Records from 1985 to 1999. Most recent: inspection, 13 April 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
13 April 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 427584
30 May 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 351580
30 May 1992
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 952110
30 May 1992
MARPOL Annex I Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 953195
30 May 1992
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 955006
30 May 1992
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1263405
30 July 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1251876
25 June 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 344728
2 March 1991
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1307496
24 October 1990
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 921770
9 October 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 339996
9 October 1990
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1221374
4 April 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 441130
8 October 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 333318
8 October 1989
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1199528
24 January 1989
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1208732
16 August 1988
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1343160
12 February 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 321346
12 February 1988
MARPOL Annex II Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1024902
6 September 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 311360
6 September 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1330119
12 September 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 304565
Deck/Cargo
Issued 13 April 1999
Resolved
PORT ANCHOR WINCH LEAKING GEAR OIL.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Navigation
Issued 13 April 1999
Resolved
PORT STEERING PUMP MOTOR CONTROLLER SHORTED.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Electrical
Issued 13 April 1999
Resolved
FUEL FILTER HOUSING LEAKING.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Deck/Cargo
Issued 30 July 1991
Resolved
MAKE PERMANENT REPAIRS TO NO. 4 CARGO PUMP RISER PIPING NLT 01SEP91. VSL MAY NOT USE #4 CARGO PUMP WHEN OPERATING IN U.S. WATERS UNTIL THIS REQUIREMENT IS CLEARED.
Condition: Unknown
Due 30 July 1991
Resolved 30 July 1991
Engineering
Issued 9 October 1990
Resolved
OILY WATER SEPERATOR DETECTOR INOP.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Deck/Cargo
Issued 9 October 1990
Resolved
BUNKER TANK FLAME SCREENS CLOGGED AND IMPROPER MESH.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Documentation
Issued 9 October 1990
Resolved
NO OIL TRANSFER PROCEDURES ON BOARD.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Deck/Cargo
Issued 9 October 1990
Resolved
OPERATION OF REMOTE STOP FOR #1 CARGO PUMP NOT TESTED.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Navigation
Issued 9 October 1990
Resolved
BRIDGE MANOUVERING INFO SHEET IMPROPER. (NO WARNING/W BALLEST CONDITION INFO).
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Navigation
Issued 9 October 1990
Resolved
NO TIDAL CURRENT TABLES ON BOARD.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Electrical
Issued 9 October 1990
Resolved
IGS SYSTEM PANNEL LIGHTS INOP.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Fire Fighting
Issued 9 October 1990
Resolved
NO FOAM ANALYSIS REPORT HAS NOT BEEN TESTED SENCE 1987.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Documentation
Issued 9 October 1990
Resolved
NO POLLUTION PLACARD POSTED IN ER BY BILGE PUMP OR OWS.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Navigation
Issued 12 February 1988
Resolved
PROVIDE REPAIRS FOR THE AUTOMATIC RADAR PLOTTING AID ON BOARD IN ACCORDANCEWITH 33CFR164.38(B).
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Documentation
Issued 12 February 1988
Resolved
PROVIDE OIL TRANSFER PROCEDURES ON BOARD FOR CARGO AND BUNKERING OPS IN ACCORDANCE WITH 33CFR155.720.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Deck/Cargo
Issued 12 February 1988
Resolved
PROVIDE REPAIRS TO THE HIGH O2 AUDIBLE ALARM IN THE CARGO CONTROL ROOM.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Engineering
Issued 12 February 1988
Resolved
PROVIDE REPAIRS TO THE OILY WATER SEPARATOR ON BOARD & PROVE PROPER OPERATION TO U.S.C.G.. RETAIN ALL MACHINERY SLOPS ONBOARD UNTIL REPAIRS AREMADE AND PROPER OPS ARE PROVEN IN ACCORDANCE WITH MARPOL.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988