Records from 1985 to 1990. Most recent: inspection, 16 December 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
16 December 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 340834
16 December 1990
Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 900900
7 July 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 338119
7 May 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 470964
16 September 1989
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 332671
16 September 1989
Certificate of Compliance
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1349047
2 July 1989
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 453559
17 April 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 456328
2 November 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 327082
31 October 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 326540
31 October 1988
Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1201657
11 March 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 322357
7 March 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 322356
25 February 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 322355
24 February 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 322353
24 February 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 322354
22 February 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 454726
22 February 1988
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1330765
28 July 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 462221
13 April 1987
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 315384
13 April 1987
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1317597
13 April 1987
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1318994
1 August 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 310545
10 April 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 441177
25 March 1986
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 307704
13 October 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 304881
13 October 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1301932
Documentation
Issued 16 December 1990
Resolved
33 CFR 155.750 (a) The oil transfer procedures required by 155.720 must contain, either in the order listed or by use of a cross-reference index page; [lists duties, procedures (1) thru (10)], i.e. The oil transfer procedures were not complete and not listed in the appropriate order._x001C_
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Documentation
Issued 16 December 1990
Resolved
33 CFR 151.25 (h) Each completed page of the Oil Record Book shall be signed by the master or other person having charge of a ship, i.e. the master signed the current page before it was completed._x001C_ _x001C_
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Documentation
Issued 16 December 1990
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE. TO BE COMPLETED PRIOR TO ANY TRANSFER OPERATIONS.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Deck/Cargo
Issued 16 December 1990
Resolved
#6 CENTER CARGO TANK ULLAGE OPENING FLAME SCREEN MISSING.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Deck/Cargo
Issued 16 December 1990
Resolved
#7 CENTER TANK P/V VALVE FLAME SCREEN DETERIORATED. MUST BE REPLACED PRIOR TO TRANSFER OF CARGO.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Unknown
Issued 16 December 1990
Resolved
STARBOARD VENTILATION FAN MOTOR FOR PUMPROOM INOPERATIVE. NEW FAN INSTALLEDPRIOR TO TRANSFER.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Navigation
Issued 16 September 1989
Resolved
VESSEL DID NOT HAVE AN OPERATIONAL ARPA. 333 CFR 164.38(B)(1). VESSEL IS18013 GROSS TONS AND VESSEL TRANSITTED NARRGANSETT BAY ON 18 SEP 89.
Condition: Unknown
Due 16 September 1989
Resolved 16 September 1989
Documentation
Issued 2 November 1988
Resolved
33 CFR 155.750(A)(1)(A)(II) THE OIL TRANSFER PROCEDURES DID NOT CONTAIN THE REQUIRED INFORMATION (I.E.: A LIST OF PRODUCTS BEING TRANSFERED, GENERIC OR CHEMICAL NAME, CARGO INFORMATION AS DESCRIBED IN 33 CFR 154.310 (A)(1)(II), PROCEDURES FRO EMPTYING CONTAINMENT AND TOPPING OFF TANKS.)
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Navigation
Issued 31 October 1988
Resolved
33 CFR 164.35(H)(I) VESSEL DID NOT HAVE ONBOARD AN WORKING ECHO SOUNDING DEVICE.
Condition: Unknown
Due 31 October 1988
Resolved 31 October 1988
Navigation
Issued 31 October 1988
Resolved
33 CFR 164.38(B)(1) THE TANK VESSEL, WHICH WAS OVER 10,000 GROSS TONS,WAS NOT EQUIPPED WITH AN WORKING AUTOMATIC RADAR PLOTTING (ARPA) DEVICE.
Condition: Unknown
Due 31 October 1988
Resolved 31 October 1988
Navigation
Issued 31 October 1988
Resolved
33 CFR 164.40(A)(1)(II) VESSEL DID NOT HAVE A WORKING SPEED AND DISTANCE MEARSURING DEVICE
Condition: Unknown
Due 31 October 1988
Resolved 31 October 1988
Unknown
Issued 31 October 1988
Resolved
33 CFR 159.7(A) THE VESSEL WAS NOT EQUIPPED WITH AN OPERABLE TYPE I,II,OR III MARINE SANITATION DEVICE.
Condition: Unknown
Due 31 October 1988
Resolved 31 October 1988
Unknown
Issued 31 October 1988
Resolved
MAKE PERMANENT REPAIR TO MARINE SANITATION FLUSHING SYSTEM PRIOR TO ENTRY TO NEXT US PORT.
Condition: Unknown
Due 31 October 1988
Resolved 31 October 1988
Deck/Cargo
Issued 22 February 1988
Resolved
INSTALL CARGO CONTROL MONITOR AND EQUIPMENT PRIOR TO RE-ENTRY NEXT U.S. PORT
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Fire Fighting
Issued 22 February 1988
Resolved
SOFT PATCHES IN HYDRAULIC FIRE PUMP LINES. REPAIR HYDRAULIC LINES AND TEST FIRE PUMP PRIOR TO RE-ENTRY NEXT U.S. PORT-MIEI
Condition: Unknown
Due 22 February 1988
Resolved 22 February 1988
Documentation
Issued 13 April 1987
Resolved
VESSEL TRANSFERRING WITH NO DECLARATION OF INSPECTION.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Deck/Cargo
Issued 13 April 1987
Resolved
NO WARNING SIGN POSTED AT THE GANGWAY
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Navigation
Issued 13 April 1987
Resolved
CHART 12349 NOT ON BOARD.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Deck/Cargo
Issued 13 April 1987
Resolved
MANIFOLD TO HOSE CONNECTION OF PORT SIDE CARGO LINE 3 LEAKING.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Documentation
Issued 13 April 1987
Resolved
DISCHARGE OF OIL PROHIBITED PLACARD NOT POSTED.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Documentation
Issued 13 April 1987
Resolved
PLANVIEW OF CARGO NOT COMPLETED IN CARGO OIL RECORD BOOK PART II.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Documentation
Issued 13 April 1987
Resolved
ENTRIES NOT MADE ON THE OCCASION OF LOADING AND UNLOADING CARGO OIL.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Documentation
Issued 13 April 1987
Resolved
OIL RECORD BOOK PART 1 NOT PROPERLY MAINTAINED.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Deck/Cargo
Issued 13 April 1987
Resolved
CARGO PIPING BEING USED FOR THE TRANSFER OF OIL NOT TESTED IN ACCORDANCE WITH 33 CFR 156.170.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Navigation
Issued 13 April 1987
Resolved
CHARTS 12331, 12326, 12327, 12333, 12334 AND 12335 NOT CORRECTED UP TO DATE
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Deck/Cargo
Issued 13 April 1987
Resolved
OIL CARGO DISCHARGE MONITOR INOPERATIVE.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Deck/Cargo
Issued 13 April 1987
Resolved
FLAME SCREENS MISSING FROM 18 TO 21 VENT HEADERS.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Navigation
Issued 25 March 1986
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Navigation
Issued 25 March 1986
Resolved
33 CFR 164.33(A)(3)(II): THE VESSEL DID NOT HAVE ON BOARD A CURRENT EDITIONOF, OR APPLICABLE CURRENTLY CORRECTED EXTRACT FROM, THE TIDAL CURRENT TABLEFOR THE AREA TO BE TRANSITED.(BOSTON HARBOR AND APPROACHES)
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Deck/Cargo
Issued 25 March 1986
Resolved
46 CFR 35.30-10 THE ULLAGE HOLES (WHICH HAD NOT BEEN UNDER THE SUPERVISION OF THE SENIOR MEMBERS OF THE CREW ON DUTY AND WHICH WERE TO TANKS WHICH WERE NOT GAS FREE) WERE OPEN/COULD NOT BE PROPERLY SHUT DUE TO SEVERLY DETERIORATED OR MISSING GASKETS.
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Navigation
Issued 25 March 1986
Resolved
33 CFR 88.05 THE VESSEL DID NOT HAVE ON BOARD A COPY OF THE INLAND NAVIGATION RULES.
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Navigation
Issued 25 March 1986
Resolved
33 CFR 164.33(A)(2)(II):THE VESSEL DID NOT HAVE A CURRENTLY CORRECTED COPY OF, OR APPLICABLE CURRENTLY EXTRACT FROM, THE COAST GUARD LIGHT LIST FOR THE AREA TO BE TRANSITED.(BOSTON HARBOR AND APPROACHES)
Condition: Unknown
Due 1 August 1986
Resolved 25 March 1986
Navigation
Issued 25 March 1986
Resolved
33 CFR 164.11(Q): THE OPERATOR OF THE VESSEL DID NOT LOG THE TESTS REQUIRED BY 33 CFR 164.25 IN THE VESSEL'S LOG.
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Documentation
Issued 25 March 1986
Resolved
33 CFR 155.740: THE VESSEL WITH A CAPACITY OF APPX 248,842.5 BBLS OF OIL, DID NOT HAVE ON BOARD OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Documentation
Issued 25 March 1986
Resolved
33 CFR 155.820(A): THE OPERATOR OF THE VESSEL DID NOT PROVIDE, FOR INSPECTION BY THE COTP, A WRITTEN RECORD OF EACH PERSON CURRENTLY DESIGNA- TED AS A PERSON IN CHARGE OF AN OIL TRANSFER.
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Deck/Cargo
Issued 25 March 1986
Resolved
46 CFR 32.55-20: THE FLAME SCREENS ON BOARD THE VESSEL DID NOT MEETTHE REQUIREMENTS OF 46 CFR 30.10-25.(SEVERAL SCREENS COVERING THE ULLAGE OPENINGS WERE HOLED AND OF INADEQUATE MESH SIZE.
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Deck/Cargo
Issued 13 October 1985
Resolved
CARGO PUMP REMOTE SHUT DOWN NOT PROPERLY LABELED.
Condition: Unknown
Due 13 October 1985
Resolved 13 October 1985
Deck/Cargo
Issued 13 October 1985
Resolved
VENT PIPING FOR NR2 AND NR6 STBD CARGO TANKS WERE WASTED.
Condition: Unknown
Due 13 October 1985
Resolved 13 October 1985
Deck/Cargo
Issued 13 October 1985
Resolved
FLAME SCREENS DID NOT PROPERLY FIT THE ULLAGE HOLES ON ALL CARGO TANKS.
Condition: Unknown
Due 13 October 1985
Resolved 13 October 1985
Deck/Cargo
Issued 13 October 1985
Resolved
REPAIR LEAKING PRESSURE GAUGE IN NO. 1 CARGO TRANSFER LINE IN VICINITY TO TANK NO. 5 STARBOARD PRIOR TO RETURNING U.S. WATERS.
Condition: Unknown
Due 13 October 1985
Resolved 13 October 1985
Deck/Cargo
Issued 13 October 1985
Resolved
ENSURE PRESSURE VACUUM VALVES ARE OPERATING AT PROPER PRESSURE PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 13 October 1985
Resolved 13 October 1985
Deck/Cargo
Issued 13 October 1985
Resolved
REPAIR ALL FLAME SCREENS PROVIDING PROPER FIT WITH NO OPENINGS PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 13 October 1985
Resolved 13 October 1985
Deck/Cargo
Issued 13 October 1985
Resolved
REPAIR HOLED VENT LINES FROM TANKS TWO AND SIX STARBOARD PRIOR TO RETURNINGU.S. WATERS
Condition: Unknown
Due 13 October 1985
Resolved 13 October 1985