Records from 1985 to 1990. Most recent: inspection, 12 February 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
12 February 1990
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 910915
4 December 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 334062
4 December 1989
Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 906970
26 July 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 331661
28 June 1989
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 470460
5 November 1988
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 326657
5 November 1988
Certificate of Compliance
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 891238
21 January 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 320848
4 December 1987
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 531836
4 December 1987
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1000953
4 June 1987
Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1031765
3 June 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 316507
6 February 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 306925
6 February 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1305903
6 September 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 442214
13 February 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 463212
13 February 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 978799
Engineering
Issued 4 December 1989
Resolved
33 CFR 155.370(A)(2) THE VESSEL'S 15 PPM OILY-WATER SEPARATING EQUIP- MENT FOR THE PROCESSING OF OILY BILGE SLOPS OR OILY FUEL OIL TANK BALLAST WAS INOPERATIVE.
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Accommodation/Occupational Safety
Issued 4 December 1989
Resolved
33 CFR 159.7(A) THE VESSEL WAS NOT EQUIPPED WITH AN OPERABLE TYPEI, II, OR III MARINE SANITATION DEVICE. (I.E.: THE VESSEL'S TYPE II MSD WASINOPERABLE).
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Deck/Cargo
Issued 4 December 1989
Resolved
STEAM LINE TO CRANE LEAKING. MAKE REPAIRS PRIOR TO RETURN TO U. S. PORT.
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Accommodation/Occupational Safety
Issued 4 December 1989
Resolved
BOTH MARINE SANITATION DEVICES INOPERATIVE. EFFECT TEMPORARY MEASURES IMMEDIATELY TO SECURE OVERBOARD SEWERAGE DISCHARGE. PROVIDE PERMANENT REPAIRS TO MSD'S PRIOR TO RETURNING TO THE PORT OF BOSTON.
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Engineering
Issued 4 December 1989
Resolved
INOPERATIVE OILY WATER SEPARATOR. PROVIDE PERMANENT REPAIRS PRIOR TO DEPARTING THE PORT OF BOSTON.
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Fire Fighting
Issued 4 December 1989
Resolved
EMERGENCY FIRE PUMP UNRELIABLE. CONDUCT SATISFACTORY OPERATIONAL TEST PRIOR TO CONDUCTING CARGO OPERATIONS.
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Electrical
Issued 4 December 1989
Resolved
INOPERATIVE EMERGENCY GENERATOR. CONDUCT SATISFACTORY OPERATIONAL TEST PRIOR TO CARGO OPERATIONS.
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Engineering
Issued 4 December 1989
Resolved
LEAKING MAIN CONDENSER FOR STEAM DRIVEN CARGO PUMPS. EFFECT REPAIRS AS DIRECTED BY THE SURVEYOR REPRESENTING THE VESSEL'S FLAG ADMINISTRATION. TEMPORARY REPAIRS ARE TO BE CONDUCTED PRIOR TO DEPARTURE; PERMANENT REPAIRSPRIOR RETURN PORT OF BOSTON.
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Accommodation/Occupational Safety
Issued 5 November 1988
Resolved
PROVIDE MANUFACTURES MANUAL AND MAKE MARINE SANITATION DEVICE OPERATIONAL IN A TYPE II MODE.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Accommodation/Occupational Safety
Issued 5 November 1988
Resolved
MAKE PERMANENT REPAIR TO MAINDICK CATWALK SUPPORT COLUMNS INWAY OF BROKEN WELDS TO MAINDECK.
Condition: Unknown
Due 5 December 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 5 November 1988
Resolved
MAKE PERMANT REPAIR IN WAY OF TEMPORARY PATCH ON MACHINERY SPACE FIRE MAIN.
Condition: Unknown
Due 5 November 1988
Resolved 5 November 1988
Navigation
Issued 3 June 1987
Resolved
SATELLITE NAVIGATION RECEIVER NOT WORKING.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Unknown
Issued 3 June 1987
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987