Records from 1985 to 2001. Most recent: operational control imposed, 5 July 2001.
Inspection history · 14
5 July 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 291580
2 December 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 423260
15 December 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 410900
26 January 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 387240
3 January 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 373656
19 July 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 645586
13 July 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 368309
3 May 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 358028
6 January 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 348017
6 March 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 342232
29 November 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 333909
26 October 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 326425
27 November 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 312918
19 November 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 305337
Engineering
Issued 5 July 2001
Resolved
No.1 generator's F/O injection pumps #'s 2 & 4 leaking excessively. Repair prior to departure.
Condition: Unknown
Due 5 July 2001
Resolved 13 July 2001
Engineering
Issued 5 July 2001
Resolved
No.1 generator's F/O filter housing leaking excessively. Repair prior to departure.
Condition: Unknown
Due 5 July 2001
Resolved 13 July 2001
Engineering
Issued 5 July 2001
Resolved
No.2 generator's #'s 1,2,3,4 F/O injection pumps leaking excessively. Repair prior to departure.
Condition: Unknown
Due 5 July 2001
Resolved 13 July 2001
Engineering
Issued 5 July 2001
No resolution recorded
ALL 3 GENERATORS HAVE MINOR FUEL LEAKS ON LOW PRESSURE FUEL SYSTEM. REPAIRALL FUEL LEAKS PRIOR TO RETURNING TO U.S. WATERS
Condition: Unknown
Due 15 July 2001 — due date passed with no resolution recorded
Engineering
Issued 5 July 2001
Resolved
No.3 generator has F/O leaks on F/O pump and supply pipe to F/O supply header.
Condition: Unknown
Due 15 July 2001
Resolved 16 July 2001
Deck/Cargo
Issued 26 January 1996
Resolved
PRIOR TO NEXT U.S. PORT PROVIDE CLASS SOCIETY REPORT OF SATISFACTORY INSPECTION OF CARGO HATCH HYDRAULIC SYSTEM AND REPAIR LEAKS IN CARGO HATCH HYDRAULIC SYSTEM.
Condition: Unknown
Due 1 August 1996
Resolved 1 August 1996
Navigation
Issued 3 May 1993
Resolved
CHART OF THE AREA TRANSITED, 11370 WAS NOT CURRENTLY CORRECTED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 February 1996
Resolved 5 February 1996
Navigation
Issued 19 November 1985
Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT THE STEERING GEAR OPERATING AND CHANGEOVER INSTRUCTIONS AND DIAGRAM REQ BY 33 CFR 164.35 (K) WERE NOT POSTED ON THE BRIDGE OR IN THE STEERING COMPARTMENT.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Documentation
Issued 19 November 1985
Resolved
A VIOLATION OF 155.740 IN THAT THE OTP REQ BY 33 CFR 155.720 WERE NOT AVAILABLE FOR INSPECTION BY THE COTP. THE VSL DID NOT HAVE ANY OTP O/B.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985