Records from 1984 to 1994. Most recent: inspection, 23 November 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 37
23 November 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 455670
23 November 1994
Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1446146
5 November 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 496436
1 November 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 863621
6 December 1993
Tank Vessel Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1160505
21 August 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 491787
14 August 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 446681
5 January 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 828662
1 January 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 355409
1 January 1993
Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1141494
29 May 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 351014
26 November 1991
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 939337
3 October 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 456173
28 November 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 340468
28 November 1990
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1218384
30 June 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 337949
29 March 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 924252
1 November 1989
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1233039
9 March 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 465397
9 March 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 890928
16 November 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 468887
16 April 1988
Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1030720
16 April 1988
Damage Survey
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1033444
15 April 1988
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 482399
13 February 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 443566
28 July 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 317583
7 April 1987
Certificate of Compliance
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314051
25 January 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 466450
18 May 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 308920
18 May 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 997529
27 February 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 307266
25 February 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 307194
25 February 1986
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 991430
24 November 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 453276
2 April 1985
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 301122
8 March 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 300721
19 September 1984
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 469283
Lifesaving
Issued 23 November 1994
Resolved
PROVIDE (61)SIXTY ONE REPLACEMENT LIFEBOAT RATIONS.
Condition: Unknown
Due 25 November 1994
Resolved 29 November 1994
Deck/Cargo
Issued 6 December 1993
Resolved
RENEW THE DRAIN VALVE FORWARD OF THE DECK WATER SEAL.
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Deck/Cargo
Issued 6 December 1993
Resolved
REMOVE TEMPORARY CONCRETE PATCH AND RENEW HEATING PIPING FOR NO. 2 CENTER CARGO TANK; RENEW MAIN DECK PLATING IF NECESSARY AFTER REMOVAL OF PATCH.
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Deck/Cargo
Issued 6 December 1993
Resolved
PROVE PROPER OPERATION OF THE E.O.S. IGS STRIP RECORDER (O2 CONTENT).
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Engineering
Issued 6 December 1993
Resolved
RENEW THE NO. 1 AND 2 BOILER FIRE BOX PEEP GLASS.
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Engineering
Issued 6 December 1993
Resolved
MAKE NO 1 BOILER CASING TIGHT.
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Engineering
Issued 6 December 1993
Resolved
PROPERLY CONNECT THE NO. 1 BOILER SAFETY VALVES HAND RELIEVING GEAR.
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Deck/Cargo
Issued 6 December 1993
Resolved
REMOVE TEMPORARY REPAIR PATCHES AND RENEW HOLED IGS CONDENSATE RETURN.
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Engineering
Issued 6 December 1993
Resolved
REMOVE TEMPORARY PATCH AND PERMANENTLY REPAIR HOLED SECTION OF DECK STEAM LINE.
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Fire Fighting
Issued 6 December 1993
Resolved
REMOVE TEMPORARY PATCH AND PERMANENTLY REPAIR HOLED SECTION OF MAIN DECK FIREMAIN PIPING.
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Deck/Cargo
Issued 6 December 1993
Resolved
RENEW AFT SPRING WINCH CASING HEAD.
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Construction/Loadline
Issued 1 January 1993
Resolved
PRIOR TO DEPARTING PORT OF BOSTON MAKE PERMANENT REPAIRS TO FRACTURE AT FRAME #61 IN #5 STARBOARD SBT AND CRACKS IN FRAME #62 IN #5 STARBOARD AND #5 PORT SBT'S. ALL FRACTURES ARE LOCATED ON THE 6TH LONGITUDINAL UP FROM THE TURN OF THE BILGE._x001C_
Condition: Unknown
Due 1 January 1993
Resolved 1 January 1993
Deck/Cargo
Issued 27 February 1986
Resolved
46CFR32.53-5 VESSSEL HAD ONBOARD 355,718 BBLS ECUADORIAN CRUDE OIL (A FLAMMABLE CARGO) AND CARGO TANKS WERE NOT PROPERLY INERTED.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Deck/Cargo
Issued 25 February 1986
Resolved
46CFR32.53-5 VESSEL HAS ONBOARD 355,718 BBLS ECUADORIAN CRUDE OIL (A FLAMMABLE CARGO) AND CARGO TANKS WERE NOT PROPERLY INERTED.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Engineering
Issued 25 February 1986
Resolved
33CFR155.320(A)(2) VESSEL HAS NO FIXED CONTAINER OR ENCLOSED DECK AREA UNDER OR AROUND THE BULK LUBRICATING OIL FILL TUBE.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Engineering
Issued 25 February 1986
Resolved
PROVIDE FIXED SPILL CONTAINMENT FOR THE LUBE OIL FILL PIPE TO COMPLY WITH 33 CFR 155.320(A)(2).
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Fire Fighting
Issued 25 February 1986
Resolved
MAKE PERMANENT REPAIRS TO ALL DECK FOAM MONITORS.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Fire Fighting
Issued 25 February 1986
Resolved
PROVIDE A FIRE FIGHTING SYSTEM FOR THE FORECASTLE PAINT LOCKER WHICH WILL COMPLY WITH 46 CFR 34.05-5.
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Fire Fighting
Issued 25 February 1986
Resolved
MAKE PERMANENT REPAIRS TO METAL GRATING AROUND AFTER MOST DECK FOAM MONITOR
Condition: Unknown
Due 25 February 1986
Resolved 25 February 1986
Deck/Cargo
Issued 8 March 1985
Resolved
VESSEL HAS P/V VALVES ON #6 PORT AND #7 PORT CARGO TANKS THAT LEAK EXCESSIVELY.
Condition: Unknown
Due 8 March 1985
Resolved 8 March 1985
Documentation
Issued 8 March 1985
Resolved
VESSEL DID NOT HAVE A FIRE CONTROL PLAN POSTED OUTSIDE THE DECK HOUSE IN A WATER TIGHT ENCLOSURE AS REQ BY SOLAS 74 REG 20.2
Condition: Unknown
Due 8 March 1985
Resolved 8 March 1985
Deck/Cargo
Issued 8 March 1985
Resolved
VESSEL ARRIVED AT THE DOCK AT APPROX 1200 HOURS.AT 1230 VESSEL WAS OBSERVEDTO HAVE NO INERT GAS BLANKET ON CARGO TANKS AS REQ BY 33 CFR 32.53-5.
Condition: Unknown
Due 8 March 1985
Resolved 8 March 1985
Deck/Cargo
Issued 8 March 1985
Resolved
VESSEL HAD NUMEROUS FLAME SCREENS TORN,WASTED OR MISSING ON BUNKERING TANKSAND SEVERAL CARGO TANK VENTS.
Condition: Unknown
Due 8 March 1985
Resolved 8 March 1985