MAURY USCG vessel records Sign in
← All vessels

YELLOW STAR

YELLOW STAR is a 1975 tank ship. The Coast Guard has recorded 46 inspections since 1985, most recently in December 1995, along with 23 deficiencies.

Records from 1985 to 1995. Most recent: inspection, 9 December 1995.

Built
1975
Last inspected
9 December 1995
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7377426 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224556
Flag
NORWAY
—
Maury page id
psix-224556

Inspections, by type

…with no type recorded34
Years with a record 11 calendar years (1985–1995)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it42458 - Dead Weight, Ton
12494 - Regulatory (Subpart C or D), Net Ton
23721 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 46

9 December 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 385651
27 September 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 383497
8 November 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 534574
27 September 1994 MARPOL Annex I Examination · Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1387612
28 August 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 369912
15 August 1994 Tank Vessel Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1177259
8 March 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 458732
16 February 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 646697
15 February 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 500578
31 December 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 363338
9 November 1993 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1135322
24 August 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 360419
24 August 1993 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1428251
12 July 1993 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 44116
26 February 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 452116
26 January 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 57592
26 January 1993 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 830449
5 October 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 518316
5 October 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1258970
11 August 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 481900
11 August 1992 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1250142
25 February 1992 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 646687
20 February 1992 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 501565
16 January 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 348153
24 September 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 522431
4 March 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 342257
4 March 1991 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 931793
4 March 1991 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 946392
28 December 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 482829
12 March 1990 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 909106
1 February 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 335102
23 January 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 491755
14 January 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1223013
9 January 1990 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 906645
11 July 1989 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 514901
6 December 1988 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 327207
6 December 1988 Certificate of Compliance
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1209117
27 May 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 502782
27 November 1987 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 319830
27 November 1987 Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1309516
12 January 1987 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 313724
22 August 1986 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 452326
19 February 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1306195
18 February 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 463735
29 August 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 446913
5 February 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 300164

Deficiency record · 23

Navigation
Issued 27 September 1995 Resolved
VESSEL IS TO SWING COMPASS IN ORDER TO PROVIDE AN UPDATED DEVIATION CARD (LAST ONE DATED JAN95 WITH LAST D/D IN MAY 95). TO BE DONE PRIOR TO ARRIVAL AT NEXT U.S. PORT.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Navigation
Issued 27 September 1995 Resolved
VESSEL IS TO PROVIDE VOLUME "J" LIGHT LIST FOR THE GALVESTON BAY AREA. TO BE COMPLETED PRIOR TO VESSEL DEPARTING FROM GALVESTON.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Accommodation/Occupational Safety
Issued 15 August 1994 Resolved
PRIOR TO NEXT U.S. PORT VISIT, CLEAN/REPAIR GALLEY VENT SCREEN IN WAY OF TOP GRILL.
Condition: Unknown
Due 15 September 1994
Resolved 15 September 1994
Fire Fighting
Issued 15 August 1994 Resolved
NEXT U.S. VOYAGE, PROVIDE COPY OF FOAM ANALYSIS TO LOCAL U.S. COAST_x001C_ GUARD.
Condition: Unknown
Due 15 September 1994
Resolved 15 September 1994
Documentation
Issued 15 August 1994 Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE PROPER DOCUMENTATION OR APPROVAL NUMBER FOR MARINE SANITATION DEVICE TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 15 September 1994
Resolved 15 September 1994
Navigation
Issued 15 August 1994 Resolved
PRIOR TO NEXT U.S. PORT VISIT, CLEARLY LABEL STEERING FAILURE LIGHTS.
Condition: Unknown
Due 15 September 1994
Resolved 15 September 1994
Fire Fighting
Issued 15 August 1994 Resolved
REPLACE BAD FIRE HOSES ON FORWARD FIRE STATION.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Fire Fighting
Issued 15 August 1994 Resolved
MAKE REPAIRS TO PORT AFT CARGO DECK FIRE MONITOR FOR PROPER OPERATION.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Documentation
Issued 15 August 1994 Resolved
NEXT U.S. VOYAGE, PROVIDE COPY OF CLASS SOCIETY CORRECTION TO IOPP CERTIFICATE FORM B IN REGARDS TO SBT AND CBT (REGULATION 13) TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 15 August 1994
Resolved 15 August 1994
Accommodation/Occupational Safety
Issued 15 August 1994 Resolved
PRIOR TO NEXT U.S. VOYAGE, FIX/REPAIR PIPING FOR SUPPLY OF SHOWER WATER IN HOSPITAL.
Condition: Unknown
Due 15 September 1994
Resolved 15 September 1994
Navigation
Issued 15 August 1994 Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE VISUAL ALARMS ON BRIDGE FOR STEERING LOSS OF POWER AND LOW HYDRAULIC LEVEL AS PER SOLAS II - 1129.12.2.
Condition: Unknown
Due 15 September 1994
Resolved 15 September 1994
Lifesaving
Issued 15 August 1994 Resolved
MAKE REPAIRS TO HOLED VENT PIPE FROM PAINT LOCKER.
Condition: Unknown
Due 15 September 1994
Resolved 15 September 1994
Construction/Loadline
Issued 24 August 1993 Resolved
Recalibrate ballast monitor system to meet new MARPOL requirements for 30l/nm alarm set point, and prove proper operation._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 August 1993
Resolved 24 August 1993
Construction/Loadline
Issued 24 August 1993 Resolved
Make a mid-body ballast tank available for inspection. The tank must be certified safe for entry by a marine chemist.
Condition: Unknown
Due 24 August 1993
Resolved 24 August 1993
Fire Fighting
Issued 26 January 1993 Resolved
MAKE PERMANENT REPAIRS TO FOAM MAIN IN THE PRESENCE OF CLASSIFICATION SOCIETY. PROVIDE REPORT FROM CLASSIFICATION SOCIETY UPON COMPETION OF REPAIRS. VESSEL MAY NOT CONDUCT ANY TRANSFER OPERATIONS. VESSEL MAY NOT DEPART ANCHORAGE UNTIL THIS REQUIREMENT HAS BEEN SATISFIED.
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Construction/Loadline
Issued 9 January 1990 Resolved
PRIOR TO RETURNING TO US WATERS THE VESSEL MUST REPLACE ALL FIBERGLASS BUTTERWORTH HATCH COVERS WITH STEEL HATCH COVERS.
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Fire Fighting
Issued 9 January 1990 Resolved
PRIOR TO DEPARTURE OF THE PORT OF PHILADELPHIA VESSEL MUST HAVE ON BOARD FOUR COMPLETE FIREMAN'S OUTFITS.THE VESSEL IS MISSING ON FIREMANS SUIT.
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Deck/Cargo
Issued 6 December 1988 Resolved
DETERIORATED PORT & STBD FIXED BUNKER CONTAINMENT PANS, BOTH FORWARD OF DECKHOUSE/CARGO PUMP ROOM.
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Fire Fighting
Issued 6 December 1988 Resolved
FIRE STATION HYDRANT VALVE ON VESSEL'S MAIN DECK STERN, IS LEAKING SEAWATERWHEN THE FIRE MAIN SYSTEM IS CHARGED.
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Deck/Cargo
Issued 6 December 1988 Resolved
CRACK IN GEAR BOX BUTTERFLY VALVE, FOR NO.1 CARGO LINE SYSTEM, LOCATION MAIN DECK, STBD SIDE, ADJACENT TO CARGO TANK 4S.
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Fire Fighting
Issued 6 December 1988 Resolved
FIRE STATION HYDRANT VALVE, IN LOWER CARGO PUMP ROOM IN FROZEN, VALVE CANOTBE OPEN, FIRE HOSE CANOT BE CONNECTED.
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Fire Fighting
Issued 6 December 1988 Resolved
FIRE STATION FOAM MONITOR, IS LEAKING FIREMAIN SEAWATER, MONITOR LOCATED STBD SIDE, AFT, FORWARD OF CARGO PUMP ROOM.
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Accommodation/Occupational Safety
Issued 27 November 1987 Resolved
33 CFR 159.7(C) THE VESSEL WAS NOT EQUIPPED WITH AN OPERABLE TYPE I, II, OR III MARINE SANITATION DEVICE (I.E. THE TYPE II MSD ON BOARD THE VESSEL WAS BEING USED WITH IMPROPER CHEMICALS).
Condition: Unknown
Due 27 November 1987
Resolved 27 November 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.