MAURY USCG vessel records Sign in
← All vessels

BRITTANY

BRITTANY is a 1974 tank ship. The Coast Guard has recorded 6 inspections since 1985, most recently in October 1989, along with 9 deficiencies.

Records from 1985 to 1989. Most recent: inspection, 23 October 1989.

Built
1974
Last inspected
23 October 1989
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7373236 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224408
Flag
PANAMA
—
Maury page id
psix-224408

Inspections, by type

…with no type recorded4
Years with a record 3 calendar years (1985–1989)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 37 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it233348 - Dead Weight, Ton
105178 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 6

23 October 1989 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 895824
18 August 1989 MARPOL Annex I Examination · Certificate of Compliance
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1034830
19 February 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 314407
20 November 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 305478
20 November 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 307401
20 November 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 991824

Deficiency record · 9

Fire Fighting
Issued 18 August 1989 Resolved
INSTALL FIRE FIGHTING SYSTEM IN VSL'S PAINT LOCKER.
Condition: Unknown
Due 18 August 1989
Resolved 18 August 1989
Deck/Cargo
Issued 18 August 1989 Resolved
MAKE PERMANENT REPAIRS TO STBD BUNKER OIL CONTAINMENT.
Condition: Unknown
Due 18 August 1989
Resolved 18 August 1989
Navigation
Issued 18 August 1989 Resolved
NO CURRENT OR CURRENTLY CORRECTED U.S. COAST PILOT OR ITS FOREIGN EQUIVALENT ON BOARD.
Condition: Unknown
Due 18 August 1989
Resolved 18 August 1989
Fire Fighting
Issued 18 August 1989 Resolved
SUBMIT FOAM SAMPLE FOR ANNALYSIS.
Condition: Unknown
Due 18 August 1989
Resolved 18 August 1989
Deck/Cargo
Issued 18 August 1989 Resolved
REPLACE O2 PORTABLE METER.
Condition: Unknown
Due 18 August 1989
Resolved 18 August 1989
Fire Fighting
Issued 20 November 1985 Resolved
REPLACE DETERIORATED SECTION OF FOAM PIPING ON THE MAIN DECK IN WAY OF # 3CCARGO TANK(4 PLACES)
Condition: Unknown
Due 28 February 1986
Resolved 20 November 1985
Fire Fighting
Issued 20 November 1985 Resolved
REPLACE DETERIORATED NUTS AND BOLTS IN BOTH THE FOAM AND FIRE MAIN PIPING SYSTEMS ON THE MAIN DECK INCLUDING VALVES,FLANGES AND EXPANSION JOINTS.
Condition: Unknown
Due 28 February 1986
Resolved 20 November 1985
Electrical
Issued 20 November 1985 Resolved
REPAIR EXPLOSION PROOF LIGHTING FIXTURES(2) ON THE PORT SIDE OF DECK STORESENCLOSURE ON THE MAIN DECK.
Condition: Unknown
Due 20 November 1985
Resolved 20 November 1985
Engineering
Issued 20 November 1985 Resolved
REMOVE OIL FROM PUMP ROOM BILGES
Condition: Unknown
Due 28 February 1986
Resolved 20 November 1985

Ownership record