MAURY USCG vessel records Sign in
← All vessels

ROSARIO DEL MAR

ROSARIO DEL MAR is a 1977 tank ship. The Coast Guard has recorded 17 inspections since 1984, most recently in June 1993, along with 6 deficiencies.

Records from 1984 to 1993. Most recent: inspection, 30 June 1993.

Built
1977
Last inspected
30 June 1993
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7402568 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224970
Flag
PORTUGAL
—
Maury page id
psix-224970

Inspections, by type

…with no type recorded12
Years with a record 8 calendar years (1984–1993)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 33 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it50165 - Regulatory (Subpart C or D), Net Ton
66596 - Regulatory (Subpart C or D), Gross Ton
132201 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 17

30 June 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 359695
25 June 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 359356
25 June 1993 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1434018
17 May 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 444181
9 October 1991 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1246762
5 October 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 346579
5 October 1991 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 941361
28 December 1989 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 444585
6 July 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 331308
17 August 1987 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 317920
17 August 1987 Certificate of Compliance · MARPOL Annex II Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1033404
5 May 1987 Administrative
Administrative · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1329329
9 December 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 313134
19 June 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 309829
27 March 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 301009
25 July 1984 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 438083
25 July 1984 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 499021

Deficiency record · 6

Electrical
Issued 25 June 1993 Resolved
REPLACE OR RENEW BATTERIES FOR VESSELS EMERGENCY DIESEL AND TEST PROPER OPERATION OF DIESEL GENERATOR PRIOR TO ENTRY ENTO US PORT. LOG SAME AS REQUIRED UNDER PRE-ARRIVAL CHECKES IN 33CFR164.
Condition: Unknown
Due 2 July 1993
Resolved 2 July 1993
Deck/Cargo
Issued 5 October 1991 Resolved
NO CARGO IS TO BE TRANSERRED (INTERNALLY INCLUDED) UNTIL SUCH TIME AS THE PUMP ROOM IS INSPECTED AND ACCEPTED AS SAFE BY A U.S. COAST GUARD INSPECTORVESSEL SHALL NOT ENTER U.S. WATERS UNTIL SUCH TIME AS THE ABOVE IS CORRECTED.
Condition: Unknown
Due 5 November 1991
Resolved 17 October 1991
Fire Fighting
Issued 5 October 1991 Resolved
MAKE NECESSARY REPAIRS AND PROVE PROPER OPERATION OF THE EMERGENCY FIRE PUMP.
Condition: Unknown
Due 4 November 1991
Resolved 17 October 1991
Navigation
Issued 5 October 1991 Resolved
REPAIR HYDRAULIC LEAKS LOCATED ON STEERING RAMS.
Condition: Unknown
Due 17 October 1991
Resolved 17 October 1991
Fire Fighting
Issued 19 June 1986 Resolved
PRIOR TO NEXT U.S. PORT, MUST HAVE DUPLICATE SET OF FIRE CONTROL PLANS IN ACCORDANCE WITH SOLAS 1974, REGULATION 20, CHAPTER II-2. THIS IS A SOLAS AMMENDMENT ADOPTED ON 20 NOV. 1981
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Deck/Cargo
Issued 27 March 1985 Resolved
MAKE PERMANENT REPAIRS OR REPLACE ALL FLAME SCREENS ON P/V VENTS PRIOR TO NEXT U.S. PORT OF CALL. 46 CFR 35.30-10
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.