FORMOSA TRIDENT
FORMOSA TRIDENT is a 1978 freight ship. The Coast Guard has recorded 26 inspections since 1984, most recently in April 2004, along with 55 deficiencies and 4 operational controls.
Records from 1984 to 2004. Most recent: inspection, 23 April 2004.
- Built
- 1978
- Last inspected
- 23 April 2004
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 55 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7403225 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
H9WY
224980
Flag
PANAMA
—
Maury page id
psix-224980
Inspections, by type
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it26954 - Convention (Subpart B), Net Ton
46178 - Convention (Subpart B), Gross Ton
81776 - Dead Weight, Ton
98559 - Displacement, Ton
46178 - Convention (Subpart B), Gross Ton
81776 - Dead Weight, Ton
98559 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
23 April 2004
Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2051098
16 March 2004
Deficiency Check · Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2025953
12 March 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2024444
10 March 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2023060
10 March 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2025826
7 June 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 278550
5 April 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 276285
14 August 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 431559
7 March 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 426359
25 February 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 412517
11 June 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 404539
24 October 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 718303
7 October 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 128102
28 May 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 391621
13 May 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 378132
9 June 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 367487
12 December 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 487420
18 March 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 498507
19 November 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 538812
7 August 1992
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 352293
7 November 1991
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 346890
30 August 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 339031
29 September 1988
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 325832
15 September 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 318340
16 November 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 305187
17 August 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 443920
Deficiency record · 55
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 12 April 2004
Resolved
The RPM indicator for the main engine in the engine control room is not functioning properly. It indicates speed but not proper direction of the engine. The engine can only be controlled from local station which is manned at all times during maneuvering.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 12 April 2004
Resolved
The No. 2 generator has a noteworthy fuel leak from the #2 fuel pump.
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 12 April 2004
Resolved
The No. 3 generator has cooling water leaking from numerous cylinder heads.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 5 April 2004
Resolved
The main engine has water in the lube oil. Remove water from oil and prove proper operation of main engine lubricating system to the satisfaction of classification society and prepare main engine for testing to the satisfaction of CG marine inspector prior to departure from Harmony Street.
Electrical › Electric Generation Source (service) › Generator
Issued 5 April 2004
Resolved
The vessel has installed temporary generator on the outside upper deck and connected it to the main switchboard of in place of the No. 1 generator. Remove generator or provide class attestation that the arrangement is acceptable to operate while maneuvering prior to departure from Harmony Street.
LEGACY COMPONENT DESC: Generator
Engineering › Bilge Water Management System › Not Operational
Issued 5 April 2004
Resolved
The vessel has an excessive amount of water and oil in bilge. Remove all oil and water and provide invoice of proper disposal to USCG.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 1 April 2004
Resolved
On two separate occasions the master and C/E could not demonstrate the emergency steering drill following the posted instructions.
LEGACY COMPONENT DESC: Emergency Preparedness
Operations/Management › Vessel Safety Management
Issued 1 April 2004
Resolved
On two separate occasions the vessel's crew placed a wooden wedge into the remote operated emergency shutdown valve of the diesel oil service tank, rendering it inoperable.
LEGACY COMPONENT DESC: Emergency Preparedness
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 1 April 2004
Resolved
Objective evidence was found that the SMS has failed in the area of emergency preparedness. An external audit of the vessel's Safety Management System is requested to be carried out by the flag State or recognized organization acting on their behalf and the results sent to the Captain of the Port.
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 1 April 2004
Resolved
The No. 3 generator's jacket water pump is leaking excessively from the shaft seal.
Engineering › Diesel Engine (auxiliary)
Issued 1 April 2004
Resolved
The No. 3 generator has fuel leaks on the #2 and 4 cylinders.
LEGACY COMPONENT DESC: Injector (fuel injection)
Engineering › Compressed Air System (start air) › Compressor
Issued 1 April 2004
Resolved
Demonstrate proper operation of newly installed start air compressors.
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 16 March 2004
Resolved
The M/E jacket water piping to cylinder heads 1, 4, 5 and 6 are holed and leaking. Additionally, there is a temporary band clamp patch on the No. 6 cylinder. Permanently repair to the satisfaction of class.
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 16 March 2004
Resolved
The No. 1 jacket water cooler to the M/E is leaking jacket water excessively from the plates. Permanently repair to the satisfaction of class.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 16 March 2004
Resolved
The M/E No. 7 cylinder second stage inlet air cooler is missing. Replace or provide class attestation to this arrangement.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 16 March 2004
Resolved
The No. 2 generator has excessive fuel oil leaks from the injection nozzle drain of the No. 1 and 8 cylinders. Repair to the satisfaction of class prior to operation in U.S. waters.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 16 March 2004
Resolved
The No. 2 generator has excessive fuel oil leak on the injection nozzle fitting of the No. 4 cylinder. Repair to the satisfaction of class prior to operation in U.S. waters.
Engineering › Lubricating Oil Service System › Cooler
Issued 16 March 2004
Resolved
The No. 2 generator has excessive lube oil leak from the lube oil cooler piping on the front of the engine that is draining into a catch bucket. Repair to the satisfaction of class prior to operation in U.S. waters.
Engineering › Diesel Engine (auxiliary) › Crankshaft
Issued 16 March 2004
Resolved
The No. 3 generator has excessive lube oil leak from the forward crankshaft seal on the front of the engine that is draining into a catch bucket. Repair to the satisfaction of class prior to operation in U.S. waters.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 16 March 2004
Resolved
The No. 3 generator has excessive fuel oil leak on the injection nozzle fittings of the No. 7 and 8 cylinders. Repair to the satisfaction of class prior to operation in U.S. waters.
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 16 March 2004
Resolved
The No. 1 generator has excessive cooling water leaks on numerous cylinder heads. Repair to the satisfaction of class.
Engineering › Diesel Engine (auxiliary) › Nozzle, Injection (fuel injection)
Issued 16 March 2004
Resolved
The No. 1 generator has fuel oil leak on the injection nozzle fitting of no. 6 cylinder. Repair to the satisfaction of class.
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 March 2004
Resolved
The main cooling water line to the generator jacket water coolers has two cement boxes located forward of the No. 3 generator under the deck plates. Permanently repair to the satisfaction of class.
Engineering › Bilge Water Management System › Not Operational
Issued 16 March 2004
Resolved
The containment under the generators is full with oil and water. Remove all oil and wipe dry to the satisfaction of class.
Engineering › Sea-water System (primary cooling) › Pump
Issued 16 March 2004
Resolved
The No. 1 salt water cooling pump to the generators is missing. Replace and prove proper operation to the satisfaction of class.
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 March 2004
Resolved
The M/E sea water cooling line to the piston cooler has a temporary band clamp patch. Permanently repair to the satisfaction of class.
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 March 2004
Resolved
The M/E sea water cooling pump No. 2 has a temporary band clamp patch on the outlet piping. Permanently repair to the satisfaction of class. LEGACY COMPONENT DESC: Piping
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 16 March 2004
Resolved
The No. 1 generator's high pressure fuel line double jacketed piping is cracked or open in several places and needs to be replaced. Replace all defective piping.
Engineering › Bilge Water Management System › Not Operational
Issued 16 March 2004
Resolved
The engine room bilges and the bilge holding tank are full of oil and water. Remove all oil and water from bilges and provide sufficient space in bilge holding tank to maintain the bilges in a clean and dry manner.
Engineering › Steering Gear System › Pump
Issued 16 March 2004
Resolved
The No.2 steering pump has a steady stream hydraulic oil leak at the shaft seal after every movement. Repair to satisfaction of class.
Engineering › Steering Gear System › Piping
Issued 16 March 2004
Resolved
Numerous minor lube oil leaks throughout the steering gear hydraulic system. Repair all leaks and wipe up standing oil in steering containment to satisfaction of class.
Engineering › Steering Gear System › Motor
Issued 16 March 2004
Resolved
The No. 2 steering pump motor electrical connections are loose and not sealed properly. Tighten the connections and reseal to the satisfaction of class.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 March 2004
Resolved
The light fixture located on the forward section of the starboard bulkhead in steering room is broken and the wires are exposed. Repair light or properly dead end the wires to satisfaction of class.
Deck/Cargo › Ballast › Piping
Issued 16 March 2004
Resolved
The starboard ballast overboard piping has a temporary band clamp patch. Repair to the satisfaction of class.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 16 March 2004
Resolved
A hole was cut into the after bulkhead of the boiler space to allow a rubber hose connected to the forward upper bulkhead of the boiler space to connect to drain piping in the aft passageway leading to the fantail. Remove hose and repair hole to the satisfaction of class.
LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 16 March 2004
Resolved
All three generator grounding straps were broken and several electrical motor grounding straps were missing or disconnected. Connect and or replace all electrical grounding straps to the satisfaction of class.
Engineering › Compressed Air System (start air) › Compressor
Issued 16 March 2004
Resolved
The main and auxiliary air compressors do not work and a temporary air compressor has been installed on the starboard aft deck. Provide one engineer with radio communication to standby temporary air compressor during all maneuvering operations within the Mississippi River.
LEGACY COMPONENT DESC: Compressor
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 16 March 2004
Resolved
The master and C/E are unaware of the emergency steering instructions step to switch to AUX NFU. Prove proper emergency steering operation in accordance with the posted instructions prior to departure.
LEGACY COMPONENT DESC: Drill Procedures
Personnel › Training › Familiarization Training
Issued 16 March 2004
Resolved
The C/E and the 1/E could not produce a record of crew familiarization upon arrival. Provide documents of familiarization.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 16 March 2004
Resolved
The starboard anchor windlass controller was temporarily repaired with non standard parts. Provide proper electrical components and prove proper operation to the satisfaction of class.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 16 March 2004
Resolved
Main engine jacket water cooling return line on the #3 and #6 cylinders are leaking. Make permanent repair.
Navigation
Issued 5 April 2000
Resolved
HYDRAULIC OIL OVERFLOW FROM STEERING GEAR HEAD TANK IS COLLECTED IN SMALL CAN AND CREW IS ABLE TO RETURN THAT OIL BACK TO HEAD TANK.
Accommodation/Occupational Safety
Issued 7 March 1999
Resolved
MAKE PERMANENT REPAIR TO THE REFRIGERATION COOLING PIPE ON THE LOWER LEVEL OF ENGINE ROOM.
Navigation
Issued 7 March 1999
Resolved
REPAIR LEAKING STEERING PUMP SEALS IAW SOLAS 60 II/29.
Construction/Loadline
Issued 7 March 1999
Resolved
MAKE PERMANENT REPAIR TO LEAKING WELD IN 20 INCH BALLAST LINE ON PORTSIDE LOWER ENGINE ROOM.
Engineering
Issued 7 March 1999
Resolved
REPAIR OR REPLACE LEAKING STEAM VALVE IN FUEL HEATING LINE LACOATED IN THE LOWER MACHINERY SPACE LEVEL, STARBOARD SIDE, FORWARD OF THE MAIN ENGINE.
Fire Fighting
Issued 7 March 1999
Resolved
PROVE PROPER OPERATION OF THE EMERGENCY FIRE PUMP.
Navigation
Issued 11 June 1997
Resolved
Excessive oil around emergency steering causing a slip hazard. Corrected 12 June 1997.
Deck/Cargo
Issued 11 June 1997
Resolved
Buckled Corner radius with fracture at hold #1 starboard side aft. Corrected 12 June 1997 per class recommendations.
Construction/Loadline
Issued 11 June 1997
Resolved
Cement box patch in engine room on ballast pump discharge flange, port side. Corrected 12 June 1997 per class recommendations.
Lifesaving
Issued 11 June 1997
Resolved
Port and starboard lifeboat flotation chambers fractured through to styrofoam inserts. Corrected 12 June 1997 per class recommendations.
Lifesaving
Issued 11 June 1997
Resolved
4 kg lifebuoys missing from quick-release station on port and starboard wing bridges. Corrected 12 June 1997.
Documentation
Issued 30 August 1990
Resolved
A vio of 33CFR155.820 in that the vessel did not have a written record of the date and results of the most recent test of the oil transfer system as req by 33CFR156.170._x001C_ _x001C_
Navigation
Issued 29 September 1988
Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT THE USCG LIGHT LIST (VOL.2) USED BY THE VSL WAS NOT CORRECTED UP THRU NTM 17/88, WHICH WERE REASONABLY AVAIL AND CONTAINED CORR APP TO THE VSLS ROUTE FROM SMITH PT VA TO BALT HBR.
Navigation
Issued 16 November 1985
Resolved
A VIO OF 33 CFR 164.30 IN THAT A COMPLETE SET OF CURRENTLY CORRECTED U.S. CHARTS OR THEIR EQUIV OF THE AREA TRANSITED, AS REQ BY 33 CFR 164.33(A)(1) (II) WAS NOT O/B. THE VSL HAD O/B U.S. CHARTS #12221 DTD 1984 WITH NO COR- RECTIONS, AND #12222 AND #12245 BOTH CORRECTED TO 32/84.