MAURY USCG vessel records Sign in
← All vessels

FALCON

FALCON is a 1976 tank ship. The Coast Guard has recorded 11 inspections since 1987, most recently in October 1998, along with 10 deficiencies and 1 operational control.

Records from 1987 to 1998. Most recent: inspection, 20 October 1998.

Built
1976
Last inspected
20 October 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7377373 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224553
Flag
MARSHALL ISLANDS
—
Maury page id
psix-224553

Inspections, by type

…with no type recorded5
Years with a record 7 calendar years (1987–1998)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it284090 - Dead Weight, Ton
106123 - Convention (Subpart B), Net Ton
138601 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

20 October 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 421601
18 March 1997 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1097532
14 March 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 401608
29 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1192290
10 March 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 376253
10 March 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 837365
23 March 1992 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 952317
2 February 1991 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 932974
19 January 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 335233
19 January 1990 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1210870
24 December 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 320607

Deficiency record · 10

Deck/Cargo
Issued 14 March 1997 Resolved
#2 CARGO PUMP EMERGENCY SHUTDOWN INOPERATIVE.
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Navigation
Issued 14 March 1997 Resolved
SOUND POWERED PHONE IN TURBINE FLAT INOPERATIVE.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Electrical
Issued 14 March 1997 Resolved
EMERGENCY GENERATOR AUTOSTART INOPERATIVE.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Construction/Loadline
Issued 14 March 1997 Resolved
15 PPM MONITOR AND ALARM FOR ENGINEROOM OILY WATER SEPARATOR INOPERATIVE.
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Deck/Cargo
Issued 14 March 1997 Resolved
#4 CARGO PUMP EMERGENCY SHUTDOWN INOPERATIVE.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Fire Fighting
Issued 14 March 1997 Resolved
HOLE IN MAIN FIRE LINE.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Fire Fighting
Issued 14 March 1997 Resolved
REMOTE START FOR EMERGENCY FIRE PUMP INOPERATIVE.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Documentation
Issued 14 March 1997 Resolved
SOPEP APPROVAL LETTER DOES NOT REFERENCE PLAN ABOARD VESSEL.
Condition: Unknown
Due 14 April 1997
Resolved 18 March 1997
Construction/Loadline
Issued 10 March 1995 Resolved
FRACTURE IN WELD JOINT. SEE PSNS
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Documentation
Issued 24 December 1987 Resolved
OIL RECORD BOOK HAD NO RECORD OF OIL RESIDUE DISPOSAL SINCE JUNE 1986 TANK TO TANK TRANSFER ENTRIES ARE REQUIRED
Condition: Unknown
Due 24 December 1987
Resolved 24 December 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.