Records from 1985 to 1998. Most recent: inspection, 5 December 1998.
Inspection history · 34
5 December 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 423381
5 December 1998
Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 806565
24 May 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 523645
14 August 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 406902
14 August 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 406906
14 August 1997
Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 786303
29 August 1996
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 394343
4 August 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 381373
23 January 1995
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 520373
19 January 1995
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 492369
10 December 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 485270
15 July 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 674925
28 June 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 368077
18 March 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 365262
18 March 1994
Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 854850
16 March 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 156917
27 June 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 359071
17 May 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 358223
4 November 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 354605
4 November 1992
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1133730
28 August 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 470764
6 July 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 443052
17 November 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 347085
15 October 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1248569
3 October 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 457323
3 October 1991
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 944098
24 May 1990
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 934966
21 December 1989
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 516940
18 March 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 329200
18 March 1989
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 900476
11 December 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 320251
13 April 1987
Administrative
Administrative · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1329991
13 April 1987
Administrative
Administrative · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1331235
3 October 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 304640
Unknown
Issued 28 June 1994
Resolved
Vessel did not properly segragate their garbage. Discharged plastics in U.S. waters.
Condition: Unknown
Due 28 June 1994
Resolved 15 July 1994
Deck/Cargo
Issued 18 March 1994
Resolved
PRIOR TO NEXT U.S. PORT, PRESSURE TEST THE CARGO PIPING TO 1.5 TIMES THE MAXIMUM PRESSURE THE PIPING IS SUBJECTED TO IN SERVICE OR PROVIDE A RECORD OF SUCH TEST COMPLETED WITHIN THE LAST YEAR. (TESTED TO 14 BAR ON 14MAR94 BUT PUMP PRESSURE CURVES SHOW MAWP IS 11 BAR.)
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Fire Fighting
Issued 4 November 1992
Resolved
CLEAN PLUGGED SPRINKLER HEADS TO PORT & STBD FORWARD PAINT LOCKIER FIRE FIGHTING SYSTEM PRIOR TO NEXT U.S. PORT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 November 1992
Resolved 4 November 1992
Fire Fighting
Issued 4 November 1992
Resolved
MAKE PERMANENT REPAIRS TO WASTED HOLE ONTOP OF FOAM MONITOR #3 PRIOR TO DISCHARGING/LOADING CARGO AT NEXT U.S. PORT. TEMPORARY REPAIRS - SAT_x001C_
Condition: Unknown
Due 4 November 1992
Resolved 4 November 1992
Deck/Cargo
Issued 3 October 1991
Resolved
PROVIDE ADEQUATE DRAIN PLUGS (MECHANICAL) FOR TWO DIESEL OIL SETTLING TANK VENTS CONTAINMENTS (STBD AFT) PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991
Documentation
Issued 3 October 1991
Resolved
OBTAIN ENGLISH TRANSLATION OF OIL TRANSFER PROCEDURES AND PROVIDE SAME TO COGNIZANT OFFICER IN CHARGE MARINE INSPECTION AT THE NEXT U.S. PORT OF CALL
Condition: Unknown
Due 15 October 1991
Resolved 15 October 1991
Fire Fighting
Issued 3 October 1991
Resolved
MAKE PERMANENT REPAIRS TO LEAKING HYDRAULIC RETURN LINE FOR EMERGENCY FIRE PIPING LOCATED AFT MAIN DECK STBD SIDE OUTSIDE CARGO PUMPROOM. REPAIR PRIORTO CARGO TRANSFER. _x001C_ _x001C_
Condition: Unknown
Due 15 October 1991
Resolved 15 October 1991
Engineering
Issued 3 October 1991
Resolved
MAKE ALL FLAME SCREENS ON BUNKERING FUEL AND LUBE OIL VENTS VAPORTIGHT AROUND VENT HOUSINGS PRIOR TO RETURNING TO A U.S. PORT.
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991
Deck/Cargo
Issued 3 October 1991
Resolved
MAKE PERMANENT REPAIRS TO LEAKING CARGO STEAM HEATING LINE AT NUMBER TWO CENTER CARGO TANK, WHERE STEAM IS INTERFERING WITH FIRE MAIN VALVE. TEMPORARY DEFLECTOR IN PLACE TO PERMIT OPERATION OF FIRE MAIN VALVE. CORRECT PRIOR TO TRANSFERRING NEXT CARGO.
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991
Navigation
Issued 3 October 1991
Resolved
PROVIDE TURNING RADIUS INFORMATION FOR VESSEL IN A BALLAST CONDITION FOR THE MANEUVERING INFORMATION POSTED IN THE WHEELHOUSE. PROVIDE PRIOR TO RETURN TO THE U.S.
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991
Fire Fighting
Issued 3 October 1991
Resolved
PROVIDE LIFELINE FOR FOURTH FOR EMERGENCY FIREMAN'S OUTFIT PRIOR TO DEPARTURE FROM THE PORT OF PHILADELPHIA.
Condition: Unknown
Due 15 October 1991
Resolved 15 October 1991
Lifesaving
Issued 3 October 1991
Resolved
PROVIDE PERMANENT MEANS OF CLOSURE OF AN OPEN ELECTRICAL STUFFING TUBE IN WAY OF FORWARD SIDE OF DECKHOUSE SUPERSTRUCTURE ON PORTSIDE APPROX 1' OFF DECK NEAR CORNER OF CARGO PUMPROOM. CORRECT PRIOR TO TRANSFERRING CARGO.
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Deck/Cargo
Issued 3 October 1985
Resolved
VESSEL DID NOT HAVE STANDARD DISCHARGE CONNECTION ONBOARD AS REQUIRED BY 33CFR155.430/ MARPOL73/78, REG 19.
Condition: Unknown
Due 3 October 1985
Resolved 3 October 1985