Records from 1985 to 1998. Most recent: inspection, 20 May 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 34
20 May 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 416454
20 May 1998
Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1126379
5 January 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 643542
18 March 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 162659
8 March 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 401254
14 February 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 121435
28 January 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 441913
28 January 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 494682
23 December 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 460202
22 September 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 383221
17 April 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 643534
11 April 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 58071
6 February 1995
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 836985
1 February 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 439457
7 July 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 368342
28 February 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 364929
28 February 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1165076
26 September 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 495722
26 September 1993
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1151653
12 April 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 831963
23 March 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 841669
29 January 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 453714
28 August 1992
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 354213
20 July 1992
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1248012
17 June 1992
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 949873
29 April 1992
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 529980
31 August 1991
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1251878
11 June 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 891590
6 June 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 330900
6 June 1989
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 887585
19 October 1987
Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1016121
22 August 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 311002
26 June 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296153
8 August 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 303573
Fire Fighting
Issued 20 May 1998
Resolved
LOW PRESSURE INDICATOR ON ONE SCBA NOT WORKING PROPERLY.
Condition: Unknown
Due 20 May 1998
Resolved 28 May 1998
Accommodation/Occupational Safety
Issued 20 May 1998
Resolved
THE HOSPITAL SPACE HAD NO HOT WATER.
Condition: Unknown
Due 20 May 1998
Resolved 28 May 1998
Lifesaving
Issued 8 March 1997
Resolved
VESSELS STARBOARD SIDE LIFEBOAT RELEASING GEAR WAS INOPERABLE.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Engineering
Issued 26 September 1993
Resolved
MAKE PERMANENT REPAIRS TO CONTAINMENT FOR DIESEL FUEL TANK, LOCATED STBD SIDE MAIN DECK NEAR FORWARD END OF HOUSE. TO BE COMPLETED PRIOR TO ARRIVALNEXT U.S. PORT.
Condition: Unknown
Due 26 September 1993
Resolved 26 September 1993
Lifesaving
Issued 26 September 1993
Resolved
PROVIDE A SOLAS INFLATABLE LIFERAFT AT THE BOW PRIOR TO DEPARTURE THE PORT OF PHILADELPHIA TO REPLACE THE RAFT LOST IN HEAVY WEATHER. (ON ORDER WITH LRI IN TRENTON, NJ)
Condition: Unknown
Due 26 September 1993
Resolved 26 September 1993
Construction/Loadline
Issued 26 September 1993
Resolved
PROVIDE WRITTEN EVIDENCE THAT THE CLASSIFICATION SOCIETY HAS EXAMINED THE FRACTURE IN THE LNOGITUDINAL BULKHEAD BETWEEN #3C & #3S (FRAME 80.5 BELOW 7TH LONGITUDINAL) AND A COPY OF ACTIONS TAKEN AND TO BE TAKEN TO REPAIR THEFRACTURE. TO BE COMPLETED PRIOR TO DEPARTURE PORT OF PHILADELPHIA.
Condition: Unknown
Due 26 September 1993
Resolved 26 September 1993
Unknown
Issued 20 July 1992
Resolved
Renew deck gratings in way of #1, 2, 3, and 4 deck foam monitors.
Condition: Unknown
Due 20 July 1992
Resolved 20 July 1992
Deck/Cargo
Issued 20 July 1992
Resolved
Install pressure/vacuum relief valves for the individual cargo tanks so that they may not be isolated from the tank with a stop valve. Present installation of common header vent system allows each tank to be isolated from the system thereby eliminating the P/V valve from the isolated tank.
Condition: Unknown
Due 20 July 1992
Resolved 20 July 1992
Deck/Cargo
Issued 20 July 1992
Resolved
Repair or replace the open/close valve indicators in the cargo control roomfor the following monitors: 1S, 3P, 3S, 4P, 4S, 6P and 8S.
Condition: Unknown
Due 20 July 1992
Resolved 20 July 1992
Engineering
Issued 20 July 1992
Resolved
Replace the flame screens for the port fuel oil sludge tank and the port diesel oil tank.
Condition: Unknown
Due 20 July 1992
Resolved 20 July 1992
Fire Fighting
Issued 20 July 1992
Resolved
Calibrate the combustible gas indicators.
Condition: Unknown
Due 20 July 1992
Resolved 20 July 1992
Deck/Cargo
Issued 17 June 1992
Resolved
AFTER CARGO LINE #1 REPAIRED, HYDROSTATICALLY TEST TO 225psi(15kg/cm3) ALL DECK CARGO PIPES. 33CFR156.170(c)
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Deck/Cargo
Issued 17 June 1992
Resolved
PRIOR TO RETURN TO US WATERS, MAKE PERMANENT REPAIRS TO CARGO LINE #1 AND PROVIDE DOCUMENTATION AS TO WHAT REPAIRS MADE. 33CFR156.170
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Deck/Cargo
Issued 26 June 1986
Resolved
DETER ORATED FLAME SCREENS ON VACUME RELIEFS VALVE TO BE CORRECTED PRIOR TOFUTURE US PORT ENTRY.
Condition: Unknown
Due 26 June 1986
Resolved 26 June 1986
Deck/Cargo
Issued 26 June 1986
Resolved
FIXED CONTAINMENT NOT INSTALLED AT BUNKER FILL CONNECTION TO BE PROVIDED PRIOR TO NEXT US PORT ENTRY.
Condition: Unknown
Due 26 June 1986
Resolved 26 June 1986
Navigation
Issued 26 June 1986
Resolved
TIDAL CURRENT TABLES NOT AVAILABLE TO BE PROVIDED PRIOR TO NEXT US PORT ENTRY.
Condition: Unknown
Due 26 June 1986
Resolved 26 June 1986
Fire Fighting
Issued 26 June 1986
Resolved
ALL PAINT TO BE STORED IN A SPACE PROTECTED BY A FIXED FIREFIGHTING SYSTEM PRIOR TO ENTRY INTO US WATER AFTER: 01JAN87
Condition: Unknown
Due 26 June 1986
Resolved 26 June 1986