MAURY USCG vessel records Sign in
← All vessels

STETSON RAE

STETSON RAE is a 2001 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 2001, most recently in November 2025, along with 17 deficiencies and 1 casualty investigation in 2011.

Records from 2001 to 2025. Most recent: inspection, 25 November 2025.

Built
2001
Last inspected
25 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8968399 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDQ2791
Flag
UNITED STATES
366813470
Maury page id
psix-22466

Inspections, by type

…with no type recorded4
Years with a record 19 calendar years (2001–2025)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)128.1 ft × 30.1 ft × 12.2 ft
Registered tonnagegross 71 / net 48
ITC dimensions (L × B × D)128.1 ft × 30.1 ft × 12.2 ft
ITC tonnagegross 278 / net 83
BuilderQUEEN CRAFT SHIPYARD · PANAMA CITY, FL, UNITED STATES · built 2001
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLOS ANGELES, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Regulatory (Subpart C or D), Gross Ton
278 - Convention (Subpart B), Gross Ton
48 - Regulatory (Subpart C or D), Net Ton
83 - Convention (Subpart B), Net Ton
128 - Dead Weight, Ton
128 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ2792MMSI 366813470 · active · compulsorily equipped · granted 28 March 2025, expires 28 March 2035
WDA4820MMSI 366813470 · cancelled · compulsorily equipped · granted 14 May 2021, cancelled 24 March 2025
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISS JOSIE Offshore Supply Vessel · MISLE 52744 · 17 September 2002 · activity 1676843FAST SCOUT Passenger (Inspected) · MISLE 466614 · 17 September 2002 · activity 1676843

Inspection history · 32

25 November 2025 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8265239
18 April 2025 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8112927
22 October 2024 Drydock Exam · Examination of Repairs · Deficiency Check · Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8020335
1 November 2022 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7587294
13 November 2020 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7094577
7 October 2020 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7073063
12 August 2020 DAPI Audit · In-Service Inspection · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7026351
11 December 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6863989
31 October 2018 Examination of Repairs · Hull Examination · Annual Inspection · DAPI Audit · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6573351
22 December 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6328875
16 November 2017 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6308349
9 November 2016 Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6037713
24 October 2016 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6027083
23 September 2015 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5727089
10 January 2012 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4222474
8 December 2011 Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4204584
11 August 2011 Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 4112749
21 August 2008 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3305681
25 September 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3065648
30 July 2007 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3014348
8 June 2006 Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2653602
25 May 2006 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2711765
12 July 2005 Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2423812
1 July 2004 Annual Inspection · Internal Structural Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2117758
22 June 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2106627
19 August 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1880672
18 August 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1879523
7 August 2003 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1869065
19 September 2002 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1678987
17 September 2002 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1676843
15 July 2002 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1646384
28 July 2001 Inclining Experiment · Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1465068

Deficiency record · 17

01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 18 April 2025 Resolved
When, in accordance with §178.210 of this chapter, a vessel must be provided with a stability letter. The vessel currently does not have a current stability letter on board. Vessel to operate on the previous stability letter, and deck cargo is restricted to a maximum of 10 long tons.
Action required: 705 - Other - as specified
Due 18 April 2025
Resolved 28 April 2025
Resolution: Recieved proof of updated stability letter.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. MI identified numerous electrical items to be completed following recent re-power.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2025
Resolved 8 May 2025
Resolution: Work complet for vessel repower. All electrical back to standard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 December 2019 Resolved
Stbd main engine was found inoperable due to major oil leak at oil filter. Prove proper operation of stbd outboard engine to the satisfaction of attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 25 December 2019
Resolved 12 December 2019
Resolution: Tech repaired engine. Replace multiple cylinder sleeves and a turbo. MI observed operation of main. Deficiency cleared. Vsl rep to provide tech report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 October 2018 Resolved
A vessel of more tham 65' in legth is required 2 fixed power bilge pumps. The main bilge pump has a leaking seal and it is not operable as required by 46CFR182.500.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 November 2018
Resolution: Bilge pump shaft seal was replaced in kind. Bilge pump was witnessed to operate and water was taken through the sea chest pick up and discharged over the side. Flow and operation were sat.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 December 2017 Resolved
Emergency lighting in galley and A/C room not working properly. Fix or replace.
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 22 December 2017
Resolution: Verified that emergency lighting in galley and A/C room working properly.
Stability › Watertight Integrity › General
Issued 5 December 2017 Resolved
Starboard side engine room escape hatch has crack in way of knife edge and frame. Replace hatch.
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 22 December 2017
Resolution: Verified installation of new watertight hatch.
Engineering › Bilge Water Management System › Strainer
Issued 5 December 2017 Resolved
Bilge suction needs to be fitted with a suitable having an open area not less than three times the area of the bilge pipe.
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 22 December 2017
Resolution: Verified installation of proper bilge suction foots.
Lifesaving › Lifefloat › Lifeline
Issued 9 November 2016 Resolved
Life Line needed to be renewed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 November 2016
Resolved 9 November 2016
Resolution: Lifefloat life line was renewed.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 28 September 2015 Resolved
Fire dampers were not able to close all the way. Repair fire dampers to be operable IAW 46 CFR 182.465
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2015
Resolved 28 September 2015
Resolution: Fire dampers were repaired and tested on site.
Personnel › Manning/Qualifications › First Aid Certified Personnel
Issued 8 June 2006 Resolved
Provide evidence that crew members hold first aid qualifications or received first aid training as required by NVIC 1-91.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2006
Resolved 8 June 2006
Resolution: Vessel crew provided first aid and cpr cards for 50% of the crew prior to departure from port and to the satisfaction of the attending marine inspector.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 8 June 2006 Resolved
Prove operation of deck ventilation closures as per 46 CFR 182.465 to the satisfaction ofthe attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2006
Resolved 8 June 2006
Resolution: Vessel crew demonstrated proper operation of deck ventilation shutdowns to the satisfaction of the attending marine inspector.
Engineering › Fuel Oil Service System › Hose
Issued 8 June 2006 Resolved
Repair or renew leaking fuel oil piping as per 46 CFR 182.710 to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 6 July 2006
Resolution: Vessel crew replaced leaking fuel line returning to port fuel tank to the satisfaction of the attending marine inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 8 June 2006 Resolved
Remove all unnecessary item accumulated in the area containing the fixed CO2 system as per 46 CFR 176.800 to the satisfaction of the attending marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 June 2006
Resolved 8 June 2006
Resolution: Vessel crew removed items from space containing CO2 bottles/system to the satisfaction of the attending marine inspector.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 8 June 2006 Resolved
Prove proper operation of the vessel's Single Side Band communications system as required by 46 CFR 184.502 to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2006
Resolved 8 June 2006
Resolution: Crew demonstrated proper operation of the vessel''''s SSB radio to the satisfaction of the attending marine inspector.
Engineering › Steering Gear System
Issued 18 August 2003 Resolved
Repair small hydraulic leak in steering system in steering compartment, last 90 degree fitting after bulkhead. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 18 September 2003
Resolved 19 August 2003
Resolution: Owner repaired small hydraulic leak in steering system.
Communications › Alarms/Indicators
Issued 18 August 2003 Resolved
Repair generator room bilge alarm. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 18 September 2003
Resolved 19 August 2003
Resolution: Owner repaired generator room bilge alarm.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 August 2003 Resolved
Fasten battery box covers in generator room IAW 46 CFR 183.350. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 18 September 2003
Resolved 19 August 2003
Resolution: Owner refastened battery box covers in generator room.

Casualty record · 1

26 April 2011Routine · role: Involved in a Marine Casualty · activity 3995741
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

JUDY D (2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.