Records from 1986 to 1995. Most recent: inspection, 3 January 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
3 January 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 373773
11 July 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 700512
4 July 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 26023
4 July 1994
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1171886
13 June 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 463088
28 January 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165474
3 January 1994
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1164824
12 December 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1160646
26 November 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1157967
24 November 1993
Certificate of Compliance · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 847735
17 June 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 448102
11 April 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 507161
14 February 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 185483
9 November 1992
MARPOL Annex II Examination · Certificate of Compliance
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1132807
24 October 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 524250
5 August 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 524121
21 November 1991
Certificate of Compliance
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1250138
22 May 1991
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 485726
7 February 1991
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 537642
20 August 1990
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1221218
28 March 1990
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 437037
11 August 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 331835
11 August 1989
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1346193
14 July 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 324506
14 July 1988
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340451
9 September 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 311377
9 September 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1311033
Engineering
Issued 4 July 1994
Resolved
PUMP OUT CONTENTS OF STARBOARD FUEL OIL DEEP TANK. MAKE PERMANENT REPAIRS TO INSET CRACK OR KEEP TANK EMPTY BEFORE RETURNING TO US.
Condition: Unknown
Due 20 July 1994
Resolved 20 July 1994
Fire Fighting
Issued 24 November 1993
Resolved
REPAIR SEALS ON EMERGENCY FIRE PUMP TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 24 November 1993
Resolved 24 November 1993
Fire Fighting
Issued 24 November 1993
Resolved
REPLACE MISSING C02 NOZZLE FOR FIXED C02 FIRE FIGHTING PIPING IN WAY OF LOWER LEVEL, PUMP ROOM AFT. PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 24 November 1993
Resolved 24 November 1993
Navigation
Issued 24 November 1993
Resolved
PROVE PROPER OPERATION OF ARPA PRIOR TO DEPARTING PORT OF NEW YORK TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR OR CLASS SOCIETY SURVEYOR. EVIDENCE OF COMPLIANCE MAY BE PROVIDED BY TELE-FAX STATEMENT FROM CLASS SOCIETY SURVEYOR (DNV).
Condition: Unknown
Due 22 December 1993
Resolved 22 December 1993
Documentation
Issued 24 November 1993
Resolved
PROVIDE SAFETY EQUIPMENT CERTIFICATE AND RADIO TELEGRAPHY CERTIFICATE PRIORTO DEPARTING PORT OF NEW YORK. REQUIREMENT MAY BE SATISFIED BY TELE-FAX FROM CLASS SOCIETY SURVEYOR (DNV).
Condition: Unknown
Due 22 December 1993
Resolved 22 December 1993
Fire Fighting
Issued 9 November 1992
Resolved
REPLACE WASTED FIREMAIN PIPING BETWEEN FIRE MONITOR #2 FROM FORWARD AND THELONGITUDINAL FIREMAIN PIPING, NEAR ELBOW. TO BE COMPLETED PRIOR TO ENTERINGNEXT U.S. PORT.
Condition: Unknown
Due 9 November 1992
Resolved 9 November 1992
Deck/Cargo
Issued 9 November 1992
Resolved
REPAIR LEAK IN DECK STEAM LINE STARBOARD SIDE BELOW WATER WASHDOWN LINE, JUST FORWARD OF FOAM MONITOR #3 FROM FORWARD. TO BE COMPLETED PRIOR TO ENTERING NEXT U.S. PORT.
Condition: Unknown
Due 9 November 1992
Resolved 9 November 1992
Navigation
Issued 11 August 1989
Resolved
33CFR164.11(R) VESSEL ENTERED THE PORT OF CORPUS CHRISTI WITHOUT A PROPERLYOPERATING PRIMARY RADAR ACCORDING TO 33CFR164.35(A). VESSEL WAS ISSUED A LETTER OF DEVIATION TO ENTER THIS PORT WITHOUT AN OPERATIONAL PRIMARY RADAR
Condition: Unknown
Due 11 August 1989
Resolved 11 August 1989
Navigation
Issued 14 July 1988
Resolved
VESSEL HAD A 1986 EDITION OF THE LIGHT LIST ON BOARD NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Navigation
Issued 14 July 1988
Resolved
VESSEL DID NOT HAVE A TIDAL CURRENT TABLE ON BOARD.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Documentation
Issued 14 July 1988
Resolved
VESSEL'S OIL TRANSFER PROCEDURES WERE NOT IN THE ORDER PRESCRIBED BY 33 CFR155.750, NOR WAS A CROSS REFERENCE INDEX PAGE USED.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Navigation
Issued 14 July 1988
Resolved
VESSEL DID NOT HAVE A TIDE TABLE ON BOARD.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Navigation
Issued 14 July 1988
Resolved
VESSEL HAD A 1986 EDITION OF THE COAST PILOT ON BOARD NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Navigation
Issued 14 July 1988
Resolved
HARTS 12326 (ED.27), 12327 (ED.81), 12331 (ED.28), 12333 (ED.26) AND 12334 (ED.57) NOT CORRECTED UP TO DATE THROUGH THE LATEST NOTICE TO MARINERS.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992