MAURY USCG vessel records Sign in
← All vessels

AXION

AXION is a 1976 freight ship. The Coast Guard has recorded 46 inspections since 1984, most recently in October 2002, along with 41 deficiencies and 5 operational controls.

Records from 1984 to 2002. Most recent: inspection, 10 October 2002.

Built
1976
Last inspected
10 October 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7400326 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224941
Flag
GREECE
—
Maury page id
psix-224941

Inspections, by type

…with no type recorded42
Years with a record 17 calendar years (1984–2002)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it11065 - Regulatory (Subpart C or D), Net Ton
11065 - Convention (Subpart B), Net Ton
17014 - Regulatory (Subpart C or D), Gross Ton
17014 - Convention (Subpart B), Gross Ton
30242 - Dead Weight, Metric Ton
37094 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

AMERICAN PILLAR Towing Vessel · MISLE 145740 · 11 April 2002 · activity 1611995

Inspection history · 46

10 October 2002 Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1687790
20 September 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1678335
22 June 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1634902
11 April 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1611995
9 April 2002 Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1602952
9 April 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1609841
17 August 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 293005
18 April 2000 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 277020
8 May 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 428118
8 April 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 169984
8 April 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 427820
15 October 1998 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 421477
4 August 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 418865
5 February 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 412604
10 September 1997 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 407750
21 April 1997 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 402591
10 September 1996 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 395302
29 August 1996 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 394714
26 August 1996 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 394314
2 June 1996 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 391554
25 May 1996 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 391697
23 May 1996 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 391535
22 November 1994 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 372257
10 August 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 369355
9 December 1993 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 645807
6 December 1993 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 362671
28 April 1993 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 357925
19 May 1992 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 645809
27 April 1992 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 349924
4 October 1991 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 346309
26 August 1991 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 645808
5 August 1991 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 345009
25 July 1991 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 346059
23 July 1991 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 344865
22 April 1991 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 343266
15 November 1990 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 490393
6 August 1990 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 338436
13 January 1990 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 334764
19 January 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 327900
25 September 1987 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 318645
15 October 1986 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 312187
16 September 1985 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 304217
6 September 1985 Damage Survey
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1294265
11 June 1985 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 524575
25 October 1984 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 298658
10 July 1984 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 439963

Deficiency record · 41

Engineering › Diesel Engine (auxiliary)
Issued 20 September 2002 Resolved
The No. 1 generator has several major cooling water leaks and a fuel oil leak on the #3 cylinder. The vessel is prohibited from operating the generator while transiting the Mississippi River until repaired to the satisfaction of class but no later than the next port. LEGACY COMPONENT DESC: Cylinder Head
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 10 October 2002
Resolution: Receivied class report stating all leaks have been repaired.
Engineering › Diesel Engine (auxiliary)
Issued 20 September 2002 Resolved
The No. 3 generator has several cylinder head cooling water leaks. LEGACY COMPONENT DESC: Cylinder Head
Action required: 705 - Other - as specified
Due 27 September 2002
Resolved 28 September 2002
Resolution: Received class report stating that the No''s 1, 2, & 3 cylinders had cooling water rubber seals replaced and tested with satisfactory results.
Engineering › Diesel Engine (auxiliary)
Issued 20 September 2002 Resolved
All three generators are missing several of the high pressure fuel line jackets. Also, the installed drain lines for the jackets are missing or not connected. Replace as original or to the satisfaction of class. Class imposed condition of class to replace the jackets and reconnect the drain lines LEGACY COMPONENT DESC: Injector (fuel injection)
Action required: 705 - Other - as specified
Due 31 October 2002
Resolved 10 October 2002
Resolution: Received class report attesting to the repair of the repair of the drain lines and high pressure fuel line jackets.
Engineering › Steering Gear System
Issued 20 September 2002 Resolved
The port steering pump was found leaking approximately 1 pint of oil per minute from the shaft seal. The seal was changed and it still has substantial leakage and the housing became extremely hot after several minutes of operation. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 20 September 2002
Resolved 24 September 2002
Resolution: Received class report from [name withheld] stating that the port steering pump seal was replaced and tested with satisfactory results.
Pollution Prevention/Response › Prevention Equipment
Issued 20 September 2002 Resolved
The oily water separator's automatic stopping device and alarm would not activate at 15 ppm. It appeared to be set at 44 ppm. Vessel crew reset to 05 ppm with flushing water. Vessel is prohibited from operating the oily water separator until proof of operation and calibration is provided. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 28 September 2002
Resolution: Received class report and tech report stating that the control monitor was replaced and tested with satisfactory results.
Navigation › Collision/Grounding Avoidance
Issued 20 September 2002 Resolved
The echo depth sounder does not work. LEGACY COMPONENT DESC: Echo-sounding Device
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 24 September 2002
Resolution: Received tech report from [name withheld] stating that the echo depth sounder was repaired and tested with satisfactory results.
Construction/Loadline › Hull
Issued 9 April 2002 Resolved
Wastage and pitting of hull plating below water line in engine room on port and starboard side. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2002
Resolved 19 April 2002
Resolution: Received satisfactory report from Lloyd''''s class. Deficiency cleared.
Construction/Loadline › Structures
Issued 9 April 2002 Resolved
Deck plating underneath the fresh water generator is severely wasted and holed. 2ft by 3in hole through deck. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2002
Resolved 19 April 2002
Resolution: Received satisfactory report from Lloyds class. Deck plating renewed.
Engineering › Steering Gear System
Issued 9 April 2002 Resolved
Approx. 1/4 gal of hydraulic fluid is leaking from the shaft seal of the steering gear. LEGACY COMPONENT DESC: Ram Seal
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2002
Resolved 11 April 2002
Resolution: Received satisfactory class report attesting to repairs.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 9 April 2002 Resolved
Excessive fuel oil leak from fuel injector intake line on #3 cylinder of #3 generator. LEGACY COMPONENT DESC: Nozzle, Injection (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2002
Resolved 11 April 2002
Resolution: Received satisfactory class report.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 9 April 2002 Resolved
Lube oil leak from lube oil pump on #3 generator. LEGACY COMPONENT DESC: Pump, Positive Displacement
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2002
Resolved 11 April 2002
Resolution: Received staisfactory class report.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 9 April 2002 Resolved
Excessive jacket water leak from heat exchanger on #3 generator. LEGACY COMPONENT DESC: Charge Air Cooling
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2002
Resolved 19 April 2002
Resolution: Received report from class.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 9 April 2002 Resolved
Excessive jacket water leak from #6 cylinder of main engine. LEGACY COMPONENT DESC: Cylinder Head
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2002
Resolved 19 April 2002
Resolution: Received satisfactory report from Lloyd''''s class. Deficiency cleared.
Accommodation/Occupational Safety
Issued 17 August 2001 Resolved
Entire house including stores, habitation, food preparation, galley, and all passageways, had roach infestations.
Condition: Unknown
Due 20 August 2001
Resolved 20 August 2001
Fire Fighting
Issued 18 April 2000 Resolved
THE M/V AXION FIREMAIN PIPING AFT OF THE FOREPEAK IS LEAKING DUE TO IMPROPER PATCHING AS TO SOLAS 74 II-2/REG21. VESSEL IS TO PROVE PROPER OPERATION PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Navigation
Issued 15 October 1998 Resolved
Double nut all three steering gear actuator linkages. Or cotter key.
Condition: Unknown
Due 15 October 1998
Resolved 16 October 1998
Electrical
Issued 5 February 1998 Resolved
MISSING ELECTRICAL SAFETY MATTING IN ENG CONTROL ROOM AN IN EMERGENCY GEN ROOM._x001C_ _x001C_ SOLAS 60 REG II/27(a)_x001C_
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Navigation
Issued 26 August 1996 Resolved
Light list VOL VII not corrected.
Condition: Unknown
Due 30 August 1996
Resolved 30 August 1996
Navigation
Issued 26 August 1996 Resolved
MANEUVERING INFO FACT SHEET WAS MISSING NORMAL LOAD AND BALLAST INFO AS WELL AS THE WARNING STATEMENT.
Condition: Unknown
Due 30 August 1996
Resolved 30 August 1996
Navigation
Issued 26 August 1996 Resolved
Rudder angle indicator linkage is missing cotter pins on 3 bolts.
Condition: Unknown
Due 30 August 1996
Resolved 30 August 1996
Navigation
Issued 26 August 1996 Resolved
The following charts were not corrected. 14768, 14800, 14802, 14806, 14820,14822, 14826, 14839.
Condition: Unknown
Due 30 August 1996
Resolved 30 August 1996
Construction/Loadline
Issued 23 May 1996 Resolved
The vsl did not report that it was carrying ballst water on board. Vsl wasboarded for a B.W. Spot Chk which revealed 40 MT of ballst in the Aft Peak tank. The salinity was 40 PPT with the master not being able to provide proof of were the B.W. was taken on or that it was unpumpable.
Condition: Unknown
Due 12 February 1998
Resolved 12 February 1998
Navigation
Issued 6 December 1993 Resolved
U.S. COAST PILOT VOL 6, A REQUIRED PUB FOR TRANSITING THE GREAT LAKES, MISSING.
Condition: Unknown
Due 10 December 1993
Resolved 9 December 1993
Navigation
Issued 6 December 1993 Resolved
CHARTS 14768, 14802, 14882, 14968, REQUIRED CHARTS, WERE OUTDATED & NOT CURRENTLY CORRECTED._x001C_
Condition: Unknown
Due 10 December 1993
Resolved 9 December 1993
Navigation
Issued 6 December 1993 Resolved
COAST GUARD LIGHT LIST VOL 7, A REQUIRED PUB FOR TRANSITING THE GREAT LAKES, NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 10 December 1993
Resolved 9 December 1993
Navigation
Issued 28 April 1993 Resolved
33 CFR 164.33(a)(1)(ii). THE FOREIGN VESSEL LA FRENAIS WAS USING CHART 14905 THAT WAS NOT CURRENTLY CORRECTED. THE CHART NEEDED CORRECTIONS 43/92AND 45/92,FOR THE BURNS HARBOR AREA THAT THEY WERE TRANSITTING.
Condition: Unknown
Due 28 April 1993
Resolved 28 April 1993
Navigation
Issued 27 April 1992 Resolved
Vessel missing chart #14964.
Condition: Unknown
Due 28 April 1992
Resolved 29 April 1992
Navigation
Issued 5 August 1991 Resolved
MSO PERS BOARDED VESSEL AND FOUND MISSING COAST PILOT AND THE FOLLOWING CHARTS: 14806, 14862, 14882, 14883, 14962, 14964, 14967, 14975.
Condition: Unknown
Due 6 August 1991
Resolved 7 August 1991
Accommodation/Occupational Safety
Issued 22 April 1991 Resolved
VESSEL DID NOT HAVE A PLACARD ON THIER MSD AS REQUIRED BY(33 CFR 159.7)
Condition: Unknown
Due 23 September 1991
Resolved 23 September 1991
Navigation
Issued 22 April 1991 Resolved
PRE-ARRIVAL TESTS WERE NOT LOGGED AS REQUIRED BY 33 CFR 164.11(q))
Condition: Unknown
Due 23 September 1991
Resolved 23 September 1991
Unknown
Issued 13 January 1990 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 January 1990
Resolved 13 January 1990
Documentation
Issued 13 January 1990 Resolved
A VIOLATION OF 33CFR155.750 IN THAT THE OTP REQUIRED BY 33CFR155.720 AND FURTHER DESCRIBED BY REFERENCE TO 33CFR154.310 WERE INCOMPLETE IN THAT THEYDID NOT CONTAIN PROCEDURES FOR EMPTYING DISCHARGE CONTAINMENT.
Condition: Unknown
Due 13 January 1990
Resolved 13 January 1990
Documentation
Issued 13 January 1990 Resolved
A VIOLATION OF 33CFR155.750 IN THAT THE OTP REQUIRED BY 33CFR155.720 AND FURTHER DESCRIBED BY REFERENCE TO 33CFR155.785 WERE INCOMPLETE IN THAT THEYDID NOT CONTAIN PROCEDURES FOR, AND MEANS OF COMMUNICATION.
Condition: Unknown
Due 13 January 1990
Resolved 13 January 1990
Navigation
Issued 25 September 1987 Resolved
OUTDATED CHARTS #14963-14768-14820
Condition: Unknown
Due 25 September 1987
Resolved 25 September 1987
Navigation
Issued 25 September 1987 Resolved
COAST PILOT OUTDATED
Condition: Unknown
Due 25 September 1987
Resolved 25 September 1987
Documentation
Issued 25 October 1984 Resolved
VESSEL DID NOT HAVE A MARPOL OIL RECORD BOOK AS REQ BY 33 CFR 151.25.
Condition: Unknown
Due 25 October 1984
Resolved 25 October 1984
Documentation
Issued 25 October 1984 Resolved
VESSEL DID NOT HAVE ON BOARD WRITTEN OIL TRANSFER PROCEDURES AS REQ BY 33 CFR 155.750.
Condition: Unknown
Due 26 October 1984
Resolved 25 October 1984
Navigation
Issued 25 October 1984 Resolved
VESSEL DID NOT HAVE ON BOARD A COPY OF INLAND NAVRULS AS REQ BY 33 CFR 88.05.
Condition: Unknown
Due 26 October 1984
Resolved 25 October 1984
Navigation
Issued 25 October 1984 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 26 October 1984
Resolved 25 October 1984
Navigation
Issued 25 October 1984 Resolved
THE FOLLOWING CHARTS WERE REQUIRED FOR THIS VESSELS GREAT LAKES VOYAGE. CHARTS WERE ON BOARD BUT NOT CURRENTLY CORRECTED AS REQ BY 33 CFR 164.33 (A) (1): 14830, 14848, 14850, 14854, 14860, 14900, 14902, 14905, 14913, AND 14929.
Condition: Unknown
Due 26 October 1984
Resolved 25 October 1984
Navigation
Issued 25 October 1984 Resolved
VSL OVER 10,000 GT, TWO RADARS REQUIRED. ONE RADAR INOPERATIVE. REPAIRS ORDERED FOR DETROIT PORT CALL.
Condition: Unknown
Due 26 October 1984
Resolved 25 October 1984

Ownership record