Records from 1985 to 1998. Most recent: inspection, 25 August 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 26
25 August 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 419513
24 August 1998
Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 797172
3 February 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 364433
3 February 1994
Tank Vessel Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1162293
1 April 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 357264
16 January 1993
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 538417
12 July 1992
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 351726
12 July 1992
Certificate of Compliance
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1260478
21 November 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 470244
8 November 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 941216
1 February 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 341477
1 February 1991
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1304080
17 January 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 335060
17 January 1990
Certificate of Compliance
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1217700
6 December 1989
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 334159
22 November 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 478714
15 May 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 513845
31 December 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 327648
31 December 1988
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1039156
4 October 1988
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 455233
20 May 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 323107
29 January 1988
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 499841
7 January 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 320486
7 January 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1319653
28 May 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 309183
15 May 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 301898
Fire Fighting
Issued 25 August 1998
Resolved
CANVAS SLEEVE ON EMERGENCY FIRE PUMP AIR SUPPLY.
Condition: Unknown
Due 14 September 1998
Resolved 26 August 1998
Engineering
Issued 25 August 1998
Resolved
HOLE IN STBD SIDE BUNKER CONTAINMENT AREA.
Condition: Unknown
Due 25 August 1998
Resolved 26 August 1998
Deck/Cargo
Issued 25 August 1998
Resolved
GASKET TORN ON BUTTERWORTH PLATE ON #1 CARGO TANK.
Condition: Unknown
Due 25 August 1998
Resolved 26 August 1998
Lifesaving
Issued 3 February 1994
Resolved
GENERAL CLEANING NEEDS TO BE CONDUCTED IN THE PUMP ROOM, FORWARD STORES, AND THE PANT LOCKER. ISSUED REQUIREMENT THAT ALL EXCESS ITEMS BE REMOVED.
Condition: Unknown
Due 3 February 1994
Resolved 3 February 1994
Lifesaving
Issued 3 February 1994
Resolved
THE VENTILATION MOTOR SHAFT IN THE PUMP ROOM DOES NOT HAVE A GUARD. ISSUED A REQUIREMENT TO HAVE ONE INSTALED.
Condition: Unknown
Due 3 February 1994
Resolved 3 February 1994
Deck/Cargo
Issued 3 February 1994
Resolved
FLAME SCREEN ON #3 PPBT WAS COVER WITH PAINT, #3 SCBT FWD HAD 2 LARGE HOLESIN THE FLAME SCREEN, #3 SCBT MID TANK WAS RUSTED THROUGH, #3 SPBT WAS RUSTED THROUGH. ISSUED REQUIREMENT THAT ALL SCREENS BE REPLACED.
Condition: Unknown
Due 3 February 1994
Resolved 3 February 1994
Electrical
Issued 3 February 1994
Resolved
LIGHTS IN THE PUMP ROOM HAD A NUMBER OF PROBLEMS. 1, SEVERAL OF THE LIGHTS WERE MISSING GROUNDING STRAPS. 2, ON THE 1ST AND 3RD LEVEL LIGHTS WERE TIDED UP WITH WIRE. REPLACE ALL GROUNDING STRAPS, REPLACE THE WIRE WITH BOLTS.
Condition: Unknown
Due 3 February 1994
Resolved 3 February 1994
Fire Fighting
Issued 3 February 1994
Resolved
THE FIRE PLANS AND MASTER FIRE PLAN NEED TO BE UPDATED. THE FIRE PLANS SHOWTHE INTERNATIONAL SHORE CONNNECTION AS BEING STORED IN THE MID SHIP STORES LOCKER. THERE ARE TWO AND BOTH ARE STORED IN THE CARGO CONTROL ROOM. THE MASTER SHOWS THREE, TWO IN THE CARGO ROOM AND ONE AT MID SHIPS.
Condition: Unknown
Due 3 February 1994
Resolved 3 February 1994
Lifesaving
Issued 3 February 1994
Resolved
THE STEAM LINE COVER IN THE FORWARD STORES IS MISSING, NEEDS TO BE REINSTALLED.
Condition: Unknown
Due 3 February 1994
Resolved 3 February 1994
Fire Fighting
Issued 3 February 1994
Resolved
NUMBER ONE FIRE MONITOR NEEDS TO BE REPAIRED/REPLACE. LEAKS IN SEVERAL AREAS NEAR THE NOZZLE.
Condition: Unknown
Due 3 February 1994
Resolved 3 February 1994
Deck/Cargo
Issued 3 February 1994
Resolved
THE STEAM LINE GOING TO THE DECK WINCH HAD BEEN REPAIRED OR REPLACED. UNKNOWN AS TO THE WHEN, WHERE, DATE, OR TIME. HOWEVER, THE UNDERSIDE WELDING WAS NEVER COMPLETED.
Condition: Unknown
Due 3 February 1994
Resolved 3 February 1994
Deck/Cargo
Issued 12 July 1992
Resolved
PROVE PROPER OPERATION OF HIGH TEMP ALARM/SHUTDOWN TO INERT GAS SYSTEM.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Documentation
Issued 17 January 1990
Resolved
OTP WERE NOT IN ORDER LISTED OR GIVEN A CROSS REFERENCE IAW 33CFR155.750(A)
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Documentation
Issued 17 January 1990
Resolved
OTP LINE DIAGRAM DID NOT SHOW TANK VENTS IAW 33 CFR 155.750(A)(1)(I)
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Documentation
Issued 17 January 1990
Resolved
OTP DID NOT CONTAIN CARGO INFORMATION IAW 33 CFR155.750(A)(1)(II).
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Engineering
Issued 7 January 1988
Resolved
VESSEL DID NOT HAVE A STANDARD DISCHARGE CONNECTION AS REQUIRED BY 3 CFR 155.430.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Deck/Cargo
Issued 28 May 1986
Resolved
MAKE PERMINANT REPAIRS TO F/O AND L/O VENTS AND FLAME SCREENS ON STBD SIDE.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Deck/Cargo
Issued 28 May 1986
Resolved
MAKE PERMINANT REPAIRS ON PORT IGS BLOWER/WOOD BLOCK HOLDING SOLENOD SWITCH, IN THE OPEN POSITION
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Construction/Loadline
Issued 28 May 1986
Resolved
MAKE REPAIRS TO BALLAST PUMP IN PUMPROOM. HAS A SOFT PATCH ON THE DIS- CHARGE LINE.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Deck/Cargo
Issued 28 May 1986
Resolved
MAKE REPAIRS TO SOFT PATCH ON STRAINER LINE OF #1 CARGO PUMP ON DISCHARGE SIDE.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Deck/Cargo
Issued 28 May 1986
Resolved
MAKE PERMINANT REPAIRS TO IGS WATER FEED LINES
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Deck/Cargo
Issued 28 May 1986
Resolved
SALAS 74, REG.19, EXCESS LEAK IN HYDRALIC CONTROL PANEL FOR # 5 PORT TANK.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Deck/Cargo
Issued 28 May 1986
Resolved
MAKE PERMINANT REPAIRS TO FLANGE FEED LINE JUST AFT OF STOP VALVE TO #5 PORT TANK.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Construction/Loadline
Issued 28 May 1986
Resolved
SOLAS 74 REG #19, SUPPORT WIRES TO FWD MAST ARE BADLY WASTED AWAY AT DECK.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Electrical
Issued 28 May 1986
Resolved
SOLAS 74 REG. #19, WATER IN EMERGENCY LIGHT GLOBE, LOCATED ABOVE BOW LIFE RAFT.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Deck/Cargo
Issued 15 May 1985
Resolved
MAKE PERMANENT REPAIRS OR REPLACE THE FIFTH EXPANSION JOINT IN #1 CARGO LINE FOWARD ON THE DECK HOUSE. PRIOR TO CARGO TRANSFER IN NEXT U.S. PORT.
Condition: Unknown
Due 15 May 1985
Resolved 15 May 1985