Records from 1985 to 2005. Most recent: inspection, 14 October 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
14 October 2005
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2568415
17 May 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 105773
25 September 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 282552
3 July 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 279358
25 May 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 429036
31 May 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 417070
31 May 1998
Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 793061
15 December 1997
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1118203
30 May 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 99076
28 May 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 404373
22 November 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 192484
22 November 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 754062
13 May 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 378657
7 September 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1174420
17 May 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 366958
17 May 1994
Tank Vessel Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1398072
30 May 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 358722
30 May 1993
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1138674
26 March 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 349714
26 March 1992
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 951462
22 March 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 342688
22 March 1991
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1305938
31 December 1989
MARPOL Annex I Examination · Certificate of Compliance
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 903225
14 November 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 305508
Lifesaving
Issued 3 July 2000
Resolved
Repair/renew as original steam leaks in engine room and on bow. SOLAS 74 (amended) II-1/26
Condition: Unknown
Due 3 August 2000
Resolved 26 September 2000
Fire Fighting
Issued 3 July 2000
Resolved
Update Fire Control plans to show different class divisions of structural fire protection. SOLAS 74 (amended) II-2/20
Condition: Unknown
Due 3 August 2000
Resolved 26 September 2000
Fire Fighting
Issued 3 July 2000
Resolved
Ensure doors to chemical room and rope stores latch in the closed postion and provide class-A structural fire protection. SOLAS 60 II/36
Condition: Unknown
Due 3 August 2000
Resolved 26 September 2000
Deck/Cargo
Issued 3 July 2000
Resolved
Prove proper operation of #3 cargo pump shutdown. Pump not to be used in USwaters until repaired.
Condition: Unknown
Due 3 August 2000
Resolved 26 September 2000
Fire Fighting
Issued 28 May 1997
Resolved
FIRE MONITOR PIPING FOR NUMBER 2 AND 3 MONITORS HOLED.
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Deck/Cargo
Issued 17 May 1994
Resolved
RENEW IGS SYSTEM DECKWATER SEAL OVERFLOW OVERBOARD PIPING , TO THE SATISFACTION OF CLASSIFICATION SOCIETY UPON COMPLETION OF TRANSFER AND PRIOR TO RE-ENTRY INTO U.S. WATERS.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Fire Fighting
Issued 17 May 1994
Resolved
RENEW LOW PRESSURE CO2 CONDENSER PIPING, TO THE SATISFACTION OF CLASSIFICATION SOCIETY UPON COMPLETION OF TRANSFER AND PRIOR TO RE-ENTRY INTO U.S. WATERS.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Deck/Cargo
Issued 26 March 1992
Resolved
MUST REPAIR #1 MAIN CARGO TRANSFER LINE SOFT PATCH (BOLTED CLAMP) LOWER DECK PUMPROOM PRIOR TO RE-ENTRY INTO U. S. WATERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 March 1992
Resolved 26 March 1992
Navigation
Issued 22 March 1991
Resolved
REPAIR RADAR PRIOR TO DEPARTING PRESENT MOORING LOCATION_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Construction/Loadline
Issued 22 March 1991
Resolved
REPAIR DAMAGE TO THE NUMBER ONE CARGO TANK PRIOR TO RETURNING TO U.S._x001C_ WATERS _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Navigation
Issued 31 December 1989
Resolved
ARPA RADAR INOPERABLE.
Condition: Unknown
Due 31 December 1989
Resolved 31 December 1989