MAURY USCG vessel records Sign in
← All vessels

SNOW CRYSTAL

SNOW CRYSTAL is a 1973 freight ship. The Coast Guard has recorded 21 inspections since 1985, most recently in March 2010, along with 18 deficiencies — 2 with no resolution recorded — and 6 operational controls.

Records from 1985 to 2010. Most recent: inspection, 17 March 2010.

Built
1973
Last inspected
17 March 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7321075 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ZKU2125
224593
Flag
COOK ISLANDS
—
Maury page id
psix-224593

Inspections, by type

…with no type recorded11
…past their stated due date2
Years with a record 8 calendar years (1985–2010)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it15710 - Dead Weight, Ton
8974 - Displacement, Ton
6736 - Convention (Subpart B), Net Ton
14512 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

17 March 2010 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3697192
9 April 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3449119
7 April 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3447766
10 March 2009 Deficiency Check · PI Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3431198
15 February 2009 PI Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3418070
15 February 2009 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3418224
11 February 2009 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3416453
17 October 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3562033
3 October 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3338222
2 October 2008 MARPOL Annex V Examination · Ballast Water Examination · PI Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3332525
2 April 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3176149
6 March 2008 ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3159273
7 February 2008 ISPS II Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3143163
7 January 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3125798
9 December 2003 Administrative Inspection · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1961007
30 September 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1913042
27 September 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 293971
11 February 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 400329
4 November 1994 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 371545
4 November 1994 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1161567
28 May 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 302235

Deficiency record · 18

Construction/Loadline › Structures › Door
Issued 17 March 2010 No resolution recorded
1270 - Load Line-Doors - PSCO found the door leading out of the crew recreational accommodation is not made of steel or equivalent material, permanently and strongly attached to the bulkhead and framed, stiffened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and weather tight. ICLL66 Annex I/12-20
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 April 2010 — due date passed with no resolution recorded
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 15 February 2009 Resolved
Emergency fire pump leaking from deck fittings during test. 2-3" of water was on deck following test. Pump was able to provide two effective streams of water, but leaks raised concerns as to how long fire pressure would be maintained in the event of long term use if the two main fire pumps were disabled.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2009
Resolution: Sector Delaware Bay attended vessel to clear deficiency. Two Class Surveyors were onboard and rectified deficiency prior to our arrival. A PSCO visually attested to the repair and confirmed Class'' rectification.
Engineering › Steering Gear System › Piping
Issued 15 February 2009 Resolved
Main steering gear functioned effectively during testing, however hydraulic oil leaks were observed while system was running. This raised concern that ability to steer could be jeopardized at some point.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2009
Resolution: Sector Delaware Bay attended vessel to clear deficiency. Two Class Surveyors were onboard and rectified deficiency prior to our arrival. A PSCO visually attested to the repair and confirmed Class'' rectification.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 15 February 2009 Resolved
Origional Safety Equipment Certificate not on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2009
Resolution: Class was attending the vessel while PSCO''s were onboard. Class issued an interim certificate while aboard.
Navigation › Piloting/Steering › Gyro Compass
Issued 15 February 2009 Resolved
Vessel's gyrocompass inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2009
Resolution: Tech report received. Gyro was repaired with a spare part that was already on board. Tech ordered a new part to replace the spare and delivered it to the vessel before issuing tech report. Gyro now working to specifications.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 15 February 2009 Resolved
Garbage management plan does not indicate person in charge of implementing the plan.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 March 2009
Resolution: Plan indicates PIC of implementing garbage management plan
Electrical › Lighting (service) › Lighting Fixture
Issued 15 February 2009 Resolved
Exterior lighting by aft fire locker damaged, supports are broken and fixture is hanging.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 February 2009
Resolution: Class was attending the vessel while PSCO''s were onboard. Lighting was repaired.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 2 October 2008 Resolved
Vessel to conduct a damage survey at the earliest opportunity after the cargo hold has been certified safe for workers by a marine chemist. The root cause of the fire, damage survey and repair proposal to include all structural, electrical and fire detection systems within the affected area must be approved and provided to the Coast Guard prior to loading or movement
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 27 October 2008
Resolution: Reviewed, received and accepted class report from [name withheld] stating all deficiencies are cleared.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 2 October 2008 Resolved
In order to suppress the fire, the ship used 36 bottles of CO2. Vessel is to replace all used CO2 bottles on board to the satisfaction of the certificate issuing authority prior to loading and movement.
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 27 October 2008
Resolution: Reviewed, received and accepted class report from [name withheld] stating all deficiencies were cleared.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 25 September 2008 Resolved
Thermostatic valves leaking jacket water on both the #2 and #3 Ship Service Diesel Generator.
Action required: 705 - Other - as specified
Resolved 16 October 2008
Resolution: Received class report from Lloyds Register satisfying requirement.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 25 September 2008 Resolved
Fuel oil viscometer pump in fuel oil purifier room has a piece of gasket material temporarily shielding a wire junction on the pump motor, in lieu of an actual junction box cover.
Action required: 705 - Other - as specified
Resolved 16 October 2008
Resolution: Received class report from Lloyd’s Register satisfying requirement.
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 25 September 2008 Resolved
Emergency generator fuel oil booster pump supply and discharge flexible hoses are dry rotted, causing leaks. Approximately one liter of diesel fuel was in catch basin underneath it.
Action required: 705 - Other - as specified
Resolved 16 October 2008
Resolution: Received class report from Lloyd''s Register satisfying requirement.
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 25 September 2008 Resolved
Vessel could not provide hydrostatic test record for bunkering manifold.
Action required: 703 - Prior to bunkering operations
Resolved 2 October 2008
Resolution: Vessel provided documentation to rectify discrepancy.
Navigation › Piloting/Steering › Gyro Compass
Issued 2 April 2008 Resolved
VESSEL MASTER INFORMAED SECTOR DELAWARE BAY THAT THE VSL'S GYROCOMPASS WAS INOPERATIVE.
Condition: Unknown
Due 2 April 2008
Resolved 4 April 2008
Resolution: Recieved tech report attesting to proper operation of the gyrocompass.
Electrical › Lighting (service)
Issued 30 September 2003 Resolved
Warming lights in vicinity of steering gear.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 December 2003
Resolution: RECEIVED CLASS REPORT.
Pollution Prevention/Response › Prevention Equipment
Issued 30 September 2003 Resolved
Concrete patch found around sewage overboard pipe stbd side, lower level, aft. LEGACY COMPONENT DESC: Sewage System Piping
Action required: 705 - Other - as specified
Resolved 9 December 2003
Resolution: RECEIVED CLASS REPORT.
Electrical
Issued 27 September 2001 No resolution recorded
Remove warming light bulbs from vicinity of emergency fire pump and steering gear pumps. Complete to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 11 October 2001 — due date passed with no resolution recorded
Resolution: REQUIREMENT WAS REISSUED AS CAPTAIN WAS UNAWARE OF DEFICIENCY.
Fire Fighting
Issued 27 September 2001 Resolved
Hole developed in firemain while under pressure. Renew wasted section of firemain, outboard of #5 S cargo hold, to the satisfaction of the attendingmarine inspector, COTP zone Mobile, AL. Requirement can be satisfied by receipt of a copy of class report attesting that repair was completed.
Condition: Unknown
Due 4 October 2001
Resolved 30 September 2003
Resolution: Ran fire pump and no holes were noted.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.