MAURY USCG vessel records Sign in
← All vessels

CAPE RISE

CAPE RISE is a 1977 freight ship. The Coast Guard has recorded 117 inspections since 1985, most recently in October 2025, along with 162 deficiencies, 3 operational controls, 1 with no removal date recorded and 10 casualty investigations between 2009 and 2023.

Records from 1985 to 2025. Most recent: inspection, 8 October 2025.

Built
1977
Last inspected
8 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7530808 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224578
Flag
SAUDI ARABIA
366839000 (licence lapsed)
Maury page id
psix-224578

Inspections, by type

…with no type recorded45
Years with a record 36 calendar years (1985–2025)
The 117 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)594.6 ft × 105.6 ft × 65.1 ft
Registered tonnagegross 31,236 / net 9,370
ITC dimensions (L × B × D)594.6 ft × 105.6 ft × 65.1 ft
ITC tonnagegross 31,236 / net 9,370
BuilderKAWASAKI HEAVY INDUSTRIES · SAKAIDE, JAPAN · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORFOLK, VA
Trade endorsementsRegistry
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31236 - Convention (Subpart B), Gross Ton
9370 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

KAFGMMSI 366839000 · expired · compulsorily equipped · granted 9 December 1993, cancelled 9 December 1998
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 117

8 October 2025 Appeal
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8251479
30 September 2025 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8243597
31 July 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8199394
10 July 2024 Re-Inspection · ACP COI Oversight · Administrative Inspection · ACP Drydock Oversight · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7954838
14 June 2024 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8020617
2 February 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7861578
12 November 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7830255
3 November 2023 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7820244
2 November 2023 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7819845
30 October 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7816712
27 October 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7816746
19 October 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7811343
16 October 2023 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7929397
6 October 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7807012
14 September 2023 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7791242
2 July 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7744320
2 July 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7820619
26 June 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7723369
25 June 2023 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7726980
30 May 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7700866
2 May 2023 ACP Additional Oversight – Risk Assessment · Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7678819
3 November 2022 ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7587449
3 November 2022 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7590430
28 July 2022 Periodic Inspection · ACP Additional Oversight – Risk Assessment · ACP Periodic Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7517194
5 October 2021 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7326163
25 August 2021 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7295434
22 February 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7144116
3 November 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7088976
13 October 2020 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7075855
18 June 2019 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6719559
10 June 2019 ACP Drydock Oversight · Re-Inspection · ACP COI Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6759672
29 September 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6551308
28 September 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6550173
4 September 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6548471
23 August 2018 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6519996
10 October 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6291745
2 October 2017 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6279257
4 May 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6138332
8 December 2016 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6055383
27 October 2016 MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6033793
19 October 2015 ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5743013
17 August 2014 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4957048
16 August 2014 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4965349
15 August 2014 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4965827
11 August 2014 Administrative Inspection · MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4951226
15 September 2010 ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3849835
1 April 2009 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3444352
26 March 2009 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3440769
25 August 2008 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3305787
25 July 2008 Annual Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3285040
17 October 2007 ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3081027
21 September 2006 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2784602
11 August 2006 ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2764143
10 August 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2743082
10 August 2005 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2478429
19 May 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2362265
27 October 2004 Deficiency Check · MTSA/ISPS Verification
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2229351
19 October 2004 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2224106
6 August 2004 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2168505
23 June 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2108087
3 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2087501
28 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995714
6 May 2003 Periodic Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1787627
30 January 2003 Administrative Inspection · Damage Survey · Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1742951
21 January 2003 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1733090
5 December 2002 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1714983
29 July 2002 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1653463
14 June 2001 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1425167
15 September 2000 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1406787
9 June 2000 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 818893
1 June 2000 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1050768
3 April 2000 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1047379
7 March 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1049178
27 January 2000 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 814349
15 December 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 812914
22 October 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1466068
31 July 1999 Re-Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1470229
18 August 1998 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1131943
4 August 1998 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1368823
17 April 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 789790
5 March 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 783906
6 January 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1107959
4 December 1997 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 776721
22 September 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1113338
9 September 1997 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1470698
18 June 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 776335
15 January 1997 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1100445
7 October 1996 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1147962
26 September 1996 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1141933
20 September 1996 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1133781
10 September 1996 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 228469
29 August 1996 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1428675
17 April 1996 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1080989
1 December 1995 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 872584
21 November 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1188074
19 September 1995 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1452072
3 August 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 220976
10 November 1994 Initial Certification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1448599
15 June 1994 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1020092
3 May 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1016842
14 April 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 357561
16 November 1991 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 347171
10 September 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 345863
9 September 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 346091
4 May 1991 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 343577
4 April 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 350402
3 April 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 336237
10 December 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 327344
11 August 1988 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 325042
29 March 1988 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 439423
28 December 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 505545
19 August 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 317983
20 April 1987 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 449672
12 August 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 310807
12 December 1985 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 496805
27 August 1985 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 460834
28 January 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 300104

Deficiency record · 162

07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 30 September 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Cargo dampers number 29 and 30 did not close when actuated. Rectify prior to the carriage of cargo. 74 SOLAS (Con. Ed. 20’) I/11(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2025
Resolution: Received ABS report accepting deficiency.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 30 September 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Electrical hazard in shower room 02-20 found overhead light fixture hanging by electrical cable and secured to overhead with painter's tape. 74 SOLAS (Con. Ed. 20’) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 6 October 2025
Resolution: Received ABS report accepting deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 September 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Number 29 and 30 cargo dampers on the would not close when actuated. Drying room 02-36 found with wooden storage shelves, cleaning supplies, and cardboard boxes next to an electric radiator. 74 SOLAS (Con. Ed. 20’) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 6 October 2025
Resolution: Received ABS report accepting deficiency.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 September 2025 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. Pipe room 01-10 bulkhead that is connected to a passageway is designated as an A-class division and found with a deteriorated fire-proof cable penetration seal and numerous holes in bulkhead. 74 SOLAS (Con. Ed. 20’) II-2/14.2.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 6 October 2025
Resolution: Received ABS report accepting deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 30 September 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Focsle deck ventilation closure near centerline was found with deformed gasket. 74 SOLAS (Con. Ed. 20’) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 6 October 2025
Resolution: Received ABS report accepting deficiency.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 30 September 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. CGMI observed holes in the boiler flat deck near the auxiliary boiler and over the port engine #1 lube oil cooler. 74 SOLAS (Con. Ed. 20’) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 6 October 2025
Resolution: Received ABS report accepting deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The control air lines were temporarily repaired with a soft patch on the #4 cylinder on the STBD MDE and #5 cylinder on the port MDE. 74 SOLAS (Con. Ed. 20’) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 6 October 2025
Resolution: Received ABS report accepting deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 September 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. CGMI observed a fuel leak on the #2 cylinder fuel pump on the #2 ship service diesel generator. 705 = Prior to operation of the #2 SSDG. 74 SOLAS (Con. Ed. 20’) I/11(a)
Action required: 705 - Other - as specified
Resolved 6 October 2025
Resolution: Received ABS report accepting deficiency.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 30 September 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The public address system is not audible in the engine control room when the MDE or SSDGs are running. 74 SOLAS (Con. Ed. 20’) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 6 October 2025
Resolution: Received ABS report accepting deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The level indicator cap for the bilge water holding tank is missing creating an electrical hazard. 74 SOLAS (Con. Ed. 20’) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 6 October 2025
Resolution: Received ABS report accepting deficiency.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 30 September 2025 Resolved
Any discharge into the sea of oil or oily mixtures from ships of 400 GT and above shall be prohibited except when the ship is proceeding en route. Records observed in the oil record book show multiple OWS discharges from the ER oily bilge tank have occurred while dockside in the Sector Virginia COTP zone. Discharges took place on 28AUG25, 18SEP25 and 19SEP25 totaling 21.8 m3 of OWS effluent. 705 = The discharge of OWS effluent when the vessel is not en route as defined by MARPOL Annex I interpretation 28 in the Sector Virginia COTP Zone is prohibited. MARPOL Annex I/15.2.1/705ac
Action required: 705 - Other - as specified
Resolved 17 November 2025
Resolution: Deficiency was appealed. Denied by OCMI and operator accepted it. Company rescinded deviation from SMS. Uploaded objective evidence to the inspection activity.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 30 September 2025 Resolved
The company should establish procedures, plans and instructions, including checklists, as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. The company currently has a letter of deviation directly violating MARPOL Annex I, Regulation 15 authorizing the discharge of OWS effluent dockside while moored in Portsmouth, VA. Discharges took place on 28AUG25, 18SEP25 and 19SEP25. The company’s letter of deviation authorizes a deviation from QPOL-008, use of oily water separator. The letter of deviation is stated to be in accordance with QMS-029, para 4.6, internal to the company’s safety management system. 74 SOLAS (Con. Ed. 20’) IX/3.1 & ISM Code Regulation 7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2025
Resolved 17 November 2025
Resolution: Deficiency was appealed. Denied by OCMI and operator accepted it. Company rescinded deviation from SMS. Uploaded objective evidence to the inspection activity.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 November 2023 Resolved
Subject to the provisions of regulation 4 of this annex and paragraphs 2, 3, and 6 of this regulation, any discharge into the sea of oil or oily mixtures from ships shall be prohibited. Vessel is reporting their stern tube is discharging its oil lubricant into the environment. Vessel shall make temporary repairs to the satisfaction of the marine inspector prior to movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 4 November 2023
Resolved 6 November 2023
Resolution: Rcvd report from divers that the leak had been secured. Report uploaded.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 2 November 2023 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Multiple seawater leaks found in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 November 2023
Resolution: Received confirmation from ABS that this item was addressed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 November 2023 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Multiple oil leaks found on both MDEs and SSDGs contributing to significant oil accumulation throughout engine room and bilges. Repair multiple MDE and SSDG components by next scheduled drydock.
Action required: 705 - Other - as specified
Resolved 27 November 2023
Resolution: ABS finding number 1343 assigned to this item.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 November 2023 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Remove excess oil accumulation throughout engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 November 2023
Resolution: Rcvd report from ABS this was rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 November 2023 Resolved
Periodic tests and inspections shall be made of the main and auxiliary machinery, boilers, and other equipment. Vessel is not using the latest revision of PSTPs.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 November 2023
Resolution: Received confirmation from ABS that this item was addressed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 November 2023 Resolved
All required fire detection systems shall be capable of automatically indicating the presence or indication of fire and its location. Smoke detector panel on bridge indicates multiple faults.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 November 2023
Resolution: Received confirmation from ABS that this item was addressed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 November 2023 Resolved
Where provision is made for the injection of gas for fire-extinguishing purposes, the necessary pipes for conveying the gas shall be provided with control valves or cocks so marked as to indicate clearly the compartments to which the pipes are led. CO2 control station missing operating instructions and are marked with the incorrect time delay.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 November 2023
Resolution: Received confirmation from ABS that this item was addressed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 November 2023 Resolved
In machinery spaces, two means of escape, one of which may be a watertight door, shall be provided from each engine room. Escape ladder located in aft shaft alley found to have been removed. SOLAS (20) II-2/53(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 November 2023
Resolution: Received confirmation from ABS that this item was addressed.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 2 November 2023 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Vent closures on cargo deck indicated missing gaskets.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 November 2023
Resolution: Received confirmation from ABS that this item was addressed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 November 2023 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. EEBD located in CO2 control room had low pressure.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 November 2023
Resolution: Received confirmation from ABS that this item was addressed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 November 2023 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Galley hood vent on deck has excessive oil/grease build up.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 November 2023
Resolution: Received confirmation from ABS that this item was addressed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 October 2023 Resolved
Vessel experienced loss of both main engines while transiting at sea. Vessel shall arrange class attendance and submit report of inspection/survey attesting to efficacy of repairs and operational tests. Tug escort required while transiting within Sector Puget Sound Captain of the Port Zone. 46 CFR 71.40
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2023
Resolved 27 November 2023
Resolution: See class report dated 27nov2023 in vessel documents
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Water was found in the start air for the #1 and #2 SSDGs affecting the start and stop solenoids. #1 SSDG was inoperable. 74SOLAS(20)I/11(a)
Action required: 60 - Rectify deficiencies prior to movement
Due 3 November 2022
Resolved 14 November 2022
Resolution: Accepted as a Condition of ACS.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. The #3 breaker panel (04-5 Lockers) located on the bridge had multiple openings. 74 SOLAS (20 Cons) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2022
Resolved 14 November 2022
Resolution: Accepted as a Condition of ACS.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 3 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. A hole was found on the exterior vent leading into the hospital room. 74 SOLAS (20 Cons) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2022
Resolved 14 November 2022
Resolution: Accepted as a Condition of ACS.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 3 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. The gyro repeaters on the bridge and in the steering gear room had a difference of 5 degrees. 74 SOLAS (20 Cons) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 3 November 2022
Resolution: O/O corrected on the spot
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. A dead end wire was found topside on the stbd main trailer deck above the ballast water control room. 74 SOLAS (20 Cons) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2022
Resolved 14 November 2022
Resolution: Accepted as a Condition of ACS.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 3 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Multiple wasted lines were found with soft patches topside of tank top deck and the deck above the tank top deck. 74 SOLAS (20 Cons) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2022
Resolved 14 November 2022
Resolution: Accepted as a Condition of ACS.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 3 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. An air leak was found in a line on the port topside of the tank top deck. 74 SOLAS (20 Cons) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2022
Resolved 14 November 2022
Resolution: Accepted as a Condition of ACS.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. A junction box for security lighting IVO the stbd side lifeboat was found unattached with wasted railings. 74 SOLAS (20 Cons) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2022
Resolved 14 November 2022
Resolution: Accepted as a Condition of ACS.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. A Class 1/Div 1 light in the paint locker was found with no seal, allowing intrinsically safe cables to be pulled in and out of explosion proof containment. 74 SOLAS (20 Cons) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2022
Resolved 14 November 2022
Resolution: Accepted as a Condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 November 2022 Resolved
Firefighting systems and appliance shall be kept in good working order and readily available for immediate use. A pin hole leak was found in the fire main station IVO station 38. 74 SOLAS (20 Cons) II-2/14.2.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2022
Resolved 14 November 2022
Resolution: Accepted as a Condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 November 2022 Resolved
Firefighting systems and appliance shall be kept in good working order and readily available for immediate use. Fire suppression bottle used in fixed fire suppression system located in the galley was not charged. 74 SOLAS (20 Cons) II-2/14.2.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2022
Resolved 14 November 2022
Resolution: Accepted as a Condition of ACS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Hydraulic fluid reservoir for #1 and #2 steering pumps and the hydraulic storage tank in the aft steering gear compartment were low. 74SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 14 November 2022
Resolution: Accepted as a Condition of ACS.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Potable water piping in bow thruster room found to be rusting. 74SOLAS(20) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 14 November 2022
Resolution: Accepted as a Condition of ACS.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Bilge high water alarm wiring in bow thruster room improperly installed. 74SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 14 November 2022
Resolution: Accepted as a Condition of ACS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Vessel crew was unable to conduct the following automation testing in accordance to approved automation test procedures: #1 and #2 auxiliary generator high jacket water temp, low lube oil pressure and reverse power relay. 74SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 14 November 2022
Resolution: Accepted as a Condition of ACS.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 November 2022 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Dead end wires and cables were located on forward bulkhead of bow thruster room and in the forward lower level of engine room IWO the main fire pump. 74SOLAS(20)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 14 November 2022
Resolution: Accepted as a Condition of ACS.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 July 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found the emergency generator did not auto-load as designed. SOLAS 74 (2020 Con. Ed.) I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 28 July 2022 Resolved
Firefighting systems and appliances shall be kept in good working order and readily available for immediate use. Found emergency fire pumps priming pump not operating as designed and overheating when operated. SOLAS 74 (2020 Con. Ed.) II-2/14.2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 July 2022 Resolved
The fire detection and fire alarm system shall be kept in good order so as to ensure their required performance if a fire occurs. The display panel for the cargo hold fixed fire detection system had six error messages for different locations throughout the cargo spaces. SOLAS 74 (2020 Con. Ed.) II-2/14.2.1.1.2
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 July 2022 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order to ensure their required performance. Identified several fire doors on 03 deck and 02 deck leading to the stairway not latching the fire division as designed. SOLAS 74 (2020 Con. Ed.) II-2/14.2.1.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 7 September 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 July 2022 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order to ensure their required performance. Identified the galley fire curtain was not sealing the fire division as designed. The fire curtain has an approx. 1/2' gap after latching closed. SOLAS 74 (2020 Con. Ed.) II-2/14.2.1.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 7 September 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 July 2022 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order to ensure their required performance. Identified the galley door was not sealing the fire division as designed. The galley door has an intermittent working lock stuck in the locked position, preventing the door from closing and latching. SOLAS 74 (2020 Con. Ed.) II-2/14.2.1.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 7 September 2022
Resolution: Accepted as a condition of ACS.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 28 July 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found a soft patch on the starboard side deck drain in the fan room. SOLAS 74 (2020 Con. Ed.) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2022
Resolved 7 September 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 28 July 2022 Resolved
On all ships, within the machinery spaces, emergency escape breathing devices shall be situated ready for use at easily visible places, which can be reached quickly and easily at any time in the event of a fire. The number and location of these devices shall be indicated in the fire control plan required by regulation 15.2.4. Found various EEBDs throughout the EDG and bow thruster spaces not stored in proper locations, in brackets, or labeled. SOLAS 74 (2020 Con. Ed.) II-2/13.4.3.1 II-2/13.4.3.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2022
Resolved 7 September 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 28 July 2022 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good order to ensure their required performance. Found multiple port side cargo hold fire dampers inoperable. SOLAS 74 (2020 Con. Ed.) II-2/14.2.1.1.1
Action required: 10 - Deficiency Rectified
Due 28 July 2022
Resolved 28 July 2022
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 5 October 2021 Resolved
Lifesaving appliances and arrangements shall be approved by the Administration. Lifeboat thermal protective aids are not CG approved. 74 SOLAS (97) III/4.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2021
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 5 October 2021 Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed to sea without danger to the ship or persons aboard. The cargo ventilation damper (upper trailer deck stbd forward) air supply regulator valve is damaged and the air supply line is holed and leaking. 74 SOLAS (20) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2021
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 5 October 2021 Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed to sea without danger to the ship or persons aboard. The cargo ventilation damper air control regulator valve (upper trailer deck port side forward) has been replaced with a ball valve. Repair to OEM specifications or replace original regulator valve in kind. 74 SOLAS (20) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2021 Resolved
After any survey of the ship has been completed, no change shall be made in the machinery, equipment and other items covered without the sanction of the Administration. Space heaters were found hard wired into motor controllers for the No. 1 hot water circulating pump, the oil hydraulic pump for mooring winch and capstan, and oil hydraulic pump for mooring winch auto tension. 74 SOLAS (20) I/11(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2021
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 5 October 2021 Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed to sea without danger to the ship or persons aboard. The gyrocompass repeaters and magnetic compass show a disparity of 23 degrees. 74 SOLAS (20) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 October 2021 Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed to sea without danger to the ship or persons aboard. The starboard bilge eductor piping in the steering gear room is missing. 74 SOLAS (20) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 October 2021 Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed to sea without danger to the ship or persons aboard. The No. 1 steering gyro pump is leaking hydraulic fluid. 74 SOLAS (20) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 October 2021 Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed to sea without danger to the ship or persons aboard. The bow thruster space bilge alarm is not permanently mounted and hanging from wire ties. 74 SOLAS (20) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 October 2021 Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed to sea without danger to the ship or persons aboard. The hand pump for the bow thruster is leaking hydraulic fluid and collecting in the bilge. 74 SOLAS (20) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 October 2021 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations shall be kept in good order so as to ensure their required performance if a fire occurs. Multiple cable transits in bridge deck and electrical space have been disturbed and need repaired to OEM specs. 74 SOLAS (20) II-2/14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 October 2021 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The upper trailer deck sprinkler system is missing sprinkler heads and end caps rendering the system inoperative. Restore system and operationally test prior to carrying cargo in the upper trailer deck. 74 SOLAS (20) II-2/14.2.1.2
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 5 October 2021 Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed to sea without danger to the ship or persons aboard. Two ventilation covers for the cargo ventilation fan plenum on the forward side of the house – foc'sle, had wasted and brittle gaskets. 74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2021
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 5 October 2021 Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed to sea without danger to the ship or persons aboard. Crop and renew wasted deck iwo lifeboat No. 2. 74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 October 2021
Resolution: Resolved by Class report 4937495 dated 24 Sep 2021.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 5 October 2021 Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed to sea without danger to the ship or persons aboard. Descale and gauge wasted deck between upper trailer deck and fish freezer. 74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 5 October 2021 Resolved
Posters or signs shall be provided on or in the vicinity of survival craft illustrating the procedures for operating the appliance. The starboard liferaft embarkation did not have operating procedures posted. 74 SOLAS (20) III/8.2.1
Action required: 10 - Deficiency Rectified
Resolved 5 October 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 25 August 2021 Resolved
Each lifeboat shall be launched and maneuvered in the water at least once every three months. Launch and maneuver port lifeboat to satisfaction of CGMI prior to passing seaward of seabuoy, as soon as possible. 74SOLAS(20)III/19.3.4.3
Action required: 705 - Other - as specified
Resolved 1 October 2021
Resolution: Provided video of lifeboat launching and maneuvering.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 October 2020 Resolved
There must be an alternative means for providing water for fire fighting. The emergency fire pump's priming pump would not disengage and started smoking.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 October 2020
Resolved 16 October 2020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 October 2020 Resolved
A cargo ship shall be provided with fire pumps complying with regulation 56 of this chapter. The main fire pump discharge elbow has a pinhole leak.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 October 2020
Resolved 16 October 2020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 October 2020 Resolved
A cargo ship shall be provided with fire pumps complying with regulation 56 of this chapter. The fire/general service pump discharge elbow has a pinhole leak.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 October 2020
Resolved 16 October 2020
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 October 2020 Resolved
Holes were discovered drilled through the bulkhead of Laundry room & passageway on the 03 deck penetrating the Class B Boundary.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 16 October 2020
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 October 2020 Resolved
Holes were discovered drilled through the bulkhead of 01-07 Store room & passageway in a Class B Boundary.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 16 October 2020
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 October 2020 Resolved
Access Plate was unsecured and had approx 3" drilled hole in the bulkhead of the reefer machinery space & the passageway on the 01 Deck in a Class B Boundary.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 16 October 2020
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 October 2020 Resolved
MCTs in 03-33 Locker, 01-17 Electrical Closet overhead & and 01-32 store room were made up & patched with different materials.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 16 October 2020
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 13 October 2020 Resolved
Ventilation Dampers 3,4,5,18,19 & 20 for Cargo spaces would not close.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2020
Resolved 16 October 2020
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 13 October 2020 Resolved
Containment around NO.3 Fuel Oil Tank Vent Port side had a hole from wastage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 16 October 2020
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 13 October 2020 Resolved
Wastage hole was discovered in bottom of bulkhead of fan room and upper trailer deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 16 October 2020
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 13 October 2020 Resolved
Ice had accumulated in significant quantities on the deck and on the shelves in the deep freeze refer posing a safety hazard of slips, trips & falls.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 16 October 2020
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 October 2020 Resolved
Upon activation vessel shall conduct Fire & Abandon ship drill to the satisfaction of attending U.S.C.G. Marine Inspector.
Action required: 705 - Other - as specified
Due 13 October 2020
Resolved 25 August 2021
Resolution: Witnessed satisfactory fire and abandon ship drills.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 13 October 2020 Resolved
Upon activation vessel is to provide MMCs for all crew members required IAW the COI.
Action required: 705 - Other - as specified
Due 13 October 2020
Resolved 25 August 2021
Resolution: Verified valid MMCs and TWICs.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 October 2020 Resolved
Upon activation vessel must provide updated charts and publications.
Action required: 705 - Other - as specified
Due 13 October 2020
Resolved 25 August 2021
Resolution: Verified current navigation charts and publications.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 13 October 2020 Resolved
Vessel had majority of lifesaving equipment not stowed in proper locations because vessel is in ROS status. Upon activation all lifesaving equipment should be placed in proper location and verified by attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 13 October 2020
Resolved 25 August 2021
Resolution: Verified proper stowage of all lifesaving equipment.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 October 2020 Resolved
Heat detector was missing in bow thruster room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 16 October 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2020 Resolved
Steering would only go to 30 degrees STBD in Follow-Up mode.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 16 October 2020
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 23 August 2018 Resolved
Upon activation, vessel must conduct abandon ship/fire/security drills (if applicable) to the satisfaction of the attending MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 September 2018
Resolution: Vessel conducted fire and abandon ship drill to the satisfaction of the attending CG Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 August 2018 Resolved
Vessel does not keep up to date publications due to ROS status. Vessel must provide publications to USCG Marine Inspector prior to activation.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 September 2018
Resolution: Vessel has onboard updated nautical charts and electronic publications.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 23 August 2018 Resolved
Upon activation, vessel is to provide MMCs for all crew members when vessel is fully crewed, iaw COI manning, to a USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 September 2018
Resolution: Vessel provided MMCs for all crewmembers manning the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 August 2018 Resolved
Engine room fire damper became hung up preventing complete closure upon activation due to wire rope coming off of sheave. (SOLAS 60 Ch II Reg 27)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2018
Resolved 4 September 2018
Resolution: Received ABS email documentation verifying that repairs had been made.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 August 2018 Resolved
A wire run on the STBD side engine room has unauthorized hangers and splices. This is a power supply for the "MARAD ALARM" and it runs from the pressure vessel near the fwd/stbd air receiver to near the shaft seal. (SOLAS 60 Ch II Reg 27)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2018
Resolved 4 September 2018
Resolution: Received ABS email documentation verifying that repairs had been made
Operations/Management › Drills/Instruction › Abandon Ship
Issued 2 October 2017 Resolved
Upon activation, vessel must conduct abandon ship/fire/security drill (if applicable) to the satisfaction of attending MI.
Action required: 705 - Other - as specified
Resolved 23 August 2018
Resolution: resolved deficiency administratively and reissued to coincide with 2018 ACP Annual Inspection.
Navigation › Piloting/Steering › Marine Charts
Issued 2 October 2017 Resolved
Vessel does not keep up to date charts and publications due to ROS status. Vessel must provide charts and publications to USCG Marine Inspector prior to activation.
Action required: 705 - Other - as specified
Resolved 23 August 2018
Resolution: resolved deficiency administratively and reissued to coincide with 2018 ACP Annual Inspection.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 2 October 2017 Resolved
upon activation, vessel is to provide MMCs for all crew members when vessel is fully crewed IAW COI Manning to a USCG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 23 August 2018
Resolution: resolved deficiency administratively and reissued to coincide with 2018 ACP Annual Inspection.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 2 October 2017 Resolved
The Fire Detection System (System #3) is showing a trouble alarm for the ECR Changing Room. Verify proper operation to the satisfaction of class.
Action required: 705 - Other - as specified
Resolved 10 October 2017
Resolution: Documentation provided to USCG MIs that item was satisfactorily cleared by class surveyor.
Fire Fighting › Fire Main › Condition
Issued 27 October 2016 Resolved
MI found small hole in vessel's fire main, in machinery space in way of ship's service boiler. Repair fire main to the satisfaction of attending ABS surveyor prior getting underway.
Action required: 705 - Other - as specified
Resolved 8 December 2016
Resolution: 08 DEC 16 - Received ABS surveyor report dated 07 Dec 16 class report for the repair of a hole in the fire main IWO Aux boiler, Cleared associated CG-835 IAW ACP procedures.
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 October 2015 Resolved
Vessel crewed for Reduced Operating Status (ROS). Demonstrate fire and abandon ship drills prior to underway at activation to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 May 2017
Resolution: Crew demonstrated satisfactory fire and abandon ship drills prior to activation.
Personnel › Certificates/Documents/Licenses › License, Assistant Engineer
Issued 19 October 2015 Resolved
Provide crew documents, up to date charts, and nautical publications prior to underway at activation to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 May 2017
Resolution: Conducted inspection of all merchant mariner credentials for entire crew prior to activation.
Operations/Management › Drills/Instruction › Fire
Issued 15 September 2010 Resolved
Fire and abandonship drills shall be completed prior to the vessel operating.
Action required: 705 - Other - as specified
Due 15 September 2010
Resolved 12 October 2011
Resolution: Vessel continues to be in ROS. Reissued CG-835 this date.
Personnel › Certificates/Documents/Licenses › License, Assistant Engineer
Issued 15 September 2010 Resolved
Licenses with proper STCW endorsements, along with MMD's and TWIC's shall be verified prior to the vessel operating.
Action required: 705 - Other - as specified
Due 15 September 2010
Resolved 12 October 2011
Resolution: Vessel continues to be in ROS. Reissued CG-835 this date.
Engineering › Bilge Water Management System › Not Operational
Issued 25 August 2008 Resolved
Secondary bilge high level alarm was remove from the system, reinstall unit troubleshoot, repair and demonstrate satisfactory operation of the bilge high level alarm system. Also amend automation test as required.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2008
Resolved 25 August 2008
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 28 July 2008 Resolved
Repair or renew leaking sludge tank discharge valve near the OWS
Condition: Improper/Lack of Maintenance
Due 28 August 2008
Resolved 25 August 2008
Resolution: Valve repacked, all sat.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 July 2008 Resolved
Demonstrate proper operation of the OWS, also verify the OWS piping IAW the approved drawing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2008
Resolution: Proper operation of OWS observed, all piping and valves are as approved drawings.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 28 July 2008 Resolved
Properly install the hoses on the CO2 bottles. Hoses are kinked.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2008
Resolution: New hoses installed, all sat.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 28 July 2008 Resolved
Repair or replace the F/O valve on the main line in the engine room IWO the CPP controllers
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2008
Resolution: Valve repaired, all sat.
Electrical › Electric Generation Source (service) › Generator
Issued 28 July 2008 Resolved
Demonstrate proper operation of SS generators
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2008
Electrical › Lighting (service) › Outlet Box
Issued 28 July 2008 Resolved
Properly install overhead light J-box by the ladder between the CO2 lockers.
Condition: Improper/Lack of Maintenance
Due 28 August 2008
Resolved 25 August 2008
Resolution: Box cover properly installed.
Engineering › Bilge Water Management System › Interface Detector
Issued 25 July 2008 Resolved
Repair bilge sensor and properly mount stand pipe for the same.
Due 25 August 2008
Resolved 9 September 2008
Resolution: DF re-issued.
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 October 2007 Resolved
Upon activation complete Boat/fire drills as well as prove minimum safe manning.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 30 March 2009
Resolution: Conducted drills, and proved safe manning.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 August 2006 Resolved
Repair/Replace all faulty Lifebouy lights prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2006
Resolution: Cleared by ABS surveyor.
Fire Fighting › Fire Hydrants › Condition
Issued 11 August 2006 Resolved
Repair/Renew all leaking fire main valves.
Action required: 705 - Other - as specified
Due 18 August 2006
Resolved 21 August 2006
Resolution: Cleared by ABS surveyor.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 11 August 2006 Resolved
Make permanent repairs to the portside aft windlass control station.
Action required: 705 - Other - as specified
Due 11 September 2006
Resolved 21 September 2006
Resolution: Permanent repairs to portside aft windlass control station completed.
Engineering › Steering Gear System › Power Unit
Issued 11 August 2006 Resolved
Prove proper operation of the steering gear low oil level alarms and loss of power alarms.
Action required: 705 - Other - as specified
Resolved 21 August 2006
Resolution: Cleared by ABS surveyor.
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 January 2003 Resolved
Make permanent repairs to hole in sea water cooling manifold.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2003
Deck/Cargo › Holds/Tanks
Issued 30 January 2003 Resolved
Reseal and replace missing bolts to leaking fuel tank manhole covers on tank top cargo deck. Remove fuel residue from tank top cargo deck. LEGACY COMPONENT DESC: Hatch Cover
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2003
Electrical › Lighting (service)
Issued 30 January 2003 Resolved
Replace all missing globe guards for naked light fixtures on tank top and lower trailer deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 30 January 2003 Resolved
Service or replace fire extinguishers on spar deck.
Action required: 705 - Other - as specified
Due 1 March 2003
Resolved 30 January 2003
Navigation › Piloting/Steering
Issued 29 July 2002 Resolved
Provide correct tide and tidal current tables to the satisfaction of ABS or USCG Marine Inspector. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 705 - Other - as specified
Due 29 August 2002
Resolved 16 September 2002
Operations/Management › Drills/Instruction
Issued 29 July 2002 Resolved
Conduct drills to the satisfaction of an attending USCG Marine Inspector prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 July 2003
Resolved 16 September 2002
Resolution: Conducted Fire and Boat drills.
Lifesaving
Issued 14 June 2001 Resolved
CLEAN EXCESSIVE FUEL/OIL AND TRASH FROM ALL ENGINE ROOM BILGES TO THE SATISFACTION OF ABS SURVEYOR OR CG INSPECTOR
Condition: Unknown
Due 27 July 2001
Resolved 29 July 2002
Resolution: Cleared by ABS during survey.
Fire Fighting
Issued 14 June 2001 Resolved
REPAIR FIRE MAIN VALVES THROUGH OUT THE SHIP VESSEL TO SATISFACTION OF ABS SURVEYOR OR CG INSPECTOR. VALVES ARE LEAKING BY AND PRESSURIZING FIRE HOSES.
Condition: Unknown
Due 27 July 2001
Resolved 29 July 2002
Resolution: Cleared by ABS during survey. This item was spot checked by USCG inspectors during annual exam.
Engineering
Issued 14 June 2001 Resolved
REMOVE ALL BYPASS LINES ON OWS DISCHARGE PIPING PRIOR TO OPERATING THE OWS AND TO THE SATISFACTION OF CG INSPECTOR.
Condition: Unknown
Due 27 July 2001
Resolved 29 July 2002
Resolution: Cleared by ABS during survey.
Lifesaving
Issued 14 June 2001 Resolved
CONDUCT FIRE AND BOAT DRILL PRIOR TO ACTIVATION AND TO THE SATISFACTION OF CG INSPECTOR.
Condition: Unknown
Due 14 July 2002
Resolved 29 July 2002
Resolution: Cleared this requirement and reissued CG-835 for new inspection year.
Navigation
Issued 14 June 2001 Resolved
PROVE PROPER OPERATION OF DEPTH FINDER TO SATISFACTION OF CG INSPECTOR OR ABS SURVEYOR.
Condition: Unknown
Due 27 July 2001
Resolved 29 July 2002
Resolution: Cleared by ABS during survey.
Documentation
Issued 14 June 2001 Resolved
IMPLEMENT GARBAGE MANAGEMENT PLAN INCLUDING ESTABLISHING A GARBAGE RECORD LOG TO SATISFACTION OF ABS SURVEYOR OR CG INSPECTOR.
Condition: Unknown
Due 27 July 2001
Resolved 29 July 2002
Resolution: Cleared by ABS during survey.
Lifesaving
Issued 14 June 2001 Resolved
PROVIDE NEW EMBARKATION LADDERS OF THE PROPER LENGTH.
Condition: Unknown
Due 27 July 2001
Resolved 29 July 2002
Resolution: Cleared by ABS during survey.
Documentation
Issued 14 June 2001 Resolved
PROVIDE ORIGINAL STCW FOR 2ND A/E TIM DOOLEY PRIOR TO GETTING UNDERWAY TO CG INSPECTOR
Condition: Unknown
Due 27 July 2001
Resolved 29 July 2002
Resolution: Cleared by ABS during survey.
Documentation
Issued 14 June 2001 Resolved
PROVIDE VALID STCW FOR 3RD A/E JOHN BEAMON PRIOR TO GETTING UNDERWAY TO CG INSPECTOR.
Condition: Unknown
Due 27 July 2001
Resolved 29 July 2002
Resolution: Cleared by ABS during survey.
Engineering
Issued 14 June 2001 Resolved
INSTALL COVERS OVER EXPOSED PULL AND BELTS ON EMERGENCY GEN TO SATISFACTIONOF ABS SURVEYOR OR CG INSPECTOR
Condition: Unknown
Due 27 July 2001
Resolved 29 July 2002
Resolution: Cleared by ABS during survey.
Electrical
Issued 14 June 2001 Resolved
ELIMINATE GROUND ON EMER GEN SWITCHBOARD TO SATISFACTION OF ABS URVEYOR OR CG INSPECTOR
Condition: Unknown
Due 27 July 2001
Resolved 29 July 2002
Resolution: Cleared by ABS during survey.
Fire Fighting
Issued 7 March 2000 Resolved
SUBMIT DRAWING OF SMOKE/FIRE DETECTION SYSTEM REVISION OF ZONES 4-14 TO MARINE SAFETY CENTER FOR APPROVAL.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Documentation
Issued 22 October 1999 Resolved
PROVIDE APPROVED/REVISED FIRE CONTROL PLAN REFLECTING IMO SYMBOLOGY FROM ADDITION OF SPARDECK.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Construction/Loadline
Issued 31 July 1999 Resolved
Vent line in #4 wing ballast tank cracked at deck weld iwo main trailer deck.
Condition: Unknown
Due 6 January 2000
Resolved 6 January 2000
Lifesaving
Issued 31 July 1999 Resolved
Lifeboat foredeck has cracked seam on port side.
Condition: Unknown
Due 6 January 2000
Resolved 6 January 2000
Engineering
Issued 31 July 1999 Resolved
Auxiliary Boiler and waste steam generator mounts past due for opening and inspection. ABS Survey of mounts due 1/31/00. Make mounts available for or provide satisfactory ABS report to local USCG Marine Inspector.
Condition: Unknown
Due 31 July 1999
Resolved 31 July 1999
Construction/Loadline
Issued 31 July 1999 Resolved
Vent line for #3 port wing ballast tank cracked iwo main trailer deck.
Condition: Unknown
Due 7 December 1999
Resolved 7 December 1999
Lifesaving
Issued 31 July 1999 Resolved
Outer stern tube housing cracked on motorized lifeboat.
Condition: Unknown
Due 6 January 2000
Resolved 6 January 2000
Construction/Loadline
Issued 31 July 1999 Resolved
Vent line for #3 stbd wing ballast tank cracked at coulpling iwo main trailer deck.
Condition: Unknown
Due 6 January 2000
Resolved 6 January 2000
Construction/Loadline
Issued 31 July 1999 Resolved
Vent line for #3 stbd wing ballast tank holed and has soft patch iwo main trailer deck.
Condition: Unknown
Due 6 January 2000
Resolved 6 January 2000
Engineering
Issued 4 August 1998 Resolved
PROVE PROPER OPERATION OF THE LOW LOW WATER ALARM ON THE AUXILIARY BOILER.
Condition: Unknown
Due 18 August 1998
Resolved 25 August 1998
Engineering
Issued 4 August 1998 Resolved
PROVE PROPER OPERATION OF AUXILIARY BOILERS SAFETY RELIEF VALVES.
Condition: Unknown
Due 18 August 1998
Resolved 25 August 1998
Engineering
Issued 4 August 1998 Resolved
PROVE PROPER OPERATION OF MAIN PROPULSION AUTOMATION TEST PROCEDURES.
Condition: Unknown
Due 18 August 1998
Resolved 25 August 1998
Navigation
Issued 4 August 1998 Resolved
UPDATE DEVIATION TABLE FOR MAGNETIC COMPASS.
Condition: Unknown
Due 18 August 1998
Resolved 25 August 1998
Lifesaving
Issued 6 January 1998 Resolved
PRIOR TO DEPARTING THE PORT OF HAMPTON ROADS, PROVIDE NEW MEDICATIONS IN HOSPITAL SPACE.
Condition: Unknown
Due 6 January 1998
Resolved 6 January 1998
Electrical
Issued 22 September 1997 Resolved
PROVIDE REPAIR PROPOSAL FOR VENTILATION INSTALLTION IN WAY OF BATTERY ROOM
Condition: Unknown
Due 22 September 1997
Resolved 22 September 1997
Fire Fighting
Issued 9 September 1997 Resolved
PROVE PROPER OPERATION OF ENGINE ROOM VENTILATION FAN SHUTDOWNS FOR CO2 RELEASE.
Condition: Unknown
Due 9 September 1997
Resolved 9 September 1997
Electrical
Issued 9 September 1997 Resolved
REPLACE OR REPAIR VARIOUS LIGHT FIXTURES THROUGHOUT THE VESSEL
Condition: Unknown
Due 9 September 1997
Resolved 9 September 1997
Lifesaving
Issued 9 September 1997 Resolved
PRIOR TO DEPARTING THE PORT OF HAMPTON ROADS, PROVIDE NEW MEDICATIONS IN HOSPITAL SPACE.
Condition: Unknown
Due 9 September 1997
Resolved 9 September 1997
Fire Fighting
Issued 9 September 1997 Resolved
PROVIDE MISSING INSTRUCTION PLACARDS FOR CLOSING ENGINE ROOM VENTILATION DAMPERS PRIOR TO CO2 RELEASE AT REMOTE STATION.
Condition: Unknown
Due 9 September 1997
Resolved 9 September 1997
Electrical
Issued 29 August 1996 Resolved
MAKE PERMANENT REPAIRS I.W.O. EMERGENCY LIGHT BRACKET AFT OF STBD BOAT DECK.
Condition: Unknown
Due 20 September 1996
Resolved 20 September 1996
Lifesaving
Issued 29 August 1996 Resolved
REPAIR WASTED GUIDE ON SHIVE I.W.O. PORT LIFEBOAT FALLS.
Condition: Unknown
Due 20 September 1996
Resolved 20 September 1996
Lifesaving
Issued 29 August 1996 Resolved
MAKE PERMANENT REPAIRS I.W.O. WASTED BIT ON STBD LIFEBOAT DAVIT.
Condition: Unknown
Due 20 September 1996
Resolved 20 September 1996
Fire Fighting
Issued 29 August 1996 Resolved
PRIOR TO DEPARTURE FROM THE PORT OF HAMPTON ROADS, PERFORM REQUIRED ANNUAL SERVICING OF FIRE DETECTION AND EXTINGUISHING EQUIPMENT TO COAST GUARD SATISFACTION.
Condition: Unknown
Due 10 October 1996
Resolved 27 September 1996
Navigation
Issued 29 August 1996 Resolved
MAKE PERMANENT REPAIRS I.W.O. RUDDER ANGLE INDICATOR (PORT SIDE), CORRECT FIVE DEGREE DEVIATION.
Condition: Unknown
Due 20 September 1996
Resolved 20 September 1996
Electrical
Issued 29 August 1996 Resolved
PRIOR TO DAPARTURE FROM THE PORT OF HAMPTON ROADS, INSTALL PROPER ELECTRICAL CONNECTIONS I.W.O. EMERGENCY LIGHTS AND POWER TO THE DECK HOUSE IAW 46CFR112.20-15.
Condition: Unknown
Due 20 September 1996
Resolved 20 September 1996
Electrical
Issued 21 November 1995 Resolved
PROVIDE ENOUGH EMERGENCY LIGHTING IN THE ENGINE ROOM AND THE ENGINE CONTROLROOM TO MEET THE REQUIREMENTS IN 46CFR112.15-1(b).
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995
Accommodation/Occupational Safety
Issued 10 November 1994 Resolved
REPAIR OR REPLACE MISSING BUNKLIGHT ABOVE OUTBOARD BUNK IN WIPER STATEROOM.
Condition: Unknown
Due 10 December 1994
Resolved 6 January 1995
Documentation
Issued 10 November 1994 Resolved
UPON RECEIPT, PROVIDE THE FOLLOWING CLASSIFICATION SOCIETY CERTIFICATES FORREVIEW: SAFETY CONSTRUCTION, LOADLINE, AND CERTIFICATES OF CLASS.
Condition: Unknown
Due 10 December 1994
Resolved 6 January 1995
Engineering
Issued 10 November 1994 Resolved
DURING SEA TRIALS, TEST THE WASTE HEAT BOILER SAFETY VALVE. THE LIFT AND RESEAT PRESSURES ARE TO BE LOGGED IN THE VESSEL'S MACHINERY LOG.
Condition: Unknown
Due 10 December 1994
Resolved 6 January 1995
Navigation
Issued 3 April 1990 Resolved
A VIO OF 33 CFR 164.11(R) IN THAT THE RADAR REQ BY 33 CFR 164.35(A) WAS NOT MAINTAINED IN AN OPERABLE CONDITION WHILE THE VSL WAS U/W IN THE NAVIGABLE WATERS OF THE U.S.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Navigation
Issued 19 August 1987 Resolved
33CFR164.33(A)(1)(II) CHARTS OF THE AREA WERE NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 19 August 1987
Resolved 19 August 1987
Navigation
Issued 19 August 1987 Resolved
33CFR164.11(A) TEST REQUIRED BY 33CFR164.25 WERE NOT RECORDED IN VESSEL'S LOG.
Condition: Unknown
Due 19 August 1987
Resolved 19 August 1987
Navigation
Issued 19 August 1987 Resolved
33CFR164.33(A)(2)(I) COAST PILOT VOLUME V WAS NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 19 August 1987
Resolved 19 August 1987
Documentation
Issued 19 August 1987 Resolved
33CFR155.820(D) VESSEL DID NOT HAVE SIGNED COPY OF THE DECLARATION OF IN- SPECTION.
Condition: Unknown
Due 19 August 1987
Resolved 19 August 1987
Navigation
Issued 28 January 1985 Resolved
A VIOLATION OF 33 CFR 164.11(Q) IN THAT THE PRE-ARRIVAL TESTS REQUIRED BY 33 CFR 164.25 WERE NOT LOGGED.
Condition: Unknown
Due 28 January 1985
Resolved 28 January 1985
Navigation
Issued 28 January 1985 Resolved
STEERING GEAR OPERATING AND CHANGEOVER INSTRUCTIONS AND DIAGRAM REQUIRED BY33 CFR 164.35(K) WERE NOT PERMANENTLY DISPLAYED ON THE BRIDGE.
Condition: Unknown
Due 28 January 1985
Resolved 28 January 1985

Casualty record · 10

1 April 2009Routine · role: Involved in a Marine Casualty · activity 3444352
11 September 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4734829
15 August 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4965827
18 June 2019Routine · role: Involved in a Marine Casualty · activity 6719559
25 June 2023Routine · role: Involved in a Marine Casualty · activity 7726980
2 July 2023Routine · role: Involved in a Marine Casualty · activity 7744320
2 July 2023Routine · role: Involved in a Marine Casualty · activity 7820619
6 October 2023Routine · role: Involved in a Marine Casualty · activity 7807012
27 October 2023Routine · role: Involved in a Marine Casualty · activity 7816746
12 November 2023Routine · role: Involved in a Marine Casualty · activity 7830255
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.