MAURY USCG vessel records Sign in
← All vessels

CHEVRON SOUTH AMERICA

CHEVRON SOUTH AMERICA is a 1976 tank ship. The Coast Guard has recorded 31 inspections since 1986, most recently in October 2002, along with 18 deficiencies — 1 with no resolution recorded — and 1 operational control, 1 with no removal date recorded.

Records from 1986 to 2002. Most recent: inspection, 22 October 2002.

Built
1976
Last inspected
22 October 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7376989 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224539
Flag
UNITED KINGDOM
—
Maury page id
psix-224539

Inspections, by type

…with no type recorded19
…past their stated due date1
Years with a record 16 calendar years (1986–2002)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it413163 - Dead Weight, Ton
162077 - Regulatory (Subpart C or D), Net Ton
198951 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 31

22 October 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1694345
16 July 2002 Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1647402
17 August 2001 Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 293072
17 August 2001 Tank Vessel Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1362396
13 October 2000 Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 284653
19 July 2000 Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 280171
21 July 1999 Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 430975
23 June 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 416820
18 March 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 483296
2 July 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 405340
27 January 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 399626
24 May 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 391511
22 May 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 378540
26 May 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 367235
25 May 1994 Tank Vessel Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1170600
25 February 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1163981
6 December 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 71026
15 July 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 672743
30 June 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 121364
19 April 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 839580
24 March 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 357091
24 March 1993 Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1150167
9 February 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1149054
20 March 1992 Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 956398
8 February 1991 Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1222842
10 January 1990 Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1237299
27 December 1988 Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1344919
23 December 1987 Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1314861
13 February 1987 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 314382
13 February 1987 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1324023
17 April 1986 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 308250

Deficiency record · 18

Operations/Management › Pollution
Issued 16 July 2002 Resolved
NOTED LARGE QUANTITY OF CARGO IN PUMP ROOM. RESULT OF ACCIDENTAL DRAINAGE OF STRAINER. CLEAN BEFORE PUMPS ARE ENERGIZED.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 July 2002
Resolved 16 July 2002
Resolution: ABS Surveyor on regularly scheduled survey verified correction.
Construction/Loadline › Structures
Issued 16 July 2002 No resolution recorded
NOTED 2 OF 3 VENTILATION DUCTS FORWARD AND AT BOTTOM OF MAIN PUMP ROOM TO BE WASTED & BUCKLED. ACTUAL DUCT'S BUCKLED W/ NO FLUSH FACE PIECE FOR SCREEN ATTACHMENT. SCREEN MESH WASTED AND/OR PARTIALLY MISSING AS RESULT OF WASTAGE. CERT. ISSUING AUTH. REPORT MAY BE ACCEPTED IN LIEU OF USCG INSP. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2002 — due date passed with no resolution recorded
Resolution: Rcvd ABS Class rpt M293142 dtd 22OCT02 fm "[name withheld]" clearing def.
Construction/Loadline › Structures
Issued 16 July 2002 Resolved
NOTED (IN PARTICULAR) CARGO TANK HATCHES & ULLAGES VICINITY OF 4-8 STARBOARD TO SHOW SIGNIFICANT SCALE. CLEAN SURFACE AND INVESTIGATE, REPAIR AS NECESSARY. NOTED 2 AREAS THAT INSP. COULD OF EASILY PUNCHED HOLE W/ HAMMER. CERT. AUTHORITY MAY BE ACCEPTED IN LIEU OF USCG INSPECTION.
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 22 October 2002
Resolution: Rcvd ABS rpt #M293142 dtd 22OCT02 fm "[name withheld]" clearing def.
Deck/Cargo
Issued 16 July 2002 Resolved
REPLACE ALL WASTED (PAPER THIN) BLANK FLANGES ON WESO SYSTEM PORTS ON DECK. NOTED NUMEROUS BLANK FLANGES TO BE PAPER THIN AND EASILY HOLED BY CHIPPING HAMMER. MAY BE CLEARED BY CERT. ISSUING AUTH. IN LIEU OF USCG INSPECTOR.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 22 October 2002
Resolution: Rcvd ABS Class rpt dtd 22OCT02 # 293142 fm "[name withheld]" clearing def.
Deck/Cargo
Issued 19 July 2000 Resolved
The high high level alarm must be operational before cargo loading or internal cargo tranfer operation can can be conducted.
Condition: Unknown
Due 28 November 2000
Resolved 28 November 2000
Fire Fighting
Issued 2 July 1997 Resolved
RENEW/REPAIR THE DAMAGED ELECTRICAL CIRCUIT BREAKER FOR THE EMERGENCY FIRE PUMP._x001C_ SEE SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 15 July 1997
Resolved 16 July 1997
Accommodation/Occupational Safety
Issued 24 May 1996 Resolved
RENEW VENT CLOSURE TO BATTERY ROOM. _x001C_ ILLC 66 ANNEX I/19
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Lifesaving
Issued 24 May 1996 Resolved
REPLACE RETRO-REFLECTIVE TAPE ON BOTTOM OF BOTH LIFEBOATS. _x001C_ SOLAS 74 (AMENDED) III/30.2.7
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Fire Fighting
Issued 24 May 1996 Resolved
RENEW DETERIORATED EMERGENCY FIRE PUMP DISCHARGE LINE LOCATED NEAR THE _x001C_ PRESSURE GUAGE IN THE STEERING GEAR ROOM. _x001C_ SOLAS 60 II/56(e)
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Fire Fighting
Issued 24 May 1996 Resolved
RENEW DETERIORATED FIXED FOAM LINE IN ENGINE ROOM, FORWARD AT CENTERLINE._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Engineering
Issued 24 May 1996 Resolved
FREE-UP DIESEL STORAGE TANK REMOTE SHUT OFF VALVE, LOCATED OUTSIDE_x001C_ EMERGENCY GENERATOR ROOM. _x001C_ SOLAS 60 II/69(c)
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Deck/Cargo
Issued 25 February 1994 Resolved
MAKE TEMPORARY REPAIRS TO THE 600mm DIAMETER PIPE LOCATED IN THE #3 CARGO OIL GATHERING PUMP SUCTION STRAINER OUTLET OFFSTICKER AND HYDRO TEST PRIOR TO NEXT U.S. PORT ENTRY. PERMANENT REPAIRS TO BE COMPLETED AT NEXT SCHEDULED DRYDOCKING. _x001C_
Condition: Unknown
Due 25 February 1994
Resolved 25 February 1994
Deck/Cargo
Issued 9 February 1993 Resolved
MAKE PERMANENT REPAIRS TO THE TEMPORARY PATCH ON THE 400MM OFF STICKER ON THE #3 CARGO GATHERING LINE. PRESSURE TEST ANF PROVIDE SUITABLE DOCUMENTED EVIDENCE.
Condition: Unknown
Due 9 February 1993
Resolved 9 February 1993
Unknown
Issued 27 December 1988 Resolved
ALL FLAME SCREENS ON THE INERT GAS MAIN/CARGO TANK VENTING SYSTEM P/V VALVES WHICH ARE CURRENTLY 20 X 20 MESH-SHALL BE REPLACED WITH FLAME SCREENOF 30 X 30 MESH SIZE. THIS ITEM TO BE ACCOMPLISHED PRIOR TO LOADING NEXT CARGO.
Condition: Unknown
Due 27 December 1988
Resolved 27 December 1988
Engineering
Issued 23 December 1987 Resolved
REMOVE EXCESS OIL FROM FORWARD PUMPROOM BILGES
Condition: Unknown
Due 23 December 1987
Resolved 23 December 1987
Engineering
Issued 23 December 1987 Resolved
REPAIR LEAK IN FUEL OIL TRANSFER PUMP IN FORWARD PUMPROOM.
Condition: Unknown
Due 23 December 1987
Resolved 23 December 1987
Engineering
Issued 23 December 1987 Resolved
ENGINEROOM BILGE OILY WATER SEPARATOR NOT FULLY FUNCTIONAL
Condition: Unknown
Due 23 December 1987
Resolved 23 December 1987
Construction/Loadline
Issued 23 December 1987 Resolved
BALLAST OILY WATER MONITOR FOT FUNCTIONING PROPERLY
Condition: Unknown
Due 23 December 1987
Resolved 23 December 1987

Ownership record