MAURY USCG vessel records Sign in
← All vessels

FORMOSA TRIDENT

FORMOSA TRIDENT is a 1978 freight ship. The Coast Guard has recorded 26 inspections since 1984, most recently in April 2004, along with 55 deficiencies and 4 operational controls.

Records from 1984 to 2004. Most recent: inspection, 23 April 2004.

Built
1978
Last inspected
23 April 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7403225 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224980
Flag
PANAMA
—
Maury page id
psix-224980

Inspections, by type

…with no type recorded24
Years with a record 16 calendar years (1984–2004)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it26954 - Convention (Subpart B), Net Ton
46178 - Convention (Subpart B), Gross Ton
81776 - Dead Weight, Ton
98559 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

23 April 2004 Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2051098
16 March 2004 Deficiency Check · Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2025953
12 March 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2024444
10 March 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2023060
10 March 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2025826
7 June 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 278550
5 April 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 276285
14 August 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 431559
7 March 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 426359
25 February 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 412517
11 June 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 404539
24 October 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 718303
7 October 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 128102
28 May 1996 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 391621
13 May 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 378132
9 June 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 367487
12 December 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 487420
18 March 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 498507
19 November 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 538812
7 August 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 352293
7 November 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 346890
30 August 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 339031
29 September 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 325832
15 September 1987 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 318340
16 November 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 305187
17 August 1984 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 443920

Deficiency record · 55

Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 12 April 2004 Resolved
The RPM indicator for the main engine in the engine control room is not functioning properly. It indicates speed but not proper direction of the engine. The engine can only be controlled from local station which is manned at all times during maneuvering.
Action required: 705 - Other - as specified
Due 15 April 2004
Resolved 23 April 2004
Resolution: Received class report satisfying requirement.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 12 April 2004 Resolved
The No. 2 generator has a noteworthy fuel leak from the #2 fuel pump.
Action required: 705 - Other - as specified
Due 15 April 2004
Resolved 23 April 2004
Resolution: Received class report satisfying requirement.
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 12 April 2004 Resolved
The No. 3 generator has cooling water leaking from numerous cylinder heads.
Action required: 705 - Other - as specified
Due 15 April 2004
Resolved 23 April 2004
Resolution: Received class report satisfying requirement.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 5 April 2004 Resolved
The main engine has water in the lube oil. Remove water from oil and prove proper operation of main engine lubricating system to the satisfaction of classification society and prepare main engine for testing to the satisfaction of CG marine inspector prior to departure from Harmony Street.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2004
Resolved 12 April 2004
Resolution: Verified deficiency cleared during follow-up inspection.
Electrical › Electric Generation Source (service) › Generator
Issued 5 April 2004 Resolved
The vessel has installed temporary generator on the outside upper deck and connected it to the main switchboard of in place of the No. 1 generator. Remove generator or provide class attestation that the arrangement is acceptable to operate while maneuvering prior to departure from Harmony Street. LEGACY COMPONENT DESC: Generator
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2004
Resolved 12 April 2004
Resolution: Verified deficiency cleared during follow-up inspection.
Engineering › Bilge Water Management System › Not Operational
Issued 5 April 2004 Resolved
The vessel has an excessive amount of water and oil in bilge. Remove all oil and water and provide invoice of proper disposal to USCG.
Action required: 705 - Other - as specified
Due 5 April 2004
Resolved 12 April 2004
Resolution: Verified deficiency cleared during follow-up inspection and viewed invoice for slops removal.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 1 April 2004 Resolved
On two separate occasions the master and C/E could not demonstrate the emergency steering drill following the posted instructions. LEGACY COMPONENT DESC: Emergency Preparedness
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 12 April 2004
Resolution: Verified deficiency cleared during follow-up inspection.
Operations/Management › Vessel Safety Management
Issued 1 April 2004 Resolved
On two separate occasions the vessel's crew placed a wooden wedge into the remote operated emergency shutdown valve of the diesel oil service tank, rendering it inoperable. LEGACY COMPONENT DESC: Emergency Preparedness
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 12 April 2004
Resolution: Verified deficiency cleared during follow-up inspection.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 1 April 2004 Resolved
Objective evidence was found that the SMS has failed in the area of emergency preparedness. An external audit of the vessel's Safety Management System is requested to be carried out by the flag State or recognized organization acting on their behalf and the results sent to the Captain of the Port.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2004
Resolved 9 April 2004
Resolution: Received copy of external audit by the flag state.
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 1 April 2004 Resolved
The No. 3 generator's jacket water pump is leaking excessively from the shaft seal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 12 April 2004
Resolution: Verified deficiency cleared during follow-up inspection.
Engineering › Diesel Engine (auxiliary)
Issued 1 April 2004 Resolved
The No. 3 generator has fuel leaks on the #2 and 4 cylinders. LEGACY COMPONENT DESC: Injector (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 12 April 2004
Resolution: Verified deficiency cleared during follow-up inspection.
Engineering › Compressed Air System (start air) › Compressor
Issued 1 April 2004 Resolved
Demonstrate proper operation of newly installed start air compressors.
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 12 April 2004
Resolution: Verified deficiency cleared during follow-up inspection.
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 16 March 2004 Resolved
The M/E jacket water piping to cylinder heads 1, 4, 5 and 6 are holed and leaking. Additionally, there is a temporary band clamp patch on the No. 6 cylinder. Permanently repair to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 16 March 2004 Resolved
The No. 1 jacket water cooler to the M/E is leaking jacket water excessively from the plates. Permanently repair to the satisfaction of class.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 16 March 2004 Resolved
The M/E No. 7 cylinder second stage inlet air cooler is missing. Replace or provide class attestation to this arrangement.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report stating the air cooler has been installed.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 16 March 2004 Resolved
The No. 2 generator has excessive fuel oil leaks from the injection nozzle drain of the No. 1 and 8 cylinders. Repair to the satisfaction of class prior to operation in U.S. waters.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 16 March 2004 Resolved
The No. 2 generator has excessive fuel oil leak on the injection nozzle fitting of the No. 4 cylinder. Repair to the satisfaction of class prior to operation in U.S. waters.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Engineering › Lubricating Oil Service System › Cooler
Issued 16 March 2004 Resolved
The No. 2 generator has excessive lube oil leak from the lube oil cooler piping on the front of the engine that is draining into a catch bucket. Repair to the satisfaction of class prior to operation in U.S. waters.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Engineering › Diesel Engine (auxiliary) › Crankshaft
Issued 16 March 2004 Resolved
The No. 3 generator has excessive lube oil leak from the forward crankshaft seal on the front of the engine that is draining into a catch bucket. Repair to the satisfaction of class prior to operation in U.S. waters.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 16 March 2004 Resolved
The No. 3 generator has excessive fuel oil leak on the injection nozzle fittings of the No. 7 and 8 cylinders. Repair to the satisfaction of class prior to operation in U.S. waters.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 16 March 2004 Resolved
The No. 1 generator has excessive cooling water leaks on numerous cylinder heads. Repair to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 23 April 2004
Resolution: Received class report satisfying requirement.
Engineering › Diesel Engine (auxiliary) › Nozzle, Injection (fuel injection)
Issued 16 March 2004 Resolved
The No. 1 generator has fuel oil leak on the injection nozzle fitting of no. 6 cylinder. Repair to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 12 April 2004
Resolution: Verified deficiency cleared during follow-up inspection.
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 March 2004 Resolved
The main cooling water line to the generator jacket water coolers has two cement boxes located forward of the No. 3 generator under the deck plates. Permanently repair to the satisfaction of class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Engineering › Bilge Water Management System › Not Operational
Issued 16 March 2004 Resolved
The containment under the generators is full with oil and water. Remove all oil and wipe dry to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Engineering › Sea-water System (primary cooling) › Pump
Issued 16 March 2004 Resolved
The No. 1 salt water cooling pump to the generators is missing. Replace and prove proper operation to the satisfaction of class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 March 2004 Resolved
The M/E sea water cooling line to the piston cooler has a temporary band clamp patch. Permanently repair to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 March 2004 Resolved
The M/E sea water cooling pump No. 2 has a temporary band clamp patch on the outlet piping. Permanently repair to the satisfaction of class. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 12 April 2004
Resolution: A condition of class was issued allowing for permanent repair at next dry-dock but not later than 30JUN04.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 16 March 2004 Resolved
The No. 1 generator's high pressure fuel line double jacketed piping is cracked or open in several places and needs to be replaced. Replace all defective piping.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 12 April 2004
Resolution: Verified deficiency cleared during follow-up inspection.
Engineering › Bilge Water Management System › Not Operational
Issued 16 March 2004 Resolved
The engine room bilges and the bilge holding tank are full of oil and water. Remove all oil and water from bilges and provide sufficient space in bilge holding tank to maintain the bilges in a clean and dry manner.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Engineering › Steering Gear System › Pump
Issued 16 March 2004 Resolved
The No.2 steering pump has a steady stream hydraulic oil leak at the shaft seal after every movement. Repair to satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Engineering › Steering Gear System › Piping
Issued 16 March 2004 Resolved
Numerous minor lube oil leaks throughout the steering gear hydraulic system. Repair all leaks and wipe up standing oil in steering containment to satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Engineering › Steering Gear System › Motor
Issued 16 March 2004 Resolved
The No. 2 steering pump motor electrical connections are loose and not sealed properly. Tighten the connections and reseal to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 March 2004 Resolved
The light fixture located on the forward section of the starboard bulkhead in steering room is broken and the wires are exposed. Repair light or properly dead end the wires to satisfaction of class.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 12 April 2004
Resolution: Verified during deficiency follow-up.
Deck/Cargo › Ballast › Piping
Issued 16 March 2004 Resolved
The starboard ballast overboard piping has a temporary band clamp patch. Repair to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 12 April 2004
Resolution: A condition of class was issued for permanent repair at next dry-dock but not later then 30JUN04.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 16 March 2004 Resolved
A hole was cut into the after bulkhead of the boiler space to allow a rubber hose connected to the forward upper bulkhead of the boiler space to connect to drain piping in the aft passageway leading to the fantail. Remove hose and repair hole to the satisfaction of class. LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 16 March 2004 Resolved
All three generator grounding straps were broken and several electrical motor grounding straps were missing or disconnected. Connect and or replace all electrical grounding straps to the satisfaction of class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report.
Engineering › Compressed Air System (start air) › Compressor
Issued 16 March 2004 Resolved
The main and auxiliary air compressors do not work and a temporary air compressor has been installed on the starboard aft deck. Provide one engineer with radio communication to standby temporary air compressor during all maneuvering operations within the Mississippi River. LEGACY COMPONENT DESC: Compressor
Condition: Damaged By Earlier Event
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory class report. Upon boarding for deficiency follow-up it was found that the automatic shutdown devices for over pressurization had not been installed. A requirement was issued to prove proper operation prior to movement.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 16 March 2004 Resolved
The master and C/E are unaware of the emergency steering instructions step to switch to AUX NFU. Prove proper emergency steering operation in accordance with the posted instructions prior to departure. LEGACY COMPONENT DESC: Drill Procedures
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 March 2004
Resolved 12 April 2004
Resolution: Verified deficiency cleared during follow-up inspection.
Personnel › Training › Familiarization Training
Issued 16 March 2004 Resolved
The C/E and the 1/E could not produce a record of crew familiarization upon arrival. Provide documents of familiarization.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Received satisfactory documentation during follow-up inspection.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 16 March 2004 Resolved
The starboard anchor windlass controller was temporarily repaired with non standard parts. Provide proper electrical components and prove proper operation to the satisfaction of class.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 16 March 2004
Resolved 1 April 2004
Resolution: Verified repair during deficiency follow-up exam.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 16 March 2004 Resolved
Main engine jacket water cooling return line on the #3 and #6 cylinders are leaking. Make permanent repair.
Action required: 705 - Other - as specified
Due 12 April 2004
Resolved 12 April 2004
Resolution: Verified repairs made prior to completion of inspection.
Navigation
Issued 5 April 2000 Resolved
HYDRAULIC OIL OVERFLOW FROM STEERING GEAR HEAD TANK IS COLLECTED IN SMALL CAN AND CREW IS ABLE TO RETURN THAT OIL BACK TO HEAD TANK.
Condition: Unknown
Due 7 June 2000
Resolved 7 June 2000
Accommodation/Occupational Safety
Issued 7 March 1999 Resolved
MAKE PERMANENT REPAIR TO THE REFRIGERATION COOLING PIPE ON THE LOWER LEVEL OF ENGINE ROOM.
Condition: Unknown
Due 15 August 1999
Resolved 15 August 1999
Navigation
Issued 7 March 1999 Resolved
REPAIR LEAKING STEERING PUMP SEALS IAW SOLAS 60 II/29.
Condition: Unknown
Due 15 August 1999
Resolved 15 August 1999
Construction/Loadline
Issued 7 March 1999 Resolved
MAKE PERMANENT REPAIR TO LEAKING WELD IN 20 INCH BALLAST LINE ON PORTSIDE LOWER ENGINE ROOM.
Condition: Unknown
Due 15 August 1999
Resolved 15 August 1999
Engineering
Issued 7 March 1999 Resolved
REPAIR OR REPLACE LEAKING STEAM VALVE IN FUEL HEATING LINE LACOATED IN THE LOWER MACHINERY SPACE LEVEL, STARBOARD SIDE, FORWARD OF THE MAIN ENGINE.
Condition: Unknown
Due 15 August 1999
Resolved 15 August 1999
Fire Fighting
Issued 7 March 1999 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY FIRE PUMP.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Navigation
Issued 11 June 1997 Resolved
Excessive oil around emergency steering causing a slip hazard. Corrected 12 June 1997.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Deck/Cargo
Issued 11 June 1997 Resolved
Buckled Corner radius with fracture at hold #1 starboard side aft. Corrected 12 June 1997 per class recommendations.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Construction/Loadline
Issued 11 June 1997 Resolved
Cement box patch in engine room on ballast pump discharge flange, port side. Corrected 12 June 1997 per class recommendations.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Lifesaving
Issued 11 June 1997 Resolved
Port and starboard lifeboat flotation chambers fractured through to styrofoam inserts. Corrected 12 June 1997 per class recommendations.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Lifesaving
Issued 11 June 1997 Resolved
4 kg lifebuoys missing from quick-release station on port and starboard wing bridges. Corrected 12 June 1997.
Condition: Unknown
Due 12 June 1997
Resolved 12 June 1997
Documentation
Issued 30 August 1990 Resolved
A vio of 33CFR155.820 in that the vessel did not have a written record of the date and results of the most recent test of the oil transfer system as req by 33CFR156.170._x001C_ _x001C_
Condition: Unknown
Due 15 December 1993
Resolved 15 December 1993
Navigation
Issued 29 September 1988 Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT THE USCG LIGHT LIST (VOL.2) USED BY THE VSL WAS NOT CORRECTED UP THRU NTM 17/88, WHICH WERE REASONABLY AVAIL AND CONTAINED CORR APP TO THE VSLS ROUTE FROM SMITH PT VA TO BALT HBR.
Condition: Unknown
Due 15 December 1993
Resolved 15 December 1993
Navigation
Issued 16 November 1985 Resolved
A VIO OF 33 CFR 164.30 IN THAT A COMPLETE SET OF CURRENTLY CORRECTED U.S. CHARTS OR THEIR EQUIV OF THE AREA TRANSITED, AS REQ BY 33 CFR 164.33(A)(1) (II) WAS NOT O/B. THE VSL HAD O/B U.S. CHARTS #12221 DTD 1984 WITH NO COR- RECTIONS, AND #12222 AND #12245 BOTH CORRECTED TO 32/84.
Condition: Unknown
Due 16 November 1985
Resolved 16 November 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.