Records from 1984 to 1994. Most recent: inspection, 3 June 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
3 June 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 534789
2 November 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 671002
14 August 1993
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 842788
28 July 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 87146
21 July 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 159522
19 July 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 359500
19 July 1993
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1155068
20 August 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 345357
19 August 1991
Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 940486
24 August 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 338948
24 August 1990
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1231768
13 August 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 332000
13 August 1989
Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1205859
2 February 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 459899
5 July 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 324265
5 July 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 896457
18 September 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 531256
13 January 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 313800
13 January 1987
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1317153
11 September 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 304169
11 September 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 992982
20 February 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 530591
9 February 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 300141
29 May 1984
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 296439
Accommodation/Occupational Safety
Issued 19 July 1993
Resolved
A VIO OF 33 CFR 151.63 IN THAT THE VESSELS MASTER COULD NOT PROVE PROPER DISPOSAL OF GARBAGE. PLASTICS WERE FOUND IN FOOD WASTE THAT WAS TO BE DISCHARGED TO SEA. VESSELS CREW NOT FOLLOWING WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 19 July 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 19 July 1993
Resolved
A VIO OF 33 CFR 164.33 IN THAT U.S. CHARTS #12311, 12312, AND 12304, USED BY THE VESSEL WERE NOT CORRECTED TO NTM 23/93, WHICH WERE REASONABLY
Condition: Unknown
Due 20 July 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 19 July 1993
Resolved
PRIOR TO NEXT U.S PORT, REPAIR LEAK AT HATCH ON 2 CENTER CARGO TANK.
Condition: Unknown
Due 18 August 1993
Resolved 18 August 1993
Deck/Cargo
Issued 19 July 1993
Resolved
REPAIR PORT EXHAUST FAN SHAFT NOT LATER THAN 30SEP93.
Condition: Unknown
Due 18 August 1993
Resolved 18 August 1993
Construction/Loadline
Issued 19 July 1993
Resolved
PRIOR TO DEPARTING PORT OF PHILADELPHIA PROVIDE CLASSIFICATION SOCIETY REPORT WITH RECOMMENDATIONS ON REPAIR AND OR CONDITIONS OF OPERATION ATTESTING TO THE 4 CRACKS IN 3 CENTER BALLAST TANK.
Condition: Unknown
Due 21 July 1993
Resolved 27 July 1993
Deck/Cargo
Issued 19 July 1993
Resolved
PRIOR TO NEXT U.S. PORT MAKE BUZZER ALARM ON IGS SYSTEM OPERATIONAL. UNTIL REPAIRS ARE MADE ALARM PANEL IS TO BE MANNED DURING IGS OPERATION.
Condition: Unknown
Due 21 July 1993
Resolved 27 July 1993
Fire Fighting
Issued 19 July 1993
Resolved
PRIOR TO CARGO OR BUNKER OPERATIONS, PROVIDE COPY OF RECEIPT FOR NEW FIRE NOZZLES AND PROVIDE PROOF NOZZLES WERE PLACED ON STATION.
Condition: Unknown
Due 19 July 1993
Resolved 27 July 1993
Deck/Cargo
Issued 19 July 1993
Resolved
PRIOR TO NEXT U.S. PORT REPAIR/REPLACE FLAME VENT SCREENS ON ALL BUNKER VENTS.
Condition: Unknown
Due 21 July 1993
Resolved 27 July 1993
Electrical
Issued 19 July 1993
Resolved
PRIOR TO DEPARTING THE PORT OF PHILADELPHIA MAKE FOWARD MAST SWITCH EXPLOSION PROOF.
Condition: Unknown
Due 21 July 1993
Resolved 27 July 1993
Navigation
Issued 24 August 1990
Resolved
VESSELS N.O.S. CHARTS 18720,18740,18746,18749, & 18751 WERE NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33(a)(1)(ii).
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Electrical
Issued 24 August 1990
Resolved
PROVIDE ELECTRICAL MATTING IN FRONT OF AND IN BACK OF ENGINE ROOM SWITCH- BOARDS PRIOR TO ENTRY INTO NEXT U.S. PORT OF CALL.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Electrical
Issued 24 August 1990
Resolved
INSTALL PROPER STUDS IN EXPLOSION PROOF LIGHT FIXTURES WHERE MISSING AND TIGHTEN ALL STUDS WHERE LOOSE IN THE CARGO PUMP ROOM, PAINT LOCKER, AND ALLAREAS WHERE REQUIRED PRIOR TO CARGO OPERATIONS OR BUNKERS.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Construction/Loadline
Issued 24 August 1990
Resolved
PROVE PROPER OPERATION OF ENGINE ROOM EMERGENCY BILGE EJECTION VALVE PRIOR TO ENTRY INTO NEXT U.S. PORT OF CALL.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Deck/Cargo
Issued 24 August 1990
Resolved
PROVIDE CALIBRATION GAS FOR EXPLOSION METER PRIOR TO ENTRY INTO NEXT U.S. PORT OF CALL.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Deck/Cargo
Issued 24 August 1990
Resolved
INSTALL METALLIC MECHANICAL PLUGS IN ALL FUEL VENT CONTAINMENTS PRIOR TO ENTRY INTO NEXT U.S. PORT OF CALL.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990