Records from 1984 to 2001. Most recent: inspection, 8 June 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
8 June 2001
Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 291372
8 June 2001
Tank Vessel Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1068117
5 May 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 415745
5 May 1998
Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375384
23 December 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 398758
22 November 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 385074
21 September 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 651446
20 September 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 863670
9 September 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 370313
9 September 1994
Tank Vessel Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1447392
1 September 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 505553
1 September 1992
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1145562
28 August 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 352835
28 August 1992
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 955524
27 December 1990
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 931062
1 January 1990
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1238483
1 January 1990
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1238759
14 December 1988
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1209910
24 November 1987
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1336184
28 August 1984
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 521304
Construction/Loadline
Issued 9 September 1994
Resolved
THE VESSEL DID NOT HAVE STANDARD DISCHARGE CONNECTION ONBOARD AT THE TIME_x001C_ OF BOARDING. SPECIFIC CITE: 33 C.F.R. 155.430_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 June 1995
Resolved 8 June 1995
Construction/Loadline
Issued 9 September 1994
Resolved
PROVIDE STANDARD DISCHARGE CONNECTION IN ACCORDANCE WITH MARPOL 73/78 REGULATION 19.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Electrical
Issued 9 September 1994
Resolved
LOCATE AND CORRECT ELECTRICAL GROUND INDICATED ON 115VAC SIDE OF EMERGENCY SWITCHBOARD
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Lifesaving
Issued 9 September 1994
Resolved
SERVICE TWO INFLATABLE LIFE RAFTS AND ASSOCIATED HYROSTATIC RELEASE MECHANISMS IN ACCORDANCE WITH SOLAS CHAPTER III REGULATION 19
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Deck/Cargo
Issued 9 September 1994
Resolved
REPAIR AND PROVE OPERATION OF AUDIBLE AND VISUAL ALARM THAT INDICATES LOW WATER PRESSURE OR LOW WATER FLOW RATE TO THE FLUE GAS SCRUBBER IN ACCORDANCE WITH SOLAS 74/78 CHAPTER II-2 REGULATION 62.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Unknown
Issued 14 December 1988
Resolved
REPLACE PRIOR TO BUNKERING OPERATIONS ALL WASTER/HOLED FLAME SCREENS, POINT OUT TO THE CHIEF MATE, IN BUNKER TANK VENTS
Condition: Unknown
Due 14 December 1988
Resolved 14 December 1988
Unknown
Issued 14 December 1988
Resolved
REPLACE ALL WASTED/HOLED FLAME SCREENS IN CARGO PUMPROOM VENTILATION SYSTEMPRIOR TO CARGO TRANSFER.
Condition: Unknown
Due 14 December 1988
Resolved 14 December 1988
Unknown
Issued 14 December 1988
Resolved
REPLACE WITH PROPER MESH SIZE ALL FLAME SCREENS AS NOTED TO THE [name withheld] SHOULD BE 30 X 30 MESH OR DOUBLE 20 X 20 MESH.
Condition: Unknown
Due 14 December 1988
Resolved 14 December 1988