MAURY USCG vessel records Sign in
← All vessels

KAPETAN MICHALIS

KAPETAN MICHALIS is a 1977 tank ship. The Coast Guard has recorded 14 inspections since 1988, most recently in April 2002, along with 2 deficiencies.

Records from 1988 to 2002. Most recent: inspection, 24 April 2002.

Built
1977
Last inspected
24 April 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7376537 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224522
Flag
BERMUDA
—
Maury page id
psix-224522

Inspections, by type

…with no type recorded7
Years with a record 12 calendar years (1988–2002)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it516423 - Dead Weight, Ton
186500 - Convention (Subpart B), Net Ton
247160 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 14

24 April 2002 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1612016
20 April 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 289383
5 February 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 274661
13 October 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 408946
23 August 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 393994
11 July 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 380739
30 April 1994 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1454096
31 January 1993 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1141708
11 January 1992 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 949417
11 November 1990 Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1225170
3 November 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 333593
3 November 1989 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1022626
1 December 1988 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 327168
1 December 1988 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1035543

Deficiency record · 2

Deck/Cargo › Inert Gas System
Issued 24 April 2002 Resolved
Unable to calibrate oxygen analyzer. Vessel granted permission to transfer with following conditions: 1.Maintain live watch of inert gas discharge. 2.Conduct oxygen readings of cargo tanks every 30min and log. 3.Make complete repairs to satisfaction of class prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2002
Resolution: Repairs made to satisfaction of classisfication society. Vessel permitted to leave port.
Construction/Loadline
Issued 13 October 1997 Resolved
Vessel's loadline not contrasting with hull as required. Loadline was barely visible to CG Inspectors._x001C_ Vessel must repair prior to next U.S. port call.
Condition: Unknown
Due 16 February 2000
Resolved 16 February 2000

Ownership record