Records from 1985 to 1998. Most recent: inspection, 17 August 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 25
17 August 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 419398
18 June 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 417221
23 May 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 391782
9 July 1994
Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1354824
19 August 1992
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 953498
11 August 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 687680
7 August 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 164477
7 August 1992
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1269735
6 August 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 537127
22 May 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 350995
22 May 1992
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1265600
12 August 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 345172
24 April 1991
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1000070
21 April 1991
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 919358
19 January 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 504897
14 September 1989
Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1208214
10 September 1988
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 495075
10 September 1988
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1353080
6 December 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 480236
30 July 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 317550
30 July 1987
MARPOL Annex II Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1334505
3 April 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 484993
15 August 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 310788
19 May 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 308919
11 March 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 300638
Navigation
Issued 17 August 1998
No resolution recorded
Repair echo depth sounder recorder as per 33 C.F.R 164.35(i).
Condition: Unknown
Due 17 September 1998 — due date passed with no resolution recorded
Navigation
Issued 18 June 1998
Resolved
INOPERABLE ECHO DEPTH SOUNDER.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Deck/Cargo
Issued 23 May 1996
Resolved
DO NOT OPERATE #3 CARGO PUMP DURING CARGO OPERATIONS DUE TO LEAK IN BILGE_x001C_ AT PUMP SHAFT LOCATION. PROVIDE CLASS SURVEY REPORT TO [name withheld] CARGO OPERATIONS AT TEXAS CITY.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Deck/Cargo
Issued 21 April 1991
Resolved
MAKE REPAIRS TO I.G.S. HIGH TEMP INDICATOR SWITCH AND PROPER OPERATION TO SATISFACTION OF COGNIZANT O.C.M.I.
Condition: Unknown
Due 21 April 1991
Resolved 21 April 1991
Construction/Loadline
Issued 21 April 1991
Resolved
PROVIDE FOR C.G. INSPECTION, DOCUMENTATION OF REPAIRS COMPLETED IN WAY OF #4 PORT CARGO TANK.
Condition: Unknown
Due 21 April 1991
Resolved 21 April 1991
Documentation
Issued 10 September 1988
Resolved
VESSEL MUST HAVE ON BOARD PRIOR TO RETURNING TO US WATERS A COPY OF 46CFR PARTS 1-40
Condition: Unknown
Due 10 September 1988
Resolved 10 September 1988
Documentation
Issued 10 September 1988
Resolved
VESSEL MUST HAVE ON BOARD PRIOR TO RETURNING TO US WATERS A COPY OF 33CFR PARTS 1-199
Condition: Unknown
Due 10 September 1988
Resolved 10 September 1988
Engineering
Issued 30 July 1987
Resolved
PROVIDE STANDARD DISCHARGE CONNECTION ON BOARD IN ACCORDANCE WITH 33CFR155.430.
Condition: Unknown
Due 30 July 1987
Resolved 30 July 1987
Navigation
Issued 19 May 1986
Resolved
PRIOR TO DEPARTURE PORT OF PHILADELPHIA, MUST MAKE PERMANENT REPAIRS TO 3CM RADAR. THE U.S. COAST GUARD MUST BE NOTIFIED OF THE REPAIRS. 33 CFR 164.37(A)
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986
Deck/Cargo
Issued 19 May 1986
Resolved
PRIOR TO NEXT U.S. PORT, MUST MAKE PERMANENT REPAIRS TO MECHANICAL SEAL ON FOWARD INERT GAS BLOWER. 32.53-45
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986