Records from 1985 to 1992. Most recent: inspection, 11 November 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 8
11 November 1992
Certificate of Compliance
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 832747
9 November 1992
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 354209
7 June 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 323711
7 June 1988
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1200523
28 November 1986
Certificate of Compliance
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1027903
18 June 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 464964
27 November 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 305748
27 November 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 999686
Navigation
Issued 11 November 1992
Resolved
PROPERLY SECURE RUDDER ANGLE INDICATOR LINKAGE.
Condition: Unknown
Due 22 December 1992
Resolved 22 December 1992
Navigation
Issued 11 November 1992
Resolved
PROPERLY FIT STEERING GEAR MAKE UP HOSES.
Condition: Unknown
Due 22 December 1992
Resolved 22 December 1992
Electrical
Issued 11 November 1992
Resolved
DECK WIRING CONDUIT EXPANSION JOINTS WASTED AND PIPE HOLED. PROVE DECK CABLE RUN INTRINSICALLY SAFE.
Condition: Unknown
Due 22 December 1992
Resolved 22 December 1992
Construction/Loadline
Issued 11 November 1992
Resolved
CRACK BETWEEN #2 CENTER CBT AND #2 PORT CARGO TANK AT 2ND PLATFORM. TEMPORARILY REPAIRED WITH CEMENT. PROVIDE PERMENANT REPAIRS PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 11 January 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 11 November 1992
Resolved
AUXILIARY BOILER BLOW DOWN VALVE OVERBOARD STBD SIDE E/R LEAKING AT SIDE SHELL. TEMPORARILY REPAIRED WITH CEMENT. PROVIDE PERMANENT REPAIRS PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 11 January 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 11 November 1992
Resolved
STEAM VALVE BODY STBD ANCHOR WINDLASS CRANKED AND LEAKING, TEMPORARILY REPAIRED WITH CEMENT. PROVIDE PERMANENT REPAIRS PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 11 January 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 11 November 1992
Resolved
MAIN DECK FUEL BUNKERING LINE EXPANSION JOINTS DISPLACED APPROX. 3/4". PROVE LINE FROM MIDSHIPS MANIFOLD TO AFT.
Condition: Unknown
Due 22 December 1992
Resolved 22 December 1992
Fire Fighting
Issued 11 November 1992
Resolved
PROVIDE BRACKETING FOR DIESEL FIRE PUMP FUEL RETURN LINE.
Condition: Unknown
Due 22 December 1992
Resolved 22 December 1992
Lifesaving
Issued 11 November 1992
Resolved
PRIOR TO NEXT U.S. PORT, REMOVE PRODUCT RESIDUE FROM PUMP ROOM BILGES.
Condition: Unknown
Due 11 January 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 11 November 1992
Resolved
PRIOR TO NEXT U.S. PORT, PERMANTLY REPAIR DECK SEAL DRAIN LINE PRESENTLY_x001C_ FIBERGLASSED.
Condition: Unknown
Due 11 January 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 11 November 1992
Resolved
SECURE LOOSE GEAR IN CARGO PUMP ROOM.
Condition: Unknown
Due 22 December 1992
Resolved 22 December 1992
Electrical
Issued 11 November 1992
Resolved
REPAIR EXPLOSION PROOF LIGHT UPPER LEVEL PUMP ROOM. MAKE INTRINSICALLY SAFE.
Condition: Unknown
Due 22 December 1992
Resolved 22 December 1992