Records from 1984 to 1991. Most recent: inspection, 15 July 1991.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 8
15 July 1991
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1250457
1 May 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 330221
1 May 1989
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1032996
27 January 1988
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 321068
27 January 1988
MARPOL Annex I Examination · Certificate of Compliance
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1023212
10 October 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 312056
10 October 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1013383
30 November 1984
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 302554
Navigation
Issued 15 July 1991
Resolved
Update charts prior to return port of Philadelphia.
Condition: Unknown
Due 15 July 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 15 July 1991
Resolved
CARGO TANK TOPS LEAK AT COVER OF #4,6, AND 8. PERMANENT REPAIRS ARE TO BE MADE PRIOR TO RETURN U.S. PORT. PRESENT OPS ALLOWED PROVIDED POSITIVE PRESSURE IS MAINTAINED ON TANKS DURING ALL CARGO OPS.
Condition: Unknown
Due 15 July 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 15 July 1991
Resolved
Free vent closure on stack deck (03) center aft.
Condition: Unknown
Due 15 July 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 15 July 1991
Resolved
Replace flame screens in vent 01 deck in area of lifeboat and vent next to embarcation ladder starboard side.
Condition: Unknown
Due 15 July 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 15 July 1991
Resolved
Provide mechanical means of closure on fuel/cargo containments throughout the vessel.
Condition: Unknown
Due 15 July 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 27 January 1988
Resolved
REPAIR OR REPLACE DISCHARGE PRESSURE GAUGE FOR EMERGENCY FIRE PUMP,AS REQUIRED.
Condition: Unknown
Due 27 January 1988
Resolved 27 January 1988
Deck/Cargo
Issued 27 January 1988
Resolved
46 CFR 32.53 MAKE PERMANENT REPAIRS TO CRACK IN SCRUBBER HOUSING.
Condition: Unknown
Due 27 January 1988
Resolved 27 January 1988
Deck/Cargo
Issued 27 January 1988
Resolved
MAKE PERMANENT REPAIRS TO PIPING ON GAUGING SYSTEM, AFT OF NO ONE CENTER TANK, ON DECK.
Condition: Unknown
Due 27 January 1988
Resolved 27 January 1988
Navigation
Issued 10 October 1986
Resolved
33USC1231 DID NOT HAVE ONBOARD THE COPY OF THE TIDAL CURRENT 33CFR164.33(A)(2) TABLES REQUIRED BY 33CFR164.33(A)(2).
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Deck/Cargo
Issued 30 November 1984
Resolved
MAKE PROPER REPAIR TO FRACTURED VOID COMPARTMENT LOCATED BETWEEN NR. 9 AND NR. 10 CARGO HATCH (HOLD NR. 5).
Condition: Unknown
Due 30 November 1984
Resolved 30 November 1984
Deck/Cargo
Issued 30 November 1984
Resolved
RENEW WORN FLAME SCREENS ON FUEL OIL SLUDGE TANK VENTS
Condition: Unknown
Due 30 November 1984
Resolved 30 November 1984