last inspected
9 August 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE7511
Flag
UNITED STATES
367394140
Maury page id
psix-2244

Inspections, by type

Years with a record 12 calendar years (2000–2021)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDL5060MMSI 367394140 · active · compulsorily equipped · granted 14 March 2020, expires 14 March 2030
WDE7511MMSI 367394140 · expired · compulsorily equipped · granted 6 February 2009, cancelled 13 April 2019
WDE5717MMSI 367370680 · expired · compulsorily equipped · granted 29 July 2008, cancelled 29 September 2018
WDE3963MMSI 367346620 · expired · compulsorily equipped · granted 1 April 2008, cancelled 2 June 2018
WDB4046MMSI 366894120 · expired · compulsorily equipped · granted 17 May 2003, cancelled 20 July 2013 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 21

9 August 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7283596
5 June 2020 Drydock Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6968962
2 July 2019 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6733916
20 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6689099
17 July 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6483469
8 February 2018 Internal Structural Exam · COI Inspection · DAPI Audit · Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6351797
20 September 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6270936
11 January 2017 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6069598
4 March 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5827214
12 January 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5796183
20 November 2015 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5767474
24 October 2008 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3350568
13 August 2008 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3292863
26 March 2008 COI Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3172785
21 March 2005 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2315184
9 October 2003 Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1740706
5 June 2001 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1395733
16 March 2000 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1047038
1 March 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1074277
1 March 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1074279
1 March 2000 Initial Certification · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1467199

Deficiency record · 59

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 June 2019 Resolved
A pre-engineered fixed fire extinguishing system must: Automatically shut down all ventilation and engines. Vessels fire extinguishing system did not shut down engines upon simulated test.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2019
Resolved 2 July 2019
Resolution: Tested the engine kill switch as part of the installed fire suppression system. Test was satisfactory.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 June 2019 Resolved
Every vessel that operates in the high seas must have an EPIRB installed. Vessels EPIRB was found to have an expired battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2019
Resolved 28 June 2019
Resolution: Captain/Operator sent in satisfactory photos of the new battery unit for the EPIRB.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 June 2019 Resolved
Each hydrostatic release unit must be serviced: within 12 months of its manufacture and within 12 months of each subsequent servicing. Vessels hydrostatic release for the EPIRB was expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2019
Resolved 28 June 2019
Resolution: Captain/operator sent in satisfactory photos of the new hydrostatic release unit for the vessels EPIRB.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 June 2018 Resolved
Port side navigational light was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2018
Resolved 17 July 2018
Resolution: Verified the port running light is opeartional.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 19 January 2017 Resolved
Needs consortium letter for crew on board and supervisory training for [name withheld] 46 CFR 16.401 & 201.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 February 2017
Resolved 7 June 2018
Resolution: Reviewed DAPI and is considered satisfactory.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 19 January 2017 Resolved
One fire extinguisher needs proper mount bracket IAW 46 CFR 181.520
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 February 2017
Resolved 7 June 2018
Resolution: Reviewed mounting brackets of extinguisher and is considered satisfactory.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 January 2017 Resolved
Check and relabel all life jackets and stow in proper location IAW 46 CFR 180.78
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 February 2017
Resolved 7 June 2018
Resolution: PFD storage is considered satisfactory.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 January 2017 Resolved
Label life ring and clean, have life ring holder installed IAW 46 CFR 180.71
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 February 2017
Resolved 7 June 2018
Resolution: Markings on lifebuoys are considered satisfactory.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 January 2017 Resolved
Child life jacket stowage door is missing a lock mechanism, repair or replace IAW 46 CFR 176.806
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2017
Resolved 7 June 2018
Resolution: Storage of PFDs are considered satisfactory.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 19 January 2017 Resolved
Updated nav pubs and charts IAW 46 CFR 184.420: Navrules, chart, lightlist and notices to mariners.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 February 2017
Resolved 7 June 2018
Resolution: Charts and publications were reviewed and are considerd satisfactory.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 January 2017 Resolved
Bilge pumps and navlights need to be labeled and operate correctly. Label panel with on/off, auto, manual IAW 46 CFR 182.530
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 February 2017
Resolved 7 June 2018
Resolution: Confirmed labels for all indicators at the ops station
Engineering › Fuel Oil Service System › Tank
Issued 18 February 2016 Resolved
Fuel tank was not grounded. Ground fuel tank
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 4 March 2016
Resolution: Added bonding wire to ground fuel tank.
Navigation › Piloting/Steering › Marine Charts
Issued 18 February 2016 Resolved
Navigation publications were not up to date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 4 March 2016
Resolution: Had new nav pubs
Engineering › Fuel Oil Service System › Ventilation
Issued 12 January 2016 Resolved
Vent covers were missing from ENG ventilation system.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 4 March 2016
Resolution: Vent covers were onboard
Operations/Management › Drills/Instruction › Safety Orientation
Issued 12 January 2016 Resolved
Man overboard and fire drills did not correspond with emergency instructions placard.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 4 March 2016
Resolution: Updated emergency instructions placard to reflect actual procedure.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 12 January 2016 Resolved
Line attached to ring lifebuoy was corroded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 4 March 2016
Resolution: Replaced line.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 August 2008 Resolved
Provide and install guards over rotating machinery as per 46 CFR 177.960
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 1 June 2009
Resolution: Guards were installed over rotating machinery.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 13 August 2008 Resolved
Provide onboard all required lifesaving equipment as per 46 CFR 180
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 1 June 2009
Resolution: Proper lifesaving equipment is on board.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 13 August 2008 Resolved
Prove proper operation of and service of pre-engineered CO2 fire extiguishing system located in engine room as per 46 CFR 181.420
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 1 June 2009
Resolution: Pre-engineered fire extinguishing system has been serviced and is operable.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 August 2008 Resolved
Provide the required navigation charts and publications as per 46 CFR 184.420
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 1 June 2009
Resolution: All required navigation pubs and charts are on board.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 August 2008 Resolved
Provide a Certificate of Documentation as per 46 CFR 67.7
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 1 June 2009
Resolution: Valid COD is on board.
Documentation › Certificates/Documents › Stability Letter
Issued 13 August 2008 Resolved
Provide a Stability Letter as per 46 CFR 176.306
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 1 June 2009
Resolution: Valid stability letter is on board.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 13 August 2008 Resolved
Prove proper operation of main propulsion engine and engine shutdown at operating station as per 46 CFR 184,620(b)
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 1 June 2009
Resolution: Main engine is operable and shuts down at the operating station.
Engineering › Fuel Oil Service System › Valve, Control
Issued 13 August 2008 Resolved
Prove proper operation of fuel shutoffs as per 46 CFR 182.455(b)(4)
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 1 June 2009
Resolution: Fuel shutoffs are operable.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 13 August 2008 Resolved
Provide a current training logbook as per 46 CFR 185.420(c)
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 1 June 2009
Resolution: Proper, updated training log is on board.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 August 2008 Resolved
Prove proper operation of navigation lights as per 46 CFR 184.420
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 1 June 2009
Resolution: All navigation lights are operable.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 13 August 2008 Resolved
Provide fire servicing certificate as per 46 CFR 176.810
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 1 June 2009
Resolution: Valid fire servicing certificate is on board.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 13 August 2008 Resolved
Properly label lifejacket stowage for adult and child lifejackets as per 46 CFR 180.78
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 1 June 2009
Resolution: All PFD stowage is properly marked.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 13 August 2008 Resolved
Properly segregate adult and child lifejackets as per 46 CFR 180.78
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 1 June 2009
Resolution: Adult and child PFD''s are properly segregated.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 13 August 2008 Resolved
Provide and apply proper retroreflective tape to lifejackets as per 46 CFR 180.75 and 161.012
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 1 June 2009
Resolution: All PFD''s are properly marked with retroreflective tape.
Construction/Loadline › Penetrations
Issued 9 June 2003 Resolved
INSTALL ACCESS PLATES IN FORWARD HOLD. LEGACY COMPONENT DESC: Hull Access
Condition: Design Flaw
Due 9 July 2003
Resolved 9 October 2003
Lifesaving › Lifejacket/PFD (Type IV)
Issued 9 June 2003 Resolved
REPLACE 24" LIFERING AND 60' OF FLOATABLE LINE, WATERLIGHT WITH 6' OF FLOATABLE LINE, DETACHABLE CLIP, RETROFLECTIVE MATERIAL, AND STENCILED WITH VESSEL NAME. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 9 July 2003
Resolved 29 October 2003
Engineering › Bilge Water Management System
Issued 9 June 2003 Resolved
INSTALL POSITIVE CLOSURE DEVICES ON ALL BILGE DISCHARGES. INSTALL ACCESS FOR FORWARD BLIGE DISCHARGE. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 9 July 2003
Resolved 9 October 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 9 June 2003 Resolved
ADD ONE ADDITIONAL USCG TYPE B-II FIRE EXTINGUISHER. LEGACY COMPONENT DESC: Number
Condition: Improper Installation
Due 9 July 2003
Resolved 9 October 2003
Lifesaving › Hand Flares
Issued 9 June 2003 Resolved
PROVIDE 12 HAND HELD DAY/NIGHT FLARES. LEGACY COMPONENT DESC: Quantity
Condition: Improper Installation
Due 9 July 2003
Resolved 9 October 2003
Engineering › Bilge Water Management System
Issued 9 June 2003 Resolved
PROVIDE PORTABLE BILGE PUMP. LEGACY COMPONENT DESC: Portable Pump
Condition: Improper Installation
Due 9 July 2003
Resolved 9 October 2003
Communications › Radio Communications
Issued 9 June 2003 Resolved
PROVIDE FCC RADIOTELEPHONE SAFETY CERTIFICATE. LEGACY COMPONENT DESC: Certificates
Condition: Improper Installation
Due 9 July 2003
Resolved 9 October 2003
Navigation › Collision/Grounding Avoidance
Issued 9 June 2003 Resolved
PROVIDE SHIPS BELL. LEGACY COMPONENT DESC: Bell
Condition: Improper Installation
Due 9 July 2003
Resolved 9 October 2003
Operations/Management › Drills/Instruction
Issued 9 June 2003 Resolved
POST EMERGENCY INSTRUCTIONS. LEGACY COMPONENT DESC: Emergency Insructions
Condition: Improper Installation
Due 9 July 2003
Resolved 9 October 2003
Communications › Radio Communications
Issued 9 June 2003 Resolved
POST EMERGENCY BROADCAST PLACARD. LEGACY COMPONENT DESC: Emergency Broadcat Placard.
Condition: Improper Installation
Due 9 July 2003
Resolved 9 October 2003
Lifesaving › Hand Flares
Issued 9 June 2003 Resolved
Prior to the carriage of passengers, label flare box "DISTRESS SIGNALS", as per 46CFR185.614. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Due 9 October 2003
Resolved 29 October 2003
Lifesaving › Lifejacket/PFD (General)
Issued 9 June 2003 Resolved
Prior to the carriage of passengers, label life preserver stowage as per 46CFR180.78. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Due 9 October 2003
Resolved 29 October 2003
Operations/Management › Drills/Instruction
Issued 9 June 2003 Resolved
Prior to the carriage of passengers, provide Red Cross First Aid/CPR cards for 50% of crew as per NVIC 1-91. LEGACY COMPONENT DESC: First aid/ CPR cards
Condition: Unknown
Due 9 October 2003
Resolved 29 October 2003
Navigation › Piloting/Steering
Issued 9 June 2003 Resolved
Prior to the carriage of passengers, provide navigation publications as per 46CFR184.420. LEGACY COMPONENT DESC: Publications
Condition: Improper/Lack of Maintenance
Due 9 October 2003
Resolved 29 October 2003
Navigation
Issued 5 June 2001 Resolved
INSTALL 8" BELL.
Condition: Unknown
Due 22 June 2001
Resolved 9 June 2003
Resolution: RE-ISSUED
Lifesaving
Issued 5 June 2001 Resolved
INSTALL CORROSION RESISTANT LINK TO WATERLIGHT ON LIFE RING PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 22 June 2001
Resolved 9 June 2003
Resolution: RE-ISSUED
Construction/Loadline
Issued 5 June 2001 Resolved
INSTALL POSITIVE CLOSURE DEVICE ON BILGE DISCHARGES.
Condition: Unknown
Due 22 June 2001
Resolved 9 June 2003
Resolution: RE-ISSUED.
Construction/Loadline
Issued 5 June 2001 Resolved
INSTALL PORTABLE BILGE PUMP PRIOR TO CARRIAGE OF PASENGERS.
Condition: Unknown
Due 22 June 2001
Resolved 9 June 2003
Resolution: RE-ISSUED.
Documentation
Issued 5 June 2001 Resolved
PROVIDE CURRENT DRUG CONSORTIUM AND CREW LIST.
Condition: Unknown
Due 22 June 2001
Resolved 9 June 2003
Resolution: SAT
Documentation
Issued 5 June 2001 Resolved
PROVIDE CURRENT CREW TRAINING LOGS (MAN OVERBOARD, ABANDON SHIP, FIRE, AND EPIRB TESTS).
Condition: Unknown
Due 22 June 2001
Resolved 9 June 2003
Lifesaving
Issued 5 June 2001 Resolved
PROPERLY REGISTER EPIRB.
Condition: Unknown
Due 22 June 2001
Resolved 9 June 2003
Resolution: SAT
Documentation
Issued 5 June 2001 Resolved
PROVIDE FCC RADIO STATION LICENSE AND FCC RADIOTELEPHONE SAFETY CERTIFICATE.
Condition: Unknown
Due 22 June 2001
Resolved 9 June 2003
Resolution: RE-ISSUED
Documentation
Issued 5 June 2001 Resolved
PROVIDE STABILITY LETTER.
Condition: Unknown
Due 22 June 2001
Resolved 9 June 2003
Resolution: SAT
Lifesaving
Issued 5 June 2001 Resolved
PROVIDE 3 RED AND 3 ORANGE HAND HELD FLARES PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 22 June 2001
Resolved 9 June 2003
Resolution: RE-ISSUED.
Lifesaving
Issued 16 March 2000 Resolved
INSTALL 406 MHZ CAT. 1 EPIRB AS PRIMARY LIFESAVING PRIOR TO CARRAGE OF PASSENGERS PASSED DEMARCATION.
Condition: Unknown
Due 28 March 2000
Resolved 29 March 2000
Lifesaving
Issued 16 March 2000 Resolved
MOUNT LIFERING WITH 60' OF FLOATABLE LINE ATTACHED PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 20 March 2000
Resolved 29 March 2000
Engineering
Issued 1 March 2000 Resolved
Ground fuel vent lines.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Lifesaving
Issued 1 March 2000 Resolved
Conduct emergency drills prior to operating.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000
Documentation
Issued 1 March 2000 Resolved
Provide licensed operator enrolled in an approved random drug testing program.
Condition: Unknown
Due 1 March 2000
Resolved 1 March 2000

Ownership record