Professional
The full record for this vessel
Behind this panel: 4 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 4
18 July 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5944610
21 June 2016
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5914029
21 June 2016
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5923380
7 June 2016
ISPS II Exam · COC-TVE Renew
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5899761
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 21 June 2016
Resolved
01-Cargo Transfer-Cargo tranfer hose (metal) does not state "OIL SERVICE" or Product being transfered and does not state "MAWP". Also hose is marked with test pressure which is incorrect. Remove current tag and affix proper hose markings.-33CFR155.800 33CFR157.500
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 18 July 2016
Resolution: Hoses have been properly marked
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 June 2016
Resolved
Deck rail broke starboard aft on safe access to the bow. Deck grating has a hole and one section has a section of deck grating not properly secured.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2016
Resolved 21 June 2016
Resolution: Safe access to the bow was restored.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 7 June 2016
Resolved
Numerous Class A-60 fire doors have been modified and therefore have been compromised and are not installed per the approved Fire Control plan.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 June 2016
Resolved 21 June 2016
Resolution: Fire boundaries were corrected
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 7 June 2016
Resolved
Dead end wiring in cargo pump room. Ends to be properly terminated or removed. Numerous sections of wiring cut and left with exposed wiring.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2016
Resolved 21 June 2016
Resolution: Old wiring was removed
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 7 June 2016
Resolved
Electrical lighting fixtures were all loose. Bulbs broken exposing element. Gasket material seats were compromied. Identify and renew to ensure explosive atmosphere does not come into contact with flammable vapors.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2016
Resolved 21 June 2016
Resolution: Lighting was renewed
Communications › Alarms/Indicators › General Alarm
Issued 7 June 2016
Resolved
General alarm light in the cargo pump room has been inoperable for 4 years.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2016
Resolved 21 June 2016
Resolution: General alarm light has been repaired
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 7 June 2016
Resolved
Transfer hoses not tested properly. Test pressure of 152 psi marked on hose. Vessel to re-test and properly mark each of the rubber transfer hoses with MAWP and "Oil Servcie Only"
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2016
Resolved 21 June 2016
Resolution: Rubber hose was taken out of service