MAURY USCG vessel records Sign in
← All vessels

GULFSTREAM

GULFSTREAM is a 1975 tank ship. The Coast Guard has recorded 21 inspections since 1984, most recently in December 1999, along with 56 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1984 to 1999. Most recent: inspection, 12 December 1999.

Built
1975
Last inspected
12 December 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7381544 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224706
Flag
LIBERIA
—
Maury page id
psix-224706

Inspections, by type

…with no type recorded15
…past their stated due date1
Years with a record 8 calendar years (1984–1999)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it21217 - Dead Weight, Ton
9392 - Regulatory (Subpart C or D), Net Ton
15114 - Convention (Subpart B), Net Ton
13660 - Regulatory (Subpart C or D), Gross Ton
13439 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

12 December 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 435444
21 January 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 424578
21 January 1999 Tank Vessel Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 789508
24 April 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 415419
17 November 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 699257
13 November 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 38966
6 November 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 409675
6 November 1997 Tank Vessel Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1119411
12 December 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 398463
20 July 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 393480
1 April 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 389600
5 November 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 384710
5 November 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1466402
4 November 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 49688
1 November 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 384402
20 May 1995 Tank Vessel Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1440932
28 May 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 946330
27 May 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 350906
1 April 1992 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 952754
16 June 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 323967
21 November 1984 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 299083

Deficiency record · 56

Engineering
Issued 12 December 1999 No resolution recorded
Correct all leaks on the stbd generator.
Condition: Unknown
Due 21 January 2000 — due date passed with no resolution recorded
Engineering
Issued 21 January 1999 Resolved
REPAIR EXCESSIVE LEAKS ON DOP
Condition: Unknown
Due 25 January 1999
Resolved 28 January 1999
Engineering
Issued 21 January 1999 Resolved
REPAIR LEAKING VALVES ON BOILER
Condition: Unknown
Due 25 January 1999
Resolved 26 January 1999
Fire Fighting
Issued 21 January 1999 Resolved
REPAIR LEAKING SUPPLY VALVE TO FIXED FF IN PURIFIER RM
Condition: Unknown
Due 25 January 1999
Resolved 26 January 1999
Accommodation/Occupational Safety
Issued 21 January 1999 Resolved
BOLT DOWN TOP ACCESS COVER ON MSD
Condition: Unknown
Due 25 January 1999
Resolved 26 January 1999
Fire Fighting
Issued 21 January 1999 Resolved
PLACE EXT BY MSD IAW FIRE PLAN.
Condition: Unknown
Due 25 January 1999
Resolved 26 January 1999
Accommodation/Occupational Safety
Issued 21 January 1999 Resolved
REPAIR SHIP'S H/W CIRC PUMP WHICH IS LEAKING EXCESSIVELY
Condition: Unknown
Due 25 January 1999
Resolved 26 January 1999
Engineering
Issued 21 January 1999 Resolved
REPAIR AIR LEAK FROM BOILER CASING.
Condition: Unknown
Due 25 January 1999
Resolved 26 January 1999
Lifesaving
Issued 21 January 1999 Resolved
REPLACE HAND-HELD FLAIRS IN BOTH LIFEBOATS
Condition: Unknown
Due 25 January 1999
Resolved 28 January 1999
Fire Fighting
Issued 21 January 1999 Resolved
REPAIR FROZEN SUPPLY VALVES TO INT SHORE CONN
Condition: Unknown
Due 25 January 1999
Resolved 28 January 1999
Lifesaving
Issued 21 January 1999 Resolved
REMOVE CORROSIVE MATERIALS FROM CARGO PUMP ROOM
Condition: Unknown
Due 25 January 1999
Resolved 28 January 1999
Fire Fighting
Issued 21 January 1999 Resolved
TIGHTEN EMERGENCY F/P BELT COVER
Condition: Unknown
Due 25 January 1999
Resolved 26 January 1999
Lifesaving
Issued 21 January 1999 Resolved
CLEAN SLIPPERY DK IN EMRGENCY F/P ROOM
Condition: Unknown
Due 25 January 1999
Resolved 26 January 1999
Fire Fighting
Issued 21 January 1999 Resolved
PLACE NEW LATCH ON FIRE HOSE BOX IN E/R
Condition: Unknown
Due 25 January 1999
Resolved 26 January 1999
Fire Fighting
Issued 21 January 1999 Resolved
REPLACE F/P VOLUTE GASKET
Condition: Unknown
Due 25 January 1999
Resolved 26 January 1999
Lifesaving
Issued 21 January 1999 Resolved
REPAIR LEAKING CARGO WASH PUMP
Condition: Unknown
Due 25 January 1999
Resolved 26 January 1999
Electrical
Issued 21 January 1999 Resolved
REPAIR EXCESSIVE LEAKS ON #2 SSDG
Condition: Unknown
Due 25 January 1999
Resolved 28 January 1999
Lifesaving
Issued 21 January 1999 Resolved
PROVE PROPER OPERATION OF P & S L/B DAVIT LIMIT SWITCHES AND PROPER RECOVERY OF THE BOATS
Condition: Unknown
Due 22 January 1999
Resolved 28 January 1999
Documentation
Issued 21 January 1999 Resolved
CLAS TO VERIFY THAT THE SMS IS IN COMPLIANCE WITH ISM CODE
Condition: Unknown
Due 22 January 1999
Resolved 28 January 1999
Lifesaving
Issued 21 January 1999 Resolved
MAKE PERMANENT REPAIRS TO ENGINE ROOM CONTROL ROOM DOOR TO MAKE IT SELF CLOSING
Condition: Unknown
Due 25 January 1999
Resolved 28 January 1999
Engineering
Issued 21 January 1999 Resolved
CLASS TO ATTEST TO PROPER OPERATION OF MDE L/O SERVO MOTOR
Condition: Unknown
Due 25 January 1999
Resolved 28 January 1999
Accommodation/Occupational Safety
Issued 21 January 1999 Resolved
MAKE PERMANENT REPAIRS TO SEWAGE PIPES TO THE MSD
Condition: Unknown
Due 25 January 1999
Resolved 28 January 1999
Lifesaving
Issued 21 January 1999 Resolved
CLEAN ALL WALKWAY AREAS AND BILGES
Condition: Unknown
Due 25 January 1999
Resolved 28 January 1999
Lifesaving
Issued 21 January 1999 Resolved
PROVIDE PORT SEAT IN PORT L/B
Condition: Unknown
Due 22 January 1999
Resolved 28 January 1999
Lifesaving
Issued 21 January 1999 Resolved
PROVIDE 2 NEW EMBARKATION LADDERS
Condition: Unknown
Due 22 January 1999
Resolved 28 January 1999
Fire Fighting
Issued 21 January 1999 Resolved
CONDUCT PROPER FIRE DRILL
Condition: Unknown
Due 25 January 1999
Resolved 28 January 1999
Deck/Cargo
Issued 21 January 1999 Resolved
REPAIR STEAM LEAKS ON CARGO PUMPS
Condition: Unknown
Due 25 January 1999
Resolved 28 January 1999
Lifesaving
Issued 21 January 1999 Resolved
PROVE PROPER OPERATION OF P & S L/B DAVIT BRAKES
Condition: Unknown
Due 22 January 1999
Resolved 28 January 1999
Accommodation/Occupational Safety
Issued 21 January 1999 Resolved
MAKE PERMANENT REPAIRS TO HOLED MSD
Condition: Unknown
Due 12 December 1999
Resolved 12 December 1999
Engineering
Issued 21 January 1999 Resolved
REPLACE HOLED F/O STEAM HEATING PIPE IN WAY OF BOTH GENERATORS
Condition: Unknown
Due 12 December 1999
Resolved 12 December 1999
Lifesaving
Issued 24 April 1998 Resolved
BOAT DAVIT SHEVES WASTED ON BOTH LIFEBOATS.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Fire Fighting
Issued 24 April 1998 Resolved
CREW UNABLE TO PERFORM SATISFACTORY FIRE DRILL.
Condition: Unknown
Due 26 April 1998
Resolved 30 April 1998
Fire Fighting
Issued 24 April 1998 Resolved
FIREMANS OUTFIT UNSERVICABLE.
Condition: Unknown
Due 26 April 1998
Resolved 30 April 1998
Lifesaving
Issued 24 April 1998 Resolved
REFLECTIVE TAPE ON LIFEBOATS PAINTED OVER.
Condition: Unknown
Due 26 April 1998
Resolved 30 April 1998
Fire Fighting
Issued 6 November 1997 Resolved
REPAIR HOLED FIREMAIN & TANK PIPING IN WAY OF CARGO TANKS 5&7 CENTER._x001C_ SOLAS 74 AMENDED REG II-2/21_x001C_ _x001C_
Condition: Unknown
Due 7 November 1997
Resolved 7 November 1997
Deck/Cargo
Issued 6 November 1997 Resolved
REPAIR CARGO PUMP EMERGENCY SHUTDOWNS, TEST; OPERATIONALLY UNSATISFACTORY._x001C__x001C_ 33CFR 155.780
Condition: Unknown
Due 7 November 1997
Resolved 7 November 1997
Accommodation/Occupational Safety
Issued 6 November 1997 Resolved
REPLACE MISSING SAFETY/OPERATING INSTRUCTIONS FOR MARINE SANITATION DEVICE._x001C_ 33CFR 159.59
Condition: Unknown
Due 7 December 1997
Resolved 7 November 1997
Deck/Cargo
Issued 20 July 1996 Resolved
oil discharge monitor inopertive
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Electrical
Issued 20 July 1996 Resolved
#1 starboard generator inoperative_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Construction/Loadline
Issued 1 November 1995 Resolved
REMOVE LOCKS ON EXTERIOR DOORS IN SUPERSTRUCTURE_x001C_ _x001C_ _x001C_ SOLAS 60 II/68
Condition: Unknown
Due 2 November 1995
Resolved 17 November 1995
Fire Fighting
Issued 1 November 1995 Resolved
DEMONSTRATE PROPER OPERATION OF EMERGENCY FIRE PUMP. _x001C_ PROVIDE CLASS SURVEYOR'S REPORT TO U.S. COAST GUARD._x001C_ _x001C_ SOLAS 60 REGULATION 56
Condition: Unknown
Due 2 November 1995
Resolved 15 November 1995
Construction/Loadline
Issued 1 November 1995 Resolved
CLEAN MACHINERY SPACE (ENGINE ROOM) OF EXCESS OIL IN BILGES.
Condition: Unknown
Due 2 November 1995
Resolved 17 November 1995
Deck/Cargo
Issued 1 November 1995 Resolved
CLEAN CARGO PUMP OF PALM OIL IN THE BILGES
Condition: Unknown
Due 2 November 1995
Resolved 17 November 1995
Construction/Loadline
Issued 1 November 1995 Resolved
PROPERLY SEAL WATERTIGHT BULKHEAD BETWEEN CARGO PUMP ROOM AND ENGINE ROOM_x001C_ WHERE #3 CARGO PUMP SHAFT PENTRATES BULKHEAD.
Condition: Unknown
Due 2 November 1995
Resolved 17 November 1995
Deck/Cargo
Issued 20 May 1995 Resolved
Cargo pump shaft packing loose, disturbed during repairs to #3 steam turbine.
Condition: Unknown
Due 20 May 1996
Resolved 2 November 1995
Deck/Cargo
Issued 20 May 1995 Resolved
Steam turbines for #1 and #3 cargo pumps inoperative, awaiting parts/repair.
Condition: Unknown
Due 20 May 1996
Resolved 2 November 1995
Navigation
Issued 20 May 1995 Resolved
NO U.S. Chart 12274, 12277 OR FOREIGN EQUIVALENT ON BOARD.
Condition: Unknown
Due 20 May 1995
Resolved 22 May 1995
Accommodation/Occupational Safety
Issued 28 May 1992 Resolved
ENSURE MAIN DECK INGRESS AND EGRESS OF SUPERSTRUCTURE IN ACCORDANCE WITH SOLAS CHAPTER II-2 REGULATION 28 PRIOR TO 1DEC92.
Condition: Unknown
Due 28 May 1992
Resolved 28 May 1992
Documentation
Issued 28 May 1992 Resolved
PROVIDE PROOF OF CLASSIFICATION SOCIETY LOADLINE SURVEY. LOADLINE MARKINGS_x001C_ARE BY ABS AND CERTIFICATE WAS ISSUED BY DET NORSKE VERITAS. REQUIREMENT MUST BE MET PRIOR TO LEAVING PORT OF NEW YORK._x001C_ _x001C_
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Construction/Loadline
Issued 1 April 1992 Resolved
Reinstall main cargo deck piping guards at the following locations: portside mid-deck, port side forward, starboard side forward, starboard side mid deck._x001C_ _x001C_
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Deck/Cargo
Issued 1 April 1992 Resolved
Provide oily water seperator with an approved oil interface monitor meetingthe requirements of regulation 16(7) in that the monitor is equipped with a15 parts per million audible alarm._x001C_ _x001C_
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Construction/Loadline
Issued 1 April 1992 Resolved
Repack steering gear rudder post to prevent excessive leakage of water intoafter steering compartment. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Navigation
Issued 1 April 1992 Resolved
Prior to return to next U.S. port, provide the emergency steering station with a gyro repeater as per SOLAS chapter V, regulation 12(f)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Construction/Loadline
Issued 1 April 1992 Resolved
Remove all watertight door "slide bar locks" from all egress doors exiting living spaces._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Construction/Loadline
Issued 1 April 1992 Resolved
BOTH MAIN DECK FORWARD FACING WATERTIGHT DOORS TO BE LOCKED CLOSED DURING CARGO OPERATIONS. THESE DOORS ARE TO BE PERMANENTLY CLOSED OR REMOVED PRIOR TO RETURN TO NEXT U.S. PORT._x001C_ _x001C_
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Deck/Cargo
Issued 1 April 1992 Resolved
Complete permanent repairs to number 3 cargo pump stripping line prior to utilizing for cargo operations. Repairs to be hydrostatically tested to 1.25 times MAWP and logged for review in vessel's official log._x001C_ _x001C_
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.