MAURY USCG vessel records
← All vessels

CAPE RAY

CAPE RAY is a 1977 freight ship. The Coast Guard has recorded 26 inspections since 2016, most recently in April 2025, along with 42 deficiencies and 3 casualty investigations in 2018.

Records from 2016 to 2025. Most recent: inspection, 11 April 2025.

Built
1977
Last inspected
11 April 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 April 2025
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7530810
224579
Flag
SAUDI ARABIA
Maury page id
psix-224579

Documentation record

Registered dimensions (L × B × D)594.6 ft × 105.6 ft × 65.1 ft
Registered tonnagegross 31,236 / net 9,370
ITC dimensions (L × B × D)594.6 ft × 105.6 ft × 65.1 ft
ITC tonnagegross 31,236 / net 9,370
BuilderKAWASAKI HEAVY INDUSTRIES · SAKAIDE, JAPAN · built 1977
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Trade endorsementsRegistry
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31236 - Convention (Subpart B), Gross Ton
9370 - Convention (Subpart B), Net Ton
22735 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LULU Tank Ship · MISLE 652867 · 27 September 2022 · activity 7714136

Inspection history · 26

11 April 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8110110
24 June 2024 Deficiency Check · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7939212
9 May 2023 Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7683596
27 September 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7714136
21 July 2022 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7515776
20 July 2022 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7512187
29 June 2022 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7490325
23 June 2021 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7232474
3 November 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7088974
22 June 2020 Re-Inspection · MTSA/ISPS Verification · ACP Additional Oversight – Risk Assessment · ACP Drydock Oversight · Administrative Inspection · ACP COI Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6992586
28 May 2020 Exemption
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6962387
20 September 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6816520
26 June 2019 ACP Annual Oversight · Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6727141
17 October 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6562806
17 September 2018 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6542491
15 August 2018 In-Service Inspection
Physical examination · Activities Europe · Activity 6518586
29 July 2018 Type not recorded
No type recorded · Activities Europe · Activity 6510208
26 June 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6456362
7 June 2018 Type not recorded
No type recorded · Activities Europe · Activity 6444970
4 June 2018 Type not recorded
No type recorded · Activities Europe · Activity 6434625
4 June 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6448522
17 May 2018 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6420279
9 May 2018 Deficiency Check · Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6408779
8 May 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6409125
25 May 2017 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6153276
30 September 2016 ACP Annual Oversight
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6006461

Deficiency record · 42

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 24 June 2024 Resolved
Each emergency generator set arranged to be automatically started shall be equipped with starting devices approved by the Administration with a stored energy capability of at least three consecutive starts. A second source of energy shall be provided for an additional three starts within 30 min unless manual starting can be demonstrated to be effective. Vessel was unable to demonstrate the required amount of starts. 74 SOLAS (97) II-1/44.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2024
Resolved 3 July 2024
Resolution: MIs witnessed testing in person, all sat.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 24 June 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. General Emergency alarm in steering gear room found inoperable. 74 SOLAS (20) III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2024
Resolved 28 June 2024
Resolution: Accepted by RO
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 24 June 2024 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: protection of openings and penetrations in these divisions. Found engine room #3 supply fan closure missing a section of gasket material, causing a gap in the closure. 74 SOLAS (20) II-2/14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2024
Resolved 28 June 2024
Resolution: Accepted by RO
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 24 June 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The visual indicator for loss of power alarm of both steering gear pumps on the bridge is inoperable. 74SOLAS(20) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2024
Resolved 28 June 2024
Resolution: Accepted by RO
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 June 2024 Resolved
Life-saving appliances and arrangements shall be approved by the Administration. The following approval series indicate approval to the SOLAS requirements: 160.122 Floating orange smoke signals Smoke for the bridge wing life buoy on the STBD side does not meet 160.122. 74 SOLAS(20) III/4.1 US Supplement to ABS Rules for Steel Vessels for Vessels on International Voyages 74SOLAS(20) III/4.1 US Supplement to ABS Rules for Steel Vessels for Vessels on International Voyages
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2024
Resolved 28 June 2024
Resolution: Accepted by RO
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 24 June 2024 Resolved
Each item of radio communications equipment must be type accepted by the Federal Communications Commission. Two-way VHF radiotelephone apparatuses must conform to performance standards as specified in § 80.1101.The equipment specified in this subpart must also conform to the appropriate performance standards listed: (7) Two-Way VHF radiotelephone: (i) IMO Resolution A.809(19), as revised by IMO Resolution MSC.149(77). Vessel’s required three sealed primary batteries for the three two-way VHF radios are not FCC approved. US Supplement to ABS Rules for Steel Vessels for Vessels on International Voyages 47 CFR 80.1095(a) 47 CFR 80.1101(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2024
Resolved 28 June 2024
Resolution: Accepted by RO
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 June 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. 03 dampers on the STBD side would not close. 74SOLAS(20) I/11
Action required: 10 - Deficiency Rectified
Resolved 24 June 2024
Resolution: Adjusted dampers to close properly.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 June 2024 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection. Found two smoke detectors in the steering gear room, and one in the lower-level engine room port side were not installed. 74 SOLAS (20) II-2/14.2.1.1.2 74 SOLAS (20) II-2/14.2.1.1.2
Action required: 10 - Deficiency Rectified
Resolved 24 June 2024
Resolution: Installed missing smoke detectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 July 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported 01 of 02 hydraulic pumps for the controllable-pitch propeller inoperable due to a failed seal. 74 SOLAS(20)I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2022
Resolved 12 August 2022
Resolution: Accepted by class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 July 2022 Resolved
Each District Commander or Captain of the Port may order a vessel to operate or anchor in the manner directed when: it has determined that such order is justified in the interest of safety by reason of weather, visibility, sea conditions, temporary port congestion, other temporary hazardous circumstances, or the condition of the vessel. Vessel is required 01 tug of 3,000 HP or 02 tugs of 2,000 HP escort tugs for transit to berth. 33 CFR 160.111(c)
Action required: 705 - Other - as specified
Due 4 August 2022
Resolved 25 July 2022
Resolution: Vessel acquired tugs to transit to berth.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 July 2022 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The launching mechanism shall be so arranged that it may be actuated by one person from a position of the ships deck and from a position within the survival craft. Remote cable for #1 lifeboat did not operate as originally designed when used through the cable port hole on top of the lifeboat. 20 SOLAS III/20.2 & LSA Code 6.1.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2022
Resolved 11 August 2022
Resolution: The remote cable was adjusted and proper operation was demonstrated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 29 June 2022 Resolved
A food ration, determined by the Administration, for each person the lifeboat is certificated to carry. These rations shall be kept in airtight receptacles. STBD lifeboat did not have required amount of food rations after 8 packages were found with loss of vacuum, vessel is restricted to carrying 39 Crew. Reg III/20 SOLAS (2020 edition)
Action required: 705 - Other - as specified
Resolved 14 July 2022
Resolution: Accepted as a condition of ACS.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 June 2022 Resolved
All the lifesaving appliances shall be kept in working order and be available for immediate use before the ship leaves port and at all times during the voyage. Vessel's STBD lifeboat navigational light was inoperable. Repair or test to the satisfaction of classification society. Reg III/20 SOLAS (2020 edition)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 July 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 June 2022 Resolved
Fire extinguishing appliances in new and existing cargo ships shall be kept in good working order and available for immediate use at all times during a voyage. Multiple fixed CO2 hoses with sharp bends were found to have the outer rubber layer dry-rotted exposing the inner layers of the hoses in both Port & STBD CO2 rooms. Replace or test to the satisfaction of classification society. Reg II-2/14 SOLAS (2020 edition)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 July 2022
Resolution: Accepted as a condition of ACS.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 June 2022 Resolved
Means of illuminating the lifeboats and their launching gears during preparation for and the process of launching, and also for illuminating the water into which the lifeboats are launches until the process of launching is completed. Vessels STBD aft liferaft, STBD lifeboat, and fwd liferaft embarkation lights were inop. Replace or test to the satisfaction of classification society. Reg III/20 SOLAS (2020 edition)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2022
Resolution: Accepted as a condition of ACS.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 29 June 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Audible & Visual steering alarms were not operating on the bridge. Corrected on the spot. 74 SOLAS (20) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 29 June 2022
Resolution: MI's witnessed sat operational test of steering gear alarms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found sewage tank lower level port side engine room leaking at the chlorinator. 74 SOLAS (20) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 July 2022
Resolution: Accepted as a condition of ACS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found engine room ventilation supply fans #1 and #4 not operational. 74 SOLAS (20) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 July 2022
Resolution: Accepted as a condition of ACS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 June 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found ships service & control air compressors and associated piping removed from service. New piping is currently being fabricated and installed. New compressors are on order. 74 SOLAS (20) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 July 2022
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 June 2021 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations shall be kept in good order so as to ensure their required performance if a fire occurs. Multiple cable transits in bridge deck and electrical space 02-29 have been disturbed and need repaired to OEM specs. 74 SOLAS (20) II-2/14.2.1.1.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship is fit to proceed to sea without danger to ship or persons aboard. Several ring life buoys need retro-reflective tape renewed. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship is fit to proceed to sea without danger to ship or persons aboard. Ring life buoy iwo of No. 2 lifeboat had plug removed and filled with epoxy. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 June 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship is fit to proceed to sea without danger to ship or persons aboard. Exhaust on the emergency diesel generator was leaking. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2021
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 23 June 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship is fit to proceed to sea without danger to ship or persons aboard. Deck underneath the engine control room was wasted. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 July 2021
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 23 June 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure ship is fit to proceed to sea without danger to ship or persons aboard. Steel iwo fire station No. 46 and starboard CO2 compartment deck found wasted. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 July 2021
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 23 June 2021 Resolved
After any survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey. Found space heater in 02-27 pway, hard-wired into 440V installation in electrical distribution room. 74 SOLAS (20) I/11(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 23 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 June 2021 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations shall be kept in good order so as to ensure their required performance if a fire occurs. Found galley service door unable to close and latch.74 SOLAS (20) II-2/14.2.1.1.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 23 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Communication-SOLAS chap. 5
Issued 23 June 2021 Resolved
The Administration shall be satisfied that adequate arrangements are in place to ensure that the performance of the equipment required by this chapter is maintained. SARTs, EPIRB, lifeboat radios, and batteries were not stowed in proper locations. 74 SOLAS (20) V/16.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 23 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 June 2021 Resolved
Fire extinguishing appliances in new and existing passenger ships and cargo ships shall be kept in good order and available for immediate use at all times during the voyage. Found fire hose nozzles plugged with sediment upon testing fire pumps. 60 SOLAS II/66
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 June 2021 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Found expired lifebuoy self-activating smoke signal stowed with all in-use pyro. 74 SOLASD (20) III/20.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 23 June 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 June 2019 Resolved
Fire-fighting systems shall be kept in good working order and readily available for immediate use. One pilot bottle of first bank stbd side CO2 room was not connected. Found 5 flex loop hoses in disrepair and need to be replaced. SOLAS 74(14) II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 July 2019
Resolution: Inspected high pressure CO2 system and found system to be connected correctly and 5 flex loops were replaced due to deterioration; system sat
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 June 2019 Resolved
The fire detection and fire alarm systems shall be kept in good order so as to ensure their required performance if a fire occurs. The cargo deck fire detection system has a trouble alarm that will not clear. SOLAS 74(14) II-2/14.2.1.1.2
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2019
Resolution: Inspected fire detection panel for cargo holds and system was no longer in trouble status. Spoke with C/E and he explained that the sensors get dirty overtime and have to be cleaned periodically which was causing the trouble alarm; system sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 June 2019 Resolved
Means of illuminating the liferaft and their launching gear during preparation and for the process of launching, and also for illumination the water into which the liferaft are launched until the process of launching is completed. Aft port and stbd liferaft station embarkation lights were inop. SOLAS 60 III/19.b.iii
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2019
Resolved 1 July 2019
Resolution: Witnessed the testing of the embarkation lighting for the aft liferaft station; test sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 June 2019 Resolved
Posters or signs shall be provided on or in the vicinity of survival craft and their launching controls and shall be easily seen under emergency lighting conditions. Instructions for stbd lifeboat operations were not illuminated properly. SOLAS 74(14) III/9.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2019
Resolved 1 July 2019
Resolution: Witnessed emergency lighting for lifeboat station; test sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 June 2019 Resolved
Fire and abandonship drills not observed because of ROS status. Conduct drills in the presence of CG inpsector upon activation. All lifesaving equipment to be on station during drills. SOLAS 74(14) II-1/19.3
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2019
Resolution: Fire drill and abandonship drill observed, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 June 2019 Resolved
Charts and publications not examined because of ROS status. Provide up-to-date charts and publications to CG inspector upon activation. 33 CFR 164
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2019
Resolution: Updated paper charts and ECIS
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 26 June 2019 Resolved
Vessel's crew documents not examined because of ROS status. Provide MMCs, medical certification, and TWIC certificate for all crew upon manning for activation. 46 CFR 15.401
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2019
Resolution: Crew credentials,medical card and Twic inspected, all sat.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 August 2018 Resolved
The Company should establish procedures in SMS to identify equipment and technical systems that the sudden operational failure of which may result in hazardous situations. The SMS should provide for specific measures aimed at promoting the reliability of such equipment or system. These measures should include the regular testing of standy-by arrangements and equipment or technical systems that are not in continuous use and justify appropriate maintenance intervals. The main engine air cooler was identified by NS5 as a critical piece of equipment. After a malfunction of the port air cooler resulting in a reduction of propulsion marine casualty on the port main engine, it was discovered that the current maintenance procedures are based on hours of operation. The vessel is in ROS status for long periods and does not accumulate engine hours like a normal commercial vessel.The company shall conduct a root cause analysis to determine if the hours of operation preventative maintenance interval model is satisfactory for systems not in continuous use. The historical record shows the air cooler preventative maintenance was last completed on 28 July 2005 and is currently estimated to be examined on 18 November 2019 (14 year interval). The company shall provide the results of the root cause analysis to the Recognized Organization (ABS). THe Recognized Organization shall attest to the findings in the Root Cause Analysis provided by the company.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 15 October 2018
Resolution: Updated preventative maintenance to be scheduled not based on time-operated.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 August 2018 Resolved
The operation of the fire main system pumps, hydrants, piping, and nozzles shall be in good condition and available for immediate use. The discharge relief valve casing on the main fire pump was found wasted and leaking excessively. Crew temporarily isolated valve through use of a flange blank. Repair and verify integrity of the system to the satisfaction of a USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 15 October 2018
Resolution: Replaced discharge relief valve.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 30 September 2016 Resolved
Vessel is in ROS status and is minimally manned. Provide complete crew with credentials to the satisfaction of a Marine Inspector prior to activation.
Action required: 705 - Other - as specified
Resolved 16 May 2018
Resolution: Verified all MMC as per sailing list and COI.
Navigation › Piloting/Steering › Marine Charts
Issued 30 September 2016 Resolved
Vessel is in ROS status and does not have updated charts/publications. Provide updated charts and publications to the satisfaction of a Coast Guard Marine Inspector prior to activation.
Action required: 705 - Other - as specified
Resolved 16 May 2018
Resolution: Verified all required updated and corrected charts, NAV pubs and ECDIS updates.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 30 September 2016 Resolved
Vessel is in ROS status and minimally manned. Vessel shall conduct fire and abandon ship drill to the satisfaction of a Marine Inspector prior to activation.
Action required: 705 - Other - as specified
Resolved 16 May 2018
Resolution: Conducted successful fire and abandon ship drills.

Casualty record · 3

4 June 2018Routine · role: Involved in a Marine Casualty · activity 6434625
7 June 2018Routine · role: Involved in a Marine Casualty · activity 6444970
29 July 2018Routine · role: Involved in a Marine Casualty · activity 6510208
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.