Records from 1984 to 2001. Most recent: inspection, 5 September 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
5 September 2001
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1071475
25 August 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 292869
8 August 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 292553
25 February 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 412776
22 August 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 394411
25 September 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 382631
12 December 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 373576
12 December 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1151660
4 February 1994
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 364396
10 March 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 450687
29 August 1991
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 345513
2 August 1990
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 338567
24 July 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 331617
19 June 1988
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 324104
31 August 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 318200
19 December 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 487084
12 December 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 313193
22 April 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 308233
16 September 1985
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 304248
9 August 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 536802
16 March 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 300648
29 May 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 296479
Accommodation/Occupational Safety
Issued 8 August 2001
Resolved
SEWAGE PIPE HOLED, PATCHED, AND LEAKING IN TWO PLACES BY #1 GENERATOR._x001C_ (33 CFR 159.7). REPAIR PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001
Engineering
Issued 8 August 2001
Resolved
#1, #3, AND #4 FUEL INJECTORS LEAKING AT BASE ON #1 GENERATOR, AND #1 AND #3 FUEL INJECTORS ON #3 GENERATOR. (SOLAS 74A REG. I/11). REPAIR TO SATSFACTION OF CLASS.
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001
Accommodation/Occupational Safety
Issued 25 February 1998
Resolved
PROVIDE FOR EXTERMINATION OF INSECTS IN GALLEY, DRY STORES, AND REEFER SPACES._x001C_ ILO 147
Condition: Unknown
Due 8 August 2001
Resolved 8 August 2001
Accommodation/Occupational Safety
Issued 25 February 1998
Resolved
CLEAN OR REPLACE FILTERS OVER GALLEY STOVE AND ENSURE EXCESSIVE GREASE FROMSCREENS IS REMOVED._x001C_ ILO 147
Condition: Unknown
Due 8 August 2001
Resolved 8 August 2001
Engineering
Issued 25 February 1998
Resolved
REPLACE WASTED/MISSING FLAME SCREENS WITH APPROPRIATE MESH ON ALL FUEL OIL VENTS
Condition: Unknown
Due 8 August 2001
Resolved 8 August 2001
Navigation
Issued 4 February 1994
Resolved
VESSEL'S ANTI COLLISION RADAR WAS FOUND NOT TO BE INSTALLED PROPERLY, ACCORDING TO 33CFR164.38 APPENDIX B PARAGRAPH 2, INPUT FROM THE SPEEDLOG COULD NOT BE AUTOMATICALLY PLACED INTO THE ARPA.
Condition: Unknown
Due 21 December 1994
Resolved 21 December 1994
Navigation
Issued 22 April 1986
Resolved
A VIO OF 33 CFR 164.30 IN THAT A CURRENTLY CORRECTED COAST GUARD LIGHT LISTVOL 1 OR ITS FOREIGN EQUIV AS REQ BY 33 CFR 164.33(A)(2)(II) WAS NOT O/B. THE VSL HAD O/B COAST GUARD LIGHT LIST VOL 1 DTD 1985 WITH NO CORRECTIONS.
Condition: Unknown
Due 22 April 1986
Resolved 22 April 1986
Navigation
Issued 22 April 1986
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE CURRENT MAGNETIC COMPASS DEVIATION TABLEWAS NOT O/B.
Condition: Unknown
Due 12 December 1986
Resolved 22 April 1986
Navigation
Issued 22 April 1986
Resolved
A VIO OF 33 CFR 164.30 IN THAT A COMPLETE SET OF CURRENTLY CORRECTED U.S. CHARTS OR THEIR FOREIGN EQUIV OF THE AREA TRANSITED, AS REQ BY 33 CFR 164.33(A)(1)(II) WERE NOT O/B. THE VSL HAD O/B CHARTS #12222 DTD 14DEC85 CORRECTED TO 36/85 AND #12245 DTD 30JUN85 CORRECTED TO 35/85.
Condition: Unknown
Due 22 April 1986
Resolved 22 April 1986
Navigation
Issued 22 April 1986
Resolved
A VIO OF 33 CFR 164.30 IN THAT A CURRENTLY CORRECTED U.S. COAST PILOT VOL 3OR ITS FOREIGN EQUIV AS REQ BY 33 CFR 164.33(A)(2)(I) WAS NOT O/B. THE VSL HAD O/B U.S. COAST PILOT VOL 3 DTD 1985 WITH NO CORRECTIONS.
Condition: Unknown
Due 22 April 1986
Resolved 22 April 1986