MAURY USCG vessel records Sign in
← All vessels

CORCOVADO

CORCOVADO is a 1976 freight ship. The Coast Guard has recorded 31 inspections since 1984, most recently in June 2000, along with 14 deficiencies — 1 with no resolution recorded —.

Records from 1984 to 2000. Most recent: inspection, 19 June 2000.

Built
1976
Last inspected
19 June 2000
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7388798 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224815
Flag
BAHAMAS, THE
—
Maury page id
psix-224815

Inspections, by type

…with no type recorded20
…past their stated due date1
Years with a record 15 calendar years (1984–2000)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it51066 - Simplified, Net Ton
135000 - Dead Weight, Ton
66267 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 31

19 June 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 279186
6 August 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 447061
5 February 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 425343
5 February 1999 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 792093
17 August 1998 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 795656
14 February 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 413559
14 February 1998 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 777082
25 June 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 405180
17 February 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 400511
19 February 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 387960
19 June 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 470907
1 March 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 375613
8 November 1994 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1177653
17 August 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 499280
23 December 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 497415
23 December 1993 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1394040
12 October 1993 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1143083
11 October 1993 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 362065
12 May 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 686508
20 April 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 463477
4 March 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 457021
3 July 1992 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370487
3 July 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 345386
3 July 1991 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1245804
15 December 1990 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 451824
16 April 1990 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1240687
13 August 1988 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1343921
12 December 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 534611
29 May 1987 Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1003862
30 July 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 303628
29 April 1984 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 486999

Deficiency record · 14

Deck/Cargo
Issued 19 June 2000 No resolution recorded
PRIOR TO THE OPERATION OF THE INERT GAS FAN, MAKE PERMANENT REPAIRS TO THE ELECTRIC POWER CABLE.
Condition: Unknown
Due 21 June 2000 — due date passed with no resolution recorded
Deck/Cargo
Issued 8 November 1994 Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE CLASS REPORT ON THE PROPER OPERATION OF THE IGS SYSTEM ALARMS AND SHUTDOWNS, SPECIFICALLY THOSE REQUIRED BY SOLAS II-2 (62.19.1.1, 62.19.1.3, 62.19.3). PRIOR TO DEPARTURE THIS PORT, MAINTAIN PERSONS ON WATCH IN THE ENGINEROOM TO MONITOR IGS SYSTEM OPERATION
Condition: Unknown
Due 8 November 1994
Resolved 8 November 1994
Deck/Cargo
Issued 8 November 1994 Resolved
PRIOR TO NEXT U.S. PORT, MAKE PERMANENT REPAIRS AND PROVIDE A REPORT FROM THE CLASSIFICATION SOCIETY CONCERNING PERMANENT REPAIRS TO THE CRUDE OIL WASHING MACHINE FOR THE #3 CENTER CARGO TANK. (PRIOR TO DEPARTING ANCHOR, MAKE TEMPORARY REPAIRS TO THE SMALL HOLE.)
Condition: Unknown
Due 8 November 1994
Resolved 8 November 1994
Deck/Cargo
Issued 8 November 1994 Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE WRITTEN EVIDENCE OF A 150% MAWP HYDROSTATIC TEST OF BUNKER PIPING. (PRIOR TO BUNKERING IN THIS PORT, PROVIDE A STATEMENT FROM THE MASTER OF SATISFACTORY COMPLETION OF A 100% MAWP TEST OF THE BUNKER PIPING.)
Condition: Unknown
Due 8 November 1994
Resolved 8 November 1994
Construction/Loadline
Issued 12 October 1993 Resolved
TWO CLASS III FRACTURES FOUND IN THE #2 CENTER BALLAST TANK FWD, PORT BULKHEAD, #2 TABLE PLATE.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Fire Fighting
Issued 12 October 1993 Resolved
FIRE CONTROL PLAN DOES NOT REFLECT LOCATION OF SAFETY EQUIPMENT.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Lifesaving
Issued 12 October 1993 Resolved
NO SPAN GAS FOR CALIBRATION OF PORTABLE EXPLOSIMETER.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Lifesaving
Issued 12 October 1993 Resolved
15 MAN ZODIAK LIFERAFT CONTAINER IS DAMAGED.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Documentation
Issued 12 October 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Engineering
Issued 12 October 1993 Resolved
VESSELS BUNKER LINE IS FITTED WITH A SOFT PATCH AND HAS TWO EPOXY COATED AREAS OF HEAVY PITTING NEAR VESSEL CENTERLINE.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Lifesaving
Issued 12 October 1993 Resolved
STARBOARD DAVIT, AFT ARM PULLEY HOUSING WASTED IN TWO AREAS.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Fire Fighting
Issued 12 October 1993 Resolved
NO FIRE CONTROL PLAN ON THE WEATHERDECK.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Accommodation/Occupational Safety
Issued 12 October 1993 Resolved
STORES IN PASSAGEWAY, STBD SIDE, MAIN DECK.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Deck/Cargo
Issued 16 April 1990 Resolved
VESSEL MUST CONDUCT STATIC LIQUID PRESSURE TEST OF CARGO TRANSFER PIPE SYSTEM IN ACCORDANCE WITH 33CFR 156.170 (4) AND LOG RESULTS PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.