Records from 1985 to 1990. Most recent: inspection, 11 June 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
11 June 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 922023
24 March 1990
Certificate of Compliance
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1218312
23 March 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 336088
15 March 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 335832
17 June 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 496670
13 January 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 327870
31 December 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 327659
31 December 1988
Certificate of Compliance
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1041676
10 October 1988
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 531173
16 December 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 320300
16 December 1987
MARPOL Annex I Examination · Certificate of Compliance
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1005426
2 December 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 479305
4 May 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 308524
15 May 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 301978
15 May 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 983990
Deck/Cargo
Issued 23 March 1990
Resolved
FORWARD GUY WIRE ON STACK VENT WAS CORRODED TO THE POINT APPROX 25% OF THE CABLE DIAMETER REMAINED.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Fire Fighting
Issued 23 March 1990
Resolved
THE VERTICAL LOCKING DEVICE ON THE FORWARD FOAM MONITOR WAS FOUND INCAPABLEOF BEING OPERATED.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Electrical
Issued 23 March 1990
Resolved
UNGUARDED LIGHT GLOBE NOTED IN THE CARGO PUMP ROOM.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Documentation
Issued 23 March 1990
Resolved
UPON BOARDING THE VESSEL IT WAS NOTED THAT THE OPERATOR OF THE VESSEL DID NOT MATCH THE OPERATOR LISTED ON THE COFR. MASTER COULD NOT IMMEDIATELY PROVIDE EVIDENCE THAT ACTUAL VSL OPERATOR HAD FINACIAL COVERAGE.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Deck/Cargo
Issued 23 March 1990
Resolved
THE FLAME SCREEN COVER ON THE VENT FOR THE CARGO TANKS (MAST VENT) HAD CORRODED TO THE POINT APPROX 10% OF THE PLATE ITSELF WAS CORRODED AWAY. THE FLAME SCREEN ITSELF HAD BEEN HOLED IN CONSTRUCTION AND WAS ILL-FITTING,
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Construction/Loadline
Issued 23 March 1990
Resolved
THE FLAME SCREEN FOR THE VENT ON THE STBD FUEL OIL (DIESEL) TANK WAS FOUND ILL-FITTING AND IN NEED OF REPAIR. BECAUSE OF CONTAINMENT DESIGN REPAIRS COULD NOT BE ACCOMPLISHED WITHOUT HOTWORK.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Deck/Cargo
Issued 23 March 1990
Resolved
PROVIDE THREADED PLUGS FOR ALL VENT AND CARGO MANIFOLD CONTAINMENT DRIP PANS.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Fire Fighting
Issued 23 March 1990
Resolved
FIREMAN OUTFITS IMPROPERLY MAINTAINED AND INADEQUATELY SUPPLIED WITH REQUIRED EQUIPMENT.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Deck/Cargo
Issued 23 March 1990
Resolved
THE ALARM SYSTEM ON THE IGS INDICATING HIGH OXYGEN LEVEL IN THE IGS SYSTEM WAS NOTED AS INOPERATIVE IN THE CARGO CONTROL ROOM.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Deck/Cargo
Issued 23 March 1990
Resolved
REPLACE ALL GUY WIRES (CABLES) THAT SUPPORT THE MAST VENT. SEVERE CORROSIONNOTED ON ALL CABLES.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Documentation
Issued 23 March 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Unknown
Issued 23 March 1990
Resolved
UPON BOARDING THE VESSEL A CHECK WAS MADE OF PLASTICS RETAINED ON BOARD. THE VSL LAST POC WAS LA, WITH NO OFF LOAD OF PLASTICS, PRIOR POC INDONESIA OOA 18 FEB. VERY LITTLE PLASTICS ABOARD, 4 PLASTIC GBG BAGS & APPX 10 SM BGIN WASTE. APPX 30 CREW ON BOARD. PLASTICS EXIST IN FOOD STORES.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Unknown
Issued 23 March 1990
Resolved
TESTS REQUIRED BY 33 CFR 164.25 PRIOR TO ENTRY U.S. WATERS WERE NOT CONDUCTED WITHIN 12 HOURS OF ENTRY.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Navigation
Issued 13 January 1989
Resolved
VESSEL'S GYROCOMPASS WAS NOT MAINTAINED IN OPERABLE CONDITION AS REQUIRED BY 33 CFR 164.11 (R).
Condition: Unknown
Due 13 January 1989
Resolved 13 January 1989
Navigation
Issued 31 December 1988
Resolved
VESSEL'S AUTOMATIC RADAR PLOTTING AID (ARPA) WAS NOT MAINTAINED IN OPERABLE CONDITION AS REQUIRED BY 33 CFR 164.11(R).
Condition: Unknown
Due 31 December 1988
Resolved 31 December 1988