MAURY USCG vessel records Sign in
← All vessels

SEA JEWEL

SEA JEWEL is a 1978 tank ship. The Coast Guard has recorded 21 inspections since 1985, most recently in August 2001, along with 29 deficiencies — 3 with no resolution recorded —.

Records from 1985 to 2001. Most recent: inspection, 31 August 2001.

Built
1978
Last inspected
31 August 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7383449 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224745
Flag
ITALY
—
Maury page id
psix-224745

Inspections, by type

…with no type recorded16
…past their stated due date3
Years with a record 9 calendar years (1985–2001)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it59259 - Dead Weight, Ton
18840 - Regulatory (Subpart C or D), Net Ton
32581 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 21

31 August 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 293427
9 August 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1071027
8 August 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 292718
27 July 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 292225
27 July 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1472283
15 January 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 285966
15 January 2001 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1470819
23 November 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 434870
15 January 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 424611
24 September 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 421179
17 November 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 527500
21 September 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 353623
21 September 1992 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1269793
13 May 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 466252
29 October 1990 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 340068
29 October 1990 Certificate of Compliance
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 921302
7 November 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 537803
6 December 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 327185
6 December 1988 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1209472
3 December 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 528426
28 March 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 301077

Deficiency record · 29

Lifesaving
Issued 27 July 2001 No resolution recorded
GRB LINES ON LIFEBOAT NOT BOUYANT AND MOUNTED TO CLOSE TO PROPELLER, TO BE REPLACED TO THE SATISFACTION OF THE USCG.
Condition: Unknown
Due 3 October 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 27 July 2001 No resolution recorded
FIRE PLAN DOES NOT SHOW LOCATION OF INTERNATIONAL SHORE CONNECTION, TO BE UPDATED TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 3 October 2001 — due date passed with no resolution recorded
Deck/Cargo
Issued 27 July 2001 Resolved
PROVE PROPER OPERATION OF CARGO LEVEL ALARMS PRIOR TO LOADING CARGO IN ANY US PORT TO THE SATISFACTION OF THE USCG.
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Electrical
Issued 27 July 2001 No resolution recorded
ELECTRICAL CONDUIT FOR TANK PRESSURE GAUGE SYSTEM BROKEN IN SEVERAL PLACES AND WRAPPED WITH CANVAS, TO BE REPAIRED TO SATISFACTION OF CLASS.
Condition: Unknown
Due 1 September 2001 — due date passed with no resolution recorded
Engineering
Issued 27 July 2001 Resolved
MAIN SALT WATER COOLING PIPE IS HOLED AND WASTED 6 FEET ABOVE PUMP, TO BE REPAIRED TO SATISFACTION OF CLASS PRIOR TO DEPARTING NY.
Condition: Unknown
Due 28 July 2001
Resolved 30 July 2001
Engineering
Issued 27 July 2001 Resolved
NUMBER 1 CYLINDER HEAD LEAKING FUEL OIL, TO BE REPAIRED TO THE SATISFACTIONOF CLASS PRIOR TO DEPARTING NY.
Condition: Unknown
Due 28 July 2001
Resolved 30 July 2001
Fire Fighting
Issued 15 January 2001 Resolved
FUEL TANK VENT FOR EMERGENCY FIRE PUMP CRACKED.REPAIR TO SATISFACTION OF CLASS PRIOR TO 14FEB01.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Accommodation/Occupational Safety
Issued 15 January 2001 Resolved
DOORS MISSING IN FOREPEAK STORES.REPLACE DOORS TO SATISFACTION OF CLASS PRIOR TO 15MAR01.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Lifesaving
Issued 15 January 2001 Resolved
THE RUDDER STOCK ON STBD LIFEBOAT WASTED AT ATTACHMENT POINTS.REPAIR TO SATISFACTION OF CLASS ONCE VSL IS GAS FREE,PRIOR TO 14FEB01.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Engineering
Issued 15 January 2001 Resolved
SEAWATER PUMP #2 LEAKING EXCESSIVELY.REPAIR TO THE SATISFACTION OF CLASS PRIOR TO 15MAR01.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Deck/Cargo
Issued 15 January 2001 Resolved
EMERGENCY STOPS IN CARGO PUMP ROOMS NOT MARKED/LABELED. LABEL TO THE SATISFACTION OF USCG PRIOR TO 14FEB01.
Condition: Unknown
Due 14 February 2001
Resolved 24 February 2001
Lifesaving
Issued 15 January 2001 Resolved
TRICING PENNANTS TOO LONG ON BOTH LIFEBOATS.REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTING.
Condition: Unknown
Due 24 February 2001
Resolved 24 February 2001
Lifesaving
Issued 15 January 2001 Resolved
OAR LOCKS SEIZED AND CHAINS MISSING.REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTING NEW YORK.
Condition: Unknown
Due 24 February 2001
Resolved 24 February 2001
Lifesaving
Issued 15 January 2001 Resolved
GRAB RAILS ON BOTH LIFEBOATS ARE LOOSE OR BROKEN. REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTING N.Y.
Condition: Unknown
Due 24 February 2001
Resolved 24 February 2001
Engineering
Issued 15 January 2001 Resolved
FANGUARD MISSING IN MAIN CONTROL. REPLACE GUARD TO SATISFACTION OF CLASS PRIOR TO 14FEB01.
Condition: Unknown
Due 14 February 2001
Resolved 24 February 2001
Navigation
Issued 24 September 1998 Resolved
INSTALL AUTOPILOT ALARM, PRIOR TO NEXT U.S. VOYAGE (TEMPORARY EQUIVALENCY GRANTED BY COTP NEW ORLEANS THIS PORT VISIT ONLY).
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Fire Fighting
Issued 24 September 1998 Resolved
PROVIDE SPANNER WRENCHES FOR EACH FIRE HOSE STATION, WHERE MISSING, PRIOR TO DEPARTURE FROM THE PORT OF NEW ORLEANS.
Condition: Unknown
Due 26 September 1998
Resolved 10 November 1998
Deck/Cargo
Issued 24 September 1998 Resolved
TACHOMETER FOR NUMBER ONE CARGO PUMP NOT PROPERLY WORKING OR CALIBRATED. _x001C_(RED CARGO SYSTEM)
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Deck/Cargo
Issued 24 September 1998 Resolved
SHOW PROPER OPERATION OF THE OIL DISCHARGE MONITORING EQUIPMENT UPON COMPLETION OF NEW INSTALLATION AND PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Documentation
Issued 21 September 1992 Resolved
SAFE MANNING CERTIFICATE NOT ON BOARD
Condition: Unknown
Due 19 November 1992
Resolved 19 November 1992
Engineering
Issued 21 September 1992 Resolved
DEMONSTRATE PROPER OPERATION OF OIL WATER SEPERATOR 15 PPM ALARM TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD INSPECTOR AT THE NEXT U.S. PORT. ALL MACHINERY SPACE SLOPS SHALL BE RETAINED ONBOARD OR DISCHARGED ASHORE UNTIL ALARM IS OPERATIONAL.
Condition: Unknown
Due 21 September 1992
Resolved 21 September 1992
Deck/Cargo
Issued 21 September 1992 Resolved
MAKE PERMANENT REPAIRS TO HYDRAULIC FLUID LEAK, STARBOARD ANCHOR WINDLASS, PRIOR TO NEXT U.S. VOYAGE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 September 1992
Resolved 21 September 1992
Accommodation/Occupational Safety
Issued 6 December 1988 Resolved
REPLACE NAMEPLATE ON SHIP'S MARINE SANITATION DEVICE.
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Engineering
Issued 6 December 1988 Resolved
INSTALL FLAME SCREENS ON ALL BUNKER TANK VENTS.
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Fire Fighting
Issued 6 December 1988 Resolved
PROVIDE KEYS TO DOORS AT ALL FIRE STATIONS.
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Deck/Cargo
Issued 6 December 1988 Resolved
REPAIR HIGH OXYGEN PERCENT ALARM ON INERT GAS SYSTEM. INOPERATIVE ALARM IS LOCATED IN CARGO CONTROL BOOTH.
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Lifesaving
Issued 6 December 1988 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Deck/Cargo
Issued 6 December 1988 Resolved
PLUG CARGO DISCHARGE CONTAINMENT HOLE AT STERN OF VESSEL
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988
Accommodation/Occupational Safety
Issued 6 December 1988 Resolved
REPAIR AERATOR PUMPS ON SHIP'S MARINE SANITATION DEVICE.
Condition: Unknown
Due 6 December 1988
Resolved 6 December 1988