Records from 1985 to 2001. Most recent: inspection, 27 September 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
27 September 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 294099
25 September 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 293913
13 September 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 293724
5 February 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 286686
10 February 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 412632
6 July 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 368200
5 July 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 368138
19 September 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 360967
6 June 1992
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 351288
7 May 1990
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 336925
28 March 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 329278
7 January 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 320692
6 November 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 319386
17 November 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 312693
25 September 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 311594
25 September 1986
Examination of Repairs
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1005991
13 March 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 501059
2 August 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 303355
Deck/Cargo
Issued 27 September 2001
No resolution recorded
Valve by way of hydraulic tank reservoir is leaking hyraulic fluid. Repair_x001C_to the satisfaction of class prior to next US port. (SOLAS 74 REG I/11)
Condition: Unknown
Due 1 October 2001 — due date passed with no resolution recorded
Deck/Cargo
Issued 27 September 2001
No resolution recorded
#6 cargo hold controls are leaking excessively. Make repairs to the satisfaction of class prior to the next US port. (SOLAS 74 REG I/11)
Condition: Unknown
Due 1 October 2001 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 27 September 2001
No resolution recorded
Cockroaches were found on deck "C" inside superstructure, galley and food preparation areas. Show proof of fumigation prior to next US port. (ILO 147)
Condition: Unknown
Due 1 October 2001 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 27 September 2001
No resolution recorded
Several toilets cannot be flushed without buckets. Make permenant repairs prior to next US port. (ILO 147)
Condition: Unknown
Due 1 October 2001 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 27 September 2001
No resolution recorded
Placard not posted to satisfaction of (33CFR159.59). Prove proper posting_x001C_ of MSD placard prior to next US port.
Condition: Unknown
Due 1 October 2001 — due date passed with no resolution recorded
Navigation
Issued 27 September 2001
No resolution recorded
Upper ram main seal is leaking excessivly, approximately 30 drops per minute, on #1 outboard and #2 inboard seals. Make permanent repairs to the satisfaction of class prior to next US port. (SOLAS 74 REG I/11)
Condition: Unknown
Due 1 October 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 5 February 2001
Resolved
Load line not marked in a contrasting color to the hull IAW ILLC Annex 1, Reg 8.
Condition: Unknown
Due 28 September 2001
Resolved 28 September 2001
Engineering
Issued 5 February 2001
Resolved
Fastening devices (nuts and bolts) on port and starboard bunkering valve bonnets and flanges wasted more than 80%. [33 CFR 156.130(h)]
Condition: Unknown
Due 28 September 2001
Resolved 28 September 2001
Electrical
Issued 5 February 2001
Resolved
Exposed electrical wires and loose junction box covers in #2 Deck Store House and on deck light, port side #2 Deck Store House.
Condition: Unknown
Due 28 September 2001
Resolved 28 September 2001
Lifesaving
Issued 5 February 2001
Resolved
Walkway between #4 and 5 cargo holds, port side, wasted.
Condition: Unknown
Due 28 September 2001
Resolved 28 September 2001
Fire Fighting
Issued 5 February 2001
Resolved
Fixed fire sprinkler nozzel in paint locker isolated and not immediately available for use due to leakage.
Condition: Unknown
Due 25 September 2001
Resolved 27 September 2001
Fire Fighting
Issued 5 February 2001
Resolved
International Shore Connection on board vessel did not meet the construction requirements of SOLAS 60, II/Reg 56(h) in that it was fitted with only three bolt holes.
Condition: Unknown
Due 25 September 2001
Resolved 27 September 2001
Unknown
Issued 10 February 1998
Resolved
REMOVE OIL FROM BUNKERING CONTAINMENT (EXCESSIVE).
Condition: Unknown
Due 17 February 1998
Resolved 17 February 1998
Unknown
Issued 10 February 1998
Resolved
PLACE BOLT IN BACKING PLATE FLANGES FOR BUNKERING STATION (MISSING).
Condition: Unknown
Due 17 February 1998
Resolved 17 February 1998
Deck/Cargo
Issued 10 February 1998
Resolved
REPLACE BRAKE PAD FOR PORT ANCHOR WINDLESS (CORRODED)(CLASS CONDITION).
Condition: Unknown
Due 5 February 2001
Resolved 5 February 2001
Deck/Cargo
Issued 10 February 1998
Resolved
PLACE BRAKE PAD FOR STARBOARD SIDE FORWARD MOORING WINCHES (MISSING).
Condition: Unknown
Due 5 February 2001
Resolved 5 February 2001
Fire Fighting
Issued 10 February 1998
Resolved
CONDUCT FIRE DRILL TO THE SATISFACTION OF SOLAS/USCG (PROCEDURES).
Condition: Unknown
Due 17 February 1998
Resolved 17 February 1998
Construction/Loadline
Issued 10 February 1998
Resolved
PAINT LOADLINE CONTRASTING TO HULL.
Condition: Unknown
Due 17 February 1998
Resolved 17 February 1998
Lifesaving
Issued 10 February 1998
Resolved
PLACE PROTECTIVE GUARD OVER ROTATING EQUIPMENT FOR PORT LIFEBOAT (MISSING).
Condition: Unknown
Due 17 February 1998
Resolved 17 February 1998
Lifesaving
Issued 10 February 1998
Resolved
REPAIR FUEL LINE RETURN PORT LIFEBOAT (LOOSE).
Condition: Unknown
Due 17 February 1998
Resolved 17 February 1998
Accommodation/Occupational Safety
Issued 19 September 1993
Resolved
VESSEL FALILED TO HAVE CERTIFICATION LABEL AFFIXED TO MSD.
Condition: Unknown
Due 5 February 2001
Resolved 5 February 2001
Navigation
Issued 7 May 1990
Resolved
A VIO OF 33CFR164.30 IN THAT THE FOREIGN EQUIVALENT TO USCG LIGHT LIST VOL_x001C_II (NP 82 VOL J 1986) WAS NOT CURRENTLY CORR UP THRU NTM 7/90, WHICH WERE _x001C_REASONABLY AVAILABLE AND CONTAINED CORRS APPLICABLE TO THE VSLS RTE FM SMITH PT. VA. TO BALTIMORE HBR. _x001C_
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Documentation
Issued 7 May 1990
Resolved
A VIO OF 33CFR155.750 IN THAT THE OIL TRANSFER PROCEDURES REQ BY 33CFR155._x001C_720 WERE INCOMPLETE IN THAT THEY DID NOT CONTAIN THE REQ INFO DESCRIBED IN 33CFR155.750 PARAGRAPHS (A)(3),(4),(5),(6),(7) AND (8'). _x001C__x001C_
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Navigation
Issued 7 May 1990
Resolved
A VIO OF 33CFR164.30 IN THAT THE VSL DID NOT HAVE ON BOARD US CHARTS 12230,12263, OR THEIR FOREIGN EQUIVALENT WHICH WERE REQUIRED FOR THE VSLS RTE FM_x001C_SMITH PT. VA. TO BALTIMORE HBR._x001C_ _x001C_
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Navigation
Issued 7 May 1990
Resolved
A VIO OF 33CFR164.30 IN THAT THE FOREIGN EQUIVALENT TO US COAST PILOT VOL 3(NP 69 VOL II), USED BY THE VSL WAS NOT CORRECTED UP THRU SUPPLEMENT #6 _x001C_ WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRS APPLICABLE TO THE VSLS _x001C_RTE FM SMITH PT. VA. TO BALTIMORE HBR._x001C_
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Navigation
Issued 28 March 1989
Resolved
VESSEL DID NOT HAVE A CURRENTLY CORRECTED COPY OF COAST GUARD LIGHT LIST OR AVAILABLE EXTRACT.
Condition: Unknown
Due 29 March 1989
Resolved 28 March 1989
Navigation
Issued 28 March 1989
Resolved
VESSEL'S TIDE TABLES WERE OUTDATED & NOT CORRECTED.
Condition: Unknown
Due 29 March 1989
Resolved 28 March 1989
Navigation
Issued 28 March 1989
Resolved
VESSEL'S TIDAL CURRENT TABLE WAS OUTDATED. (1988)
Condition: Unknown
Due 29 March 1989
Resolved 28 March 1989
Navigation
Issued 28 March 1989
Resolved
CHART 11370 NOT UPDATED, LAST CORRECTION 25/85
Condition: Unknown
Due 29 March 1989
Resolved 28 March 1989
Navigation
Issued 28 March 1989
Resolved
VESSEL DID NOT HAVE NOTICE TO MARINERS ONBOARD FOR UPDATING CHARTS & PUBLI-CATIONS ONBOARD.
Condition: Unknown
Due 29 March 1989
Resolved 28 March 1989
Navigation
Issued 28 March 1989
Resolved
VESSEL'S U.S. COAST PILOT NOT UPDATED OR CORRECTED
Condition: Unknown
Due 29 March 1989
Resolved 28 March 1989
Navigation
Issued 7 January 1988
Resolved
INOP RADAR
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Navigation
Issued 25 September 1986
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE VSL DID NOT HAVE O/B U.S. CHART #12245 OR ITS FOREIGN EQUIV,WHICH WAS REQ FOR THE VSL'S ROUTE FROM VA CAPES TO NORFOLK AND WESTERN COAL PIERS,NORFOLK,VA.
Condition: Unknown
Due 25 September 1986
Resolved 25 September 1986
Navigation
Issued 25 September 1986
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE B.A. SAILING DIRECTIONS #69,VOLII,O/B THE VSL WERE NOT CORRECTED TO NTM 45/85,WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM VA CAPES TO NORFOLK AND WESTERN COAL PIERS,NORFOLK,VA. NO U.S. EQUIV O/B.
Condition: Unknown
Due 25 September 1986
Resolved 25 September 1986
Documentation
Issued 25 September 1986
Resolved
A VIO OF 33 CFR 155.750 IN THAT THE OTP REQ BY 33 CFR 155.720 WERE INCOMPLETE IN THAT THEY DID NOT CONTAIN A LIST OF PRODUCTS,PROCEDURES FOR EMPTYING DISCHARGE CONTAINMENT,TOPPING OFF,NUMBER OF PERSONS,DUTIES BY TITLE,PROCEDURES AND ASSIGNMENTS FOR TENDING VSL'S MOORINGS.
Condition: Unknown
Due 25 September 1986
Resolved 25 September 1986
Navigation
Issued 2 August 1985
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE MANEUVERING INFO FACT SHEET REQ BY 33 CFR 164.35(G) DID NOT CONTAIN: MANEUVERING INFO FOR NORMAL LOAD CONDITION.
Condition: Unknown
Due 13 March 1986
Resolved 2 August 1985