Records from 1984 to 1997. Most recent: inspection, 17 July 1997.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
17 July 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 405726
18 December 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 914817
13 December 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 340751
13 December 1990
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 914451
1 January 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 529235
1 January 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1008004
1 January 1988
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1318799
24 October 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 312230
24 October 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1013550
12 June 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 471130
28 January 1986
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1304459
27 January 1986
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 996770
26 January 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 306762
24 June 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 302728
22 June 1984
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 296823
Deck/Cargo
Issued 13 December 1990
Resolved
Oil transfer piping not static liquid pressure tested within the last year as required by 33CFR156.170(f)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Construction/Loadline
Issued 13 December 1990
Resolved
RENEW GASKET TO AFT HATCH TO MAIN STEERING ROOM, APPROX 5FT BY 9FT.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Deck/Cargo
Issued 13 December 1990
Resolved
MAKE PERMANENT REPAIRS TO HOLED STEAM LINE APPROX 1/4 INCH TO FWD BOW _x001C_ MOORING WINCH ON CENTERLINE OF VESSEL.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Documentation
Issued 13 December 1990
Resolved
LOADLINE CERTIFICATE REQUIRES ANNUAL ENDORSEMENT FOR PERIOD JUNE 90.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Documentation
Issued 26 January 1986
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 26 January 1986
Resolved 26 January 1986
Deck/Cargo
Issued 24 June 1985
Resolved
VESSEL HAS FIBERGLASS TANK COVERS IN VIOLATION OF SOLAS 74 REG 57, COMDT ACTION PENDS FOR DESIGN APPROVAL/DISAPPROVAL.
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985
Documentation
Issued 24 June 1985
Resolved
VESSEL DID NOT HAVE A COMPLETED OIL TRANSFER PROCEDURE IN THAT IT WAS MISSING THE CARGO INFORMATION ON OIL TRANSFER PROCEDURES, AS REQUIRED BY 33 CFR 155.750(A)(1)(II).
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985
Unknown
Issued 24 June 1985
Resolved
REMOVE HOSES ON CARGO CONTAINMENT VALVES AT CARGO CROSSOVER MANIFOLDS PORT AND STARBOARD SIDES.
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985
Navigation
Issued 24 June 1985
Resolved
VESSEL DID NOT HAVE ONBOARD A LOCAL CHART 11347 OR THE FOREIGN EQUIVALENT AS REQUIRED BY 33 CFR 164.33(A)(1).
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985
Navigation
Issued 24 June 1985
Resolved
CONDUCT EXAM AND NECESSARY REPAIR TO THE STEERING GEAR SYSTEM TO SAT. OF ANABS SURVEYOR: REPAIR LEAKING SEAL #1 HYDRAULIC RAM STBD SIDE, EXAMINE GROOVING ON BOTH RAMS, REPAIR LEAKING SEAL ON #1 STEERING GEAR PUMP, EVALUATE TIME NEEDED TO SWING RUDDER FROM 35 DEG STBD TO 35 DEG PORT(62 SEC
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985
Deck/Cargo
Issued 24 June 1985
Resolved
VESSEL DID NOT HAVE ONBOARD FOR THE INSPECTOR AN UPDATED RECORD OF THE INSPECTION AND TESTS ON THE CARGO PIPING SYSTEM AS REQUIRED BY 33 CFR 156. 170. THIS RECORD WILL BE AVAILABLE FOR THE NEXT CG INSPECTORS.
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985
Deck/Cargo
Issued 24 June 1985
Resolved
REPAIR ALL CARGO TANK ULLAGE OPENING FLAME SCREENS AS REQUIRED.
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985
Deck/Cargo
Issued 24 June 1985
Resolved
REPLACE FLAME SCREENS FOR BUNKER TANKS AFT AND THOSE VENTS LOCATED ON PORT AND STARBOARD SIDES OF THE DECK HOUSE.
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985
Deck/Cargo
Issued 24 June 1985
Resolved
DEMONSTRATE CALIBRATION OF IGS OXYGEN METER TO THE SATISFACTION OF CG BOARDING TEAM. CHEIF ENGINEER DID NOT KNOW HOW TO CALIBRATE THE SYSTEM.
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985
Deck/Cargo
Issued 24 June 1985
Resolved
VESSEL DID NOT HAVE ONBOARD ANY FITTINGS FOR MEASURING THE OXYGEN CONCENT- RATION IN CARGO TANKS AS REQUIRED BY 46 CFR 32.53-65(B).
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985
Fire Fighting
Issued 24 June 1985
Resolved
VESSEL NEEDS TO REPLACE FIRE HOSES WHERE NEEDED. APPROXIMATELY 8 FIRE STATIONS NEED THE HOSES REPLACED.
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985
Fire Fighting
Issued 24 June 1985
Resolved
PROVIDE REPLACEMENT FIRE FIGHTING NOZZLES FOR DECK FIRE STATIONS WHERE NEEDED.
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985
Fire Fighting
Issued 24 June 1985
Resolved
PROVIDE SUITABLE SPANNER WRENCHES FOR ALL DECK FIRE STATIONS.
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985
Electrical
Issued 24 June 1985
Resolved
REPAIR MOUNT FOR EXPLOSION PROOF LIGHT LOCATED ON PORT SIDE LOWER LEVEL OF CARGO PUMP ROOM.
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985
Deck/Cargo
Issued 24 June 1985
Resolved
REPAIR RUPTURED STEAM LINE ON DECK PORT SIDE OVER #4C CARGO TANK.
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985
Deck/Cargo
Issued 24 June 1985
Resolved
REMOVE ALL EXCESS CARGO OIL FROM PUMP ROOM BILGES.
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985
Deck/Cargo
Issued 24 June 1985
Resolved
COMPLETE PERMANENT REPAIRS IN WAY OF TEMPORARY REPAIRS TO LEAKING HYDRAULICLINE ON DECK PORT SIDE, FORWARD OF #4C CARGO TANK.
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985