Records from 1984 to 1995. Most recent: operational control imposed, 8 February 1995.
Inspection history · 30
8 February 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 484969
19 December 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 475430
30 August 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 94200
1 August 1994
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1431394
1 June 1994
Tank Vessel Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407328
31 May 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 367411
28 July 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 673527
26 July 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 488182
2 July 1993
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1157622
4 December 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 355067
16 September 1992
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 354789
16 September 1992
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1262010
4 May 1992
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 350502
20 March 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 514938
14 November 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 667435
23 September 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 346115
8 August 1991
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 942334
17 July 1991
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1252432
23 October 1990
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 917701
2 July 1990
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1227286
9 January 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 502484
30 July 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 331819
30 July 1989
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1196667
11 January 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 518185
23 May 1988
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1194187
14 June 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 492282
17 March 1987
Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1323561
21 May 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 535305
22 July 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 303322
22 October 1984
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 298458
Fire Fighting
Issued 1 June 1994
Resolved
PROVIDE ISOLATION VALVE FOR FOAM TANKS FOR TESTING PURPOSES OR PROVIDE APPROVED TEST PROCEDURES FROM CLASS SOCIETY TO TEST FOAM SYSTEM. (NOTE: PLANS SHOULD ALSO INDICATE CHANGES). MUST BE COMPLETED PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 1 June 1994
Resolved 1 June 1994
Fire Fighting
Issued 1 June 1994
Resolved
REPAIR LEAKING VALVE TO PORT SIDE FOAM MONITOR PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 1 June 1994
Resolved 1 June 1994
Fire Fighting
Issued 1 June 1994
Resolved
MAKE PERMANENT REPAIRS TO MAIN FOAM LINE SOFT PATCH IN FOAM ROOM PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 1 June 1994
Resolved 1 June 1994
Documentation
Issued 16 September 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992
Construction/Loadline
Issued 16 September 1992
Resolved
GAS FREE AND MAKE A BALLAST TANK AND THE PUMPROOM AVAILABLE FOR AN INTERNALEXAM. 46USC3714(A)(2)
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992
Navigation
Issued 16 September 1992
Resolved
UPDATE ADMIRALTY CHART 485 WITH THE LATEST CORRECTIONS._x001C_ 33CFR164.33_x001C_ _x001C_
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992
Fire Fighting
Issued 16 September 1992
Resolved
MAKE PERMENENT REPAIRS TO THE EMERGENCY FIRE PUMP ENGINE WHICH HAS TEMPORARY REPAIR ON THE EXHAUST MANIFOLD. SOLAS CHII,PART C REG. 3.3.
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992
Deck/Cargo
Issued 16 September 1992
Resolved
MAKE PERMENENT REPAIRS TO THE IGS LINE TO #1 C TANK DOME WHICH HAS A SOFT PATCH (FIBERGLASS). 46CFR32.53
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992
Documentation
Issued 16 September 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992
Deck/Cargo
Issued 16 September 1992
Resolved
REPAIR THE NON-FUNCTIONAL MAIN DECK MECHANICAL SCUPPER CLOSEURES. 33CFR155.310(A)(3).
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992
Deck/Cargo
Issued 16 September 1992
Resolved
REPAIR OR REPLACE THE O2 METERS AND COMBUSTIBLE GAS DETECTORS WHICH HAVE LOW BATTERIES AND BAD SENSORS. 46CFR32.53-65
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992
Deck/Cargo
Issued 16 September 1992
Resolved
REPLACE THE SIGHT GLASS WHICH IS CRACKED AT THE IGS P.V. BREAKER._x001C_ 46CFR32.53
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992
Fire Fighting
Issued 16 September 1992
Resolved
COMPLETE REPAIRS TO THE LEAKING DRESSOR COUPLINGS IN FIRE MAIN WHERE REPAIRS HAVE BEGUN. SOLAS II/2
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992
Deck/Cargo
Issued 16 September 1992
Resolved
OBTAIN CLASS SOCIETY APPROVAL FOR THE IGS MANUALS ON BOARD._x001C_ 46CFR32.53
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992
Navigation
Issued 4 May 1992
Resolved
A VIO OF 33 C.F.R.164.11(Q) IN THAT THE TESTS REQ BY 33 C.F.R. 164.25(A) WERE NOT CONDUDUCTED
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Unknown
Issued 4 May 1992
Resolved
A VIO OF 33 C.F.R. 164.210 IN THAT THE VSL FAILED TO GIVE ADVANCE NOTIFICATION OF THE VSL'S LIGHTERING
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Navigation
Issued 4 May 1992
Resolved
A VIO OF 33 C.F.R. 164.11(r) IN THAT THE EQUIPMENTREQ BY 33 C.F.R. 164.30 WAS NOT MAINTAINED IN PROPER WORKING CONDITION.
Condition: Unknown
Due 5 May 1992
Resolved 18 May 1992
Navigation
Issued 17 July 1991
Resolved
UPDATE ADMIRALITY COAST PILOT (VOL 69) PRIOR TO DEPARTURE PHILADELPHIA.
Condition: Unknown
Due 17 July 1992
Resolved 8 August 1991
Engineering
Issued 17 July 1991
Resolved
PRIOR TO RETURN TO U.S. WATER VESSEL MUST REPLACE ALL FLAME SCREENS FOR ENGINEROOM VENTS LOCATED ON THE WEATHER DECK.
Condition: Unknown
Due 17 July 1992
Resolved 8 August 1991
Navigation
Issued 17 July 1991
Resolved
UPDATE TURNING CIRCLE TO INDICATE FULL AND HALF SPEED PRIOR RETURN TO U.S. WATERS. ALL MANEUVERING INFO SHOULD BE FOR NORMAL AND BALLAST LOADS.
Condition: Unknown
Due 17 July 1991
Resolved 17 July 1991
Engineering
Issued 17 July 1991
Resolved
PRIOR TO RETURN TO U.S. WATER VESSEL MUST REPLACE ALL FLAME SCREENS FOR ENGINEROOM VENTS LOCATED ON THE WEATHER DECK.
Condition: Unknown
Due 17 July 1992
Resolved 8 August 1991
Fire Fighting
Issued 17 July 1991
Resolved
INSTALL GASKETS ON FIRE HOSES WHERE MISSING
Condition: Unknown
Due 17 July 1992
Resolved 8 August 1991
Accommodation/Occupational Safety
Issued 17 July 1991
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 July 1992
Resolved 8 August 1991
Engineering
Issued 17 July 1991
Resolved
PRIOR TO RETURN TO U.S. WATERS REPAIR OILY WATER SEPARATOR. RETAIN OILY WASTE ONBOARD UNTIL SEPARATOR IS REPAIRED OR PUMPING TO A APPROVED FACILITYCAN BE DONE.
Condition: Unknown
Due 17 July 1991
Resolved 17 July 1991
Deck/Cargo
Issued 17 July 1991
Resolved
PROVIDE MECHANICAL MEANS OF CLOSURE FOR BUNKER CONTAINMENT WHERE MISSING.
Condition: Unknown
Due 17 July 1992
Resolved 8 August 1991
Navigation
Issued 23 October 1990
Resolved
REPAIR 10CM RADAR TO PREVENT INTERMITTENT FAULT.
Condition: Unknown
Due 23 October 1990
Resolved 23 October 1990
Deck/Cargo
Issued 2 July 1990
Resolved
PRIOR TO RETURN TO U.S WATERS VESSEL MUST HAVE MECHINCAL MEANS OF CLOSURE FOR THE STBD. BUNKERS AND FUEL VENT CONTAINMENT.
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Engineering
Issued 2 July 1990
Resolved
PRIOR TO RETURN TO U.S. WATERS VESSEL MUST REMOVE OIL FROM THE ENGINE ROOM BILGES.
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Deck/Cargo
Issued 2 July 1990
Resolved
PRIOR TO TRANSFER OF CARGO IN THE U.S. WATERS THE VESSEL MUST HAVE REPLACEDOR MAKE PERMANENT REPAIRS TO ALL THREE CARGO LINES.
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Deck/Cargo
Issued 2 July 1990
Resolved
PRIOR TO RETURN TO U.S. WATERS THE MUST REPAIR OR REPLACE IGS LINE WHERE PACTHED,AND TO CLEAN OR RENEW SIGHT GLASS TUBES FOR THE P.V. BREAKER ON THEIGS LINE.
Condition: Unknown
Due 2 July 1990
Resolved 2 July 1990
Documentation
Issued 22 October 1984
Resolved
VESSEL MUST PROVIDE EVIDENCE OF ACCEPTENCE OF AS REQUIRED BY CFR 157.118 (B).
Condition: Unknown
Due 22 October 1984
Resolved 22 October 1984
Documentation
Issued 22 October 1984
Resolved
VESSEL MUST PROVIDE ONBOARD A CRUDE OIL WASHING OPERATIONS MANUAL AS REQUIRED BY 33 CFR 157.118(A).
Condition: Unknown
Due 22 October 1984
Resolved 22 October 1984