MAURY USCG vessel records Sign in
← All vessels

HERON

HERON is a 1975 freight ship. The Coast Guard has recorded 72 inspections since 1985, most recently in January 2012, along with 50 deficiencies — 2 with no resolution recorded — and 14 operational controls.

Records from 1985 to 2012. Most recent: inspection, 17 January 2012.

Built
1975
Last inspected
17 January 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7380760 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224683
Flag
PORTUGAL
—
Maury page id
psix-224683

Inspections, by type

…with no type recorded49
Years with a record 24 calendar years (1985–2012)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it38633 - Dead Weight, Ton
49430 - Displacement, Ton
11300 - Convention (Subpart B), Net Ton
25919 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 72

17 January 2012 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4226297
16 January 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4225514
14 January 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4221975
19 September 2011 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 4149398
23 February 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3950598
21 February 2011 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3948029
3 December 2009 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3640704
3 December 2009 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3641518
30 March 2009 PII Safety Exam · ISPS III Exam · COE-Dockside
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3442607
27 December 2008 ISPS I Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3385286
17 September 2008 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3326613
15 August 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3298865
15 August 2008 PI Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3299049
14 August 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3304665
11 August 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3295586
25 February 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3152882
21 May 2007 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2936124
23 April 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2913405
7 February 2007 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2868368
18 October 2006 ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2803120
9 June 2006 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2674915
13 April 2006 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2624232
28 November 2005 Ballast Water Examination
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2541808
15 August 2005 NPV Safety Exam · ISPS III Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2463594
15 January 2005 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2275527
28 December 2004 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2265735
24 September 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2203938
24 September 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2228434
1 September 2004 Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2183164
9 August 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2161155
27 July 2004 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2147769
27 July 2004 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2234720
4 May 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2059070
20 April 2004 MARPOL Annex V Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2048570
20 April 2004 MARPOL Annex V Examination · Annual Inspection · Security Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2049297
1 March 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2016781
4 December 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1960919
24 March 2003 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1762615
13 February 2003 Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1725393
24 November 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1710172
20 November 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1709712
18 November 2001 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 295554
9 July 2001 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 291711
20 June 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 278791
1 December 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 435368
2 May 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 430793
11 December 1997 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 410872
28 November 1997 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 410447
20 September 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 395679
18 March 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2142
11 March 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 388746
2 March 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 388396
1 September 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358895
25 August 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 83796
23 August 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 382020
29 June 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 359168
17 July 1992 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 647547
17 July 1992 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 686052
24 June 1992 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 351567
2 May 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 343484
9 March 1990 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 335749
25 November 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 327081
24 April 1988 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 322998
19 April 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 482252
8 December 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 320156
28 June 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 530395
10 June 1987 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 522630
23 October 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 312269
6 October 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 311807
27 August 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 311103
5 June 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 309297
14 February 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 300382

Deficiency record · 50

Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 17 January 2012 Resolved
2540 - Emergency Preparednes -DUE TO IMPPROPER CHARGING, BATTERIES PROVIDED FOR EMERGENCY SOURCE OF POWER MUST UNDERGO A TEST TO ENSURE ADEQUACY. EMERGENCY SOURCE OF POWER SHALL BE SUFFICIENT TO SUPPLY ALL SERVICES NECESSARY FOR THE SAFETY OF ALL ON BOARD IN AN EMERGENCY. SOLAS 60 Ch 2/26 deficiency to be cleared prior to departure from port to the satisfaction of the Coast Guard
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2012
Resolution: A test was performed of they ship''''s emergency batteries. The test included a walk around of the ship''''s deck, passageways, bridge, and engine room to check for illumination of emergency lights. A test of the ships general alarm was also conducted.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 17 January 2012 Resolved
0610 - Lifeboats - CREW IS UNABLE TO GET ENGINE IN STARBOARD LIFEBOAT STARTED. BEFORE SHIP LEAVES PORT AND AT ALL TIMES DURING VOYAGE ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. SOLAS 09 Con Ed III/20.2 Deficiency is to be be cleared prior to vessel's departure from port to the satisfaction of the Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2012
Resolution: The port and starboard lifeboat engines were started up immediately during follow up examination.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 17 January 2012 Resolved
0740 - Pumps - CREW IS UNABLE TO GET EMERGENCY FIRE PUMP STARTED IMMEDIATELY. FIRE FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. SOLAS 09 CONED II/2 14.2.1.1 Deficiency is to be cleared prior to departure from port to the satisfaction of the Coast Guard
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2012
Resolution: The battery used to start the emergency fire pump has been replaced. The emergency fire pump was started immediately and ran without problems.
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 January 2012 No resolution recorded
0730 - Appliances (general equipment) - THE EMERGENCY FUEL SHUTOFF VALVE FOR THE EMERGENCY FIRE PUMP WAS FOUND TO BE INOPERABLE. VALVE STEM IS BROKEN. NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITMES COVERED BY THE SURVEY. SOLAS 09 Con Ed I/11B Deficiency is to be corrected prior to next US port after sailing foreign to the satisfaction of Class
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 17 January 2012 No resolution recorded
0950 - Electric Equipment in General - A DISTRIBUTION PANEL LOCATED AFT IN THE PORT TUNNEL IS MISSING FACE PLATE AND BLANK COVERS. THIS POSES A RISK OF ELECTROCUTION. ELECTRICAL APPARATUS SHALL BE CONSTRUCTED AND INSTALLED TO REMOVE DANGER OF INJURY IN ORDINARY HANDLING. SOLAS 60 Ch. 2/27a The deficiency is to be cleared prior to next US port after sailing foreign to the satisfaction of Class
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving › Lifeboat › Handholds/Handrails
Issued 23 February 2011 Resolved
During abandon ship drill, while the port side lifeboat was being lowered, the tricing pendant was tangled and caught in a hand rail on the top of the lifeboat. This caused an approximate 3 foot section of the hand rail to break off the lifeboat. SOLAS 60 Ch. 1/11. Code 70a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 February 2011
Resolution: Repaired life boat broken hand rail approx. 3 foot section has now been replaced as per original.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 23 February 2011 Resolved
Vessel's Safety Equipment [name withheld] states both vessels lifeboats are 50 person capacity. The lifeboats only have a capacity of 32 persons which does not match the Equipment Certificate. SOLAS 60 Ch 1/12(a)(iii). Code 70a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 February 2011
Resolution: Changed certificate to reflect total capacity of port and starboard life boats
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 15 August 2008 Resolved
On 14Aug08, the vessel experienced a Power Loss that resulted in the vessel touching bottom at mm 130, Lower Mississippi River, due to the automatic slow down for the main engine being activated.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2008
Resolved 15 August 2008
Resolution: Received a class report from DNV stating that the slow down device was activated from a rise in M/E cooling water temperature, which was caused by air in the sea suction line. No damage or leakages, M/E tested an found satisfactory.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 23 April 2007 Resolved
Ship's crew failed first attempt at boat lowering drill (port side lifeboat). Must conduct satisfactory boat drill prior to vessel's departure. SOLAS 74/78 (2004ed) III/19.3.3 17c
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2007
Resolved 23 April 2007
Resolution: Deficiency was corrected on the spot.
Lifesaving › Lifeboat › Handholds/Handrails
Issued 23 April 2007 Resolved
Repair grab line attachments on port lifeboat where grab line has detached from lifeboat hull. SOLAS 60 III/11.a.xvi 50a/b
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 21 May 2007
Resolution: Vsl submitted digital photo showing repaired grab line attachments.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 23 April 2007 Resolved
Repair broken emergency embarkation light assembly at port side lifeboat station. SOLAS 60 III/19 50a/b
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 21 May 2007
Construction/Loadline › Markings › Load Line Assigning Authority Mark
Issued 13 April 2006 Resolved
Vessel's portside loadline is permanently marked V. N. Loadline Certificate shows that Loadline should be marked N. V. To the satisfaction of Class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 June 2006
Resolution: Received class report from DNV satisfying requirement.
Engineering › Steering Gear System › Pump
Issued 13 April 2006 Resolved
While conducting steering test it was discovered that when both steering pumps are running in conjunction with one another, the rudder shifts continously form 5 degrees port to 30 degrees starboard without stopping.
Action required: 705 - Other - as specified
Due 13 May 2006
Resolved 9 June 2006
Resolution: Received class report from DNV satisfying requirement.
Navigation › Collision/Grounding Avoidance › Radar
Issued 15 January 2005 Resolved
Vessels secondary radar was inoperable. Vessel was issued a Letter of deviation to enter the port of Savannah.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2005
Resolved 19 February 2005
Resolution: Received tech report from MacKay Marine attesting to proper repairs.
Navigation › Collision/Grounding Avoidance › Radar
Issued 9 August 2004 Resolved
Vessel has one radar inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2004
Resolution: Received tech report attesting to proper repairs.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 27 July 2004 Resolved
Gryo Compass Repeater - Unknown Cause/Condition (33CFR164.35(e))
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2004
Resolved 28 July 2004
Resolution: Received technician''s report attesting to satisfactory operation of gyrocompass and repeaters.
Pollution Prevention/Response › Prevention Equipment
Issued 13 February 2003 Resolved
Marine Sanitation Device does not have appropriate nameplate and approval placard. Must have proper placard posted prior to next U.S. port after sailing foreign. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 March 2003
Resolved 24 March 2003
Resolution: Marine inspector attended vessel and found the correct nameplate and approval placard affixed to the MSD.
Construction/Loadline › Hull
Issued 13 February 2003 Resolved
Shell plating iwo rudder post is wasted and holed. Class to inspect exterior and interior of void space associated with the damaged area. Class to make recommendations for permanent repairs and proposal to be accepted by COTP prior to departure. LEGACY COMPONENT DESC: Hull Plating
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 14 February 2003
Resolution: ADDRESSED BY CLASS.
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 13 February 2003 Resolved
AC condensor holed. Make permanent repairs to the satisfaction of class society.
Action required: 705 - Other - as specified
Due 13 March 2003
Resolved 14 February 2003
Resolution: ADDRESSED BY CLASS
Engineering › Sea-water System (primary cooling)
Issued 13 February 2003 Resolved
Aux condensor s/w cooling pipe wasted port side in way of main service generators. Make permanent repairs to the satisfaction of class. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 13 March 2003
Resolved 14 February 2003
Resolution: ADDRESSED BY CLASS
Lifesaving › Lifeboat
Issued 13 February 2003 Resolved
STBD lifeboat hole forward of door as marked. Repair to the satisfaction of class. LEGACY COMPONENT DESC: Hull
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 14 February 2003
Resolution: ADDRESSED BY CLASS
Lifesaving › Lifeboat
Issued 13 February 2003 Resolved
Stbd lifeboat hole in lower outer shell fwd on outer side. Repair to the satisfaction of class. (covered in duct tape) LEGACY COMPONENT DESC: Hull
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 14 February 2003
Resolution: ADDRESSED BY CLASS
Lifesaving › Launching Appliances
Issued 13 February 2003 Resolved
Davit launch system on STBD lifeboat not operating properly. Class surveyor to attest to the proper operation of system. LEGACY COMPONENT DESC: Davit
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 14 February 2003
Resolution: ADDRESSED BY CLASS
Lifesaving › Lifeboat
Issued 13 February 2003 Resolved
Grab line on outboard side of port lifeboat wasted. Repair to the satisfaction of class. LEGACY COMPONENT DESC: Handholds/Handrails
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 14 February 2003
Resolution: ADDRESSED BY CLASS
Lifesaving › Lifeboat
Issued 13 February 2003 Resolved
Light on portside lifeboat broken off, bucket covering. Repair to the satisfaction of class. LEGACY COMPONENT DESC: Lamp (inside)
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 14 February 2003
Resolution: ADDRESSED BY CLASS
Lifesaving
Issued 1 December 1999 Resolved
INSPECT ALL CREW LIFE JACKETS AND REPLACE ALL WATER LIGHT BATTERIES WHICH INDICATE AN EXPOSURE TO MOISTURE. ANY CRACKING/SWELLING/OTHER DEFORMITIES REQUIRES REPLACEMENT OF WATER ACTIVATED BATTERIES REGARDLESS OF EXPIRATION DATE ON THE BATTERY.
Condition: Unknown
Due 1 December 1999
Resolved 6 January 2000
Documentation
Issued 1 December 1999 Resolved
UPDATE IOPP CERTIFICATE TO REFLECT ALL TANKS BEING USED FOR WASTE OIL AND OILY WATER COLLECTION. ADDITIONALLY LIST EACH TANKS VOLUME AND LOCATION.
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Lifesaving
Issued 1 December 1999 Resolved
UPON NEXT VISIT OF CLASS, DETERMINE IF LIFEBOATS & LAUNCHING APPLIANCES AREREQUIRED TO MEET REG III/48. SPECIFICALLY DETERMINE IF REQUIRED TO MEET III/48.1.4., THAT THE LAUNCHING MECHANISM IS SUITABLY ARRAINGED SO THAT IT MAY BE ACTUATED FROM A POSITION WITHIN THE SURVIVAL CRAFT.
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Construction/Loadline
Issued 1 December 1999 Resolved
SERVICE/REPAIR AS NEEDED ALL WEATHER DECK VENT CLOSURES. EACH VENT COVER MUST ALLOW FOR SECURING IN A WATER TIGHT POSITION/CLOSURE.
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Fire Fighting
Issued 1 December 1999 Resolved
ADJUST/REPAIR AS NEEDED TO ALLOW FIRE SCREEN DOORS TO MACHINERY SPACES AND DOORS IN STAIR TOWER TO FULLY CLOSE AND LATCH.
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Lifesaving
Issued 1 December 1999 Resolved
REMOVE FLAMMABLE PAINTS AND SOLVENTS FROM THE MACHINERY SPACE OF THE BOILERUPTAKE/EXHAUST STACK. PROPERLY STOW ALL FLAMMABLE MATERIALS IN PAINT LKR.
Condition: Unknown
Due 1 December 1999
Resolved 6 January 2000
Lifesaving
Issued 1 December 1999 Resolved
SERVICE/REMOVE EXCESS PAINT & CORROSION FROM LIFEBOAT HATCH COVER HOLD OPENLATCH HARDWARE. (NOTE: DURING BOAT DRILL, HATCH COVERS WERE HELD OPEN BY CREW. FOR SAFETY REASONS DUE TO THE SIZE & WEIGHT OF COVERS, THE USE OF THEINSTALLED MECHANICAL HOLD OPEN DEVICES SHOULD ALWAYS BE REQUIRED).
Condition: Unknown
Due 1 December 1999
Resolved 6 January 2000
Lifesaving
Issued 1 December 1999 Resolved
REMOVE/CLEAN OIL FROM INSIDE STBD LIFEBOAT DECKS & PROPERLY SECURE LIFEBOATSTORES.
Condition: Unknown
Due 1 December 1999
Resolved 6 January 2000
Electrical
Issued 1 December 1999 Resolved
IDENTIFY AND MARK LIGHT FIXTURES WHICH ARE CONNECTED TO THE EMERGENCY LIGHTING CIRCUIT TO ALLOW TESTING AS REQUIRED BY II-1/43.7
Condition: Unknown
Due 1 December 1999
Resolved 6 January 2000
Lifesaving
Issued 28 November 1997 Resolved
VESSEL IS TO REPLACE THE BUOYANT LIFELINES ON THE PORT/STARBOARD LIFEBOATS WITHIN 30 DAYS. (SOLAS 74, CHAPTER III, REGULATION 41.7.3).
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Electrical
Issued 23 August 1995 Resolved
REPLACE LIGHT GLOBE IN FIXTURE OVER EMERGENCY FIRE PUMP. (SOLAS II-1/41 2.1).
Condition: Unknown
Due 23 August 1995
Resolved 23 August 1995
Fire Fighting
Issued 23 August 1995 Resolved
FILL EMERGENCY FIRE PUMP FUEL TANK (80% ON INSPECTION). (SOLAS II-2/4 3.3.2.4).
Condition: Unknown
Due 23 August 1995
Resolved 23 August 1995
Accommodation/Occupational Safety
Issued 23 August 1995 Resolved
HOSPITAL TOILET INOPERABLE. (ILO 147) CORRECT BY 23SEP95.
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Lifesaving
Issued 23 August 1995 Resolved
PORTSIDE LIFEBOAT HOISTING SYSTEM IS INOPERABLE. (SOLAS CHAP III REG.48 1.10). CORRECT PRIOR TO DEPARTURE FROM THE MISSISSIPPI RIVER OR BY 01SEP95.PROVIDE CLASS REPORT UPON COMPLETION OF REPAIRS PRIOR TO NOTIFICATION OF THE U.S. COAST GUARD--COTP NEW ORLEANS.
Condition: Unknown
Due 1 September 1995
Resolved 25 August 1995
Documentation
Issued 24 June 1992 Resolved
When asked by the boarding officer, the chief engineer could not provide any oil transfer procedures, even though he stated that they were onboard.
Condition: Unknown
Due 23 August 1995
Resolved 23 August 1995
Navigation
Issued 8 December 1987 Resolved
CHART NOS 18751 NOT CURRENTLY CORRECTED AS REQUIRED BY 33 CFR 164.33(A)(1) (II).
Condition: Unknown
Due 8 December 1987
Resolved 8 December 1987
Unknown
Issued 23 October 1986 Resolved
OWNER, MASTER, AGENT, OR P.I.C. OF A VESSEL ON A VOYAGE GREATER THAN 24 HRSFAILED TO GIVE 24 HOURS ADVANCED NOTICE OF ARRIVAL.
Condition: Unknown
Due 23 August 1995
Resolved 23 August 1995
Navigation
Issued 27 August 1986 Resolved
NOS CHART 18749 NOT CORRECTED UP TO DATE. NOS COAST PILOT VOL 7 NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 27 August 1986
Resolved 27 August 1986
Engineering
Issued 27 August 1986 Resolved
FUEL OIL DISCHARGE CONATINMENT WAS INADEQUATE.
Condition: Unknown
Due 27 August 1986
Resolved 27 August 1986
Engineering
Issued 27 August 1986 Resolved
NO PERSON-IN-CHARGE AT SITE OF OIL TRANSFER OPERATION.
Condition: Unknown
Due 27 August 1986
Resolved 27 August 1986
Engineering
Issued 27 August 1986 Resolved
FUEL OIL DISCHARGE CONTAINMENT WAS IMPROPER.
Condition: Unknown
Due 27 August 1986
Resolved 27 August 1986
Documentation
Issued 5 June 1986 Resolved
THE VSL'S IOPP CERTIFICATE IS EXPIRED AS OF 18MAR86
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Documentation
Issued 5 June 1986 Resolved
EACH COMPLETED PAGE NOT SIGNED BY THE MASTER
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Navigation
Issued 5 June 1986 Resolved
U.S. COAST PILOT #7 1985 DID NOT CONTAIN ANY CORRECTIONS FROM NOTICE TO MARINIERS 33 CFR 164.33(A)(2)(II)
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Navigation
Issued 5 June 1986 Resolved
MANUEVERING FACT SHEET MISSING: 1) TIME AND DISTANCE TO STOP AT 1/2 SPEED BALLAST CONDITION 2) R.P.M. VS SPEED
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.