MAURY USCG vessel records Sign in
← All vessels

ARGONISI

ARGONISI is a 1977 tank ship. The Coast Guard has recorded 28 inspections since 1984, most recently in April 1998, along with 18 deficiencies — 3 with no resolution recorded —.

Records from 1984 to 1998. Most recent: inspection, 1 April 1998.

Built
1977
Last inspected
1 April 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7403251 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224982
Flag
LIBERIA
—
Maury page id
psix-224982

Inspections, by type

…with no type recorded17
…past their stated due date3
Years with a record 13 calendar years (1984–1998)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12837 - Regulatory (Subpart C or D), Net Ton
19849 - Regulatory (Subpart C or D), Gross Ton
36313 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 28

1 April 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 414274
1 April 1998 Tank Vessel Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 787044
26 April 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 390648
2 May 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 377860
2 May 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 865634
20 December 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 373489
20 December 1994 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1380126
29 October 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 355005
13 July 1992 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1262403
8 June 1991 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318808
29 August 1990 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1228538
22 June 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 337621
10 March 1990 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1242134
5 August 1989 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 514960
15 January 1989 Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 887243
14 January 1989 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 327878
24 August 1988 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 513762
19 December 1987 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 320321
19 December 1987 Certificate of Compliance
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1007924
16 November 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 500519
19 March 1986 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 307661
19 March 1986 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1301347
15 March 1986 Damage Survey
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 989226
15 February 1986 Damage Survey
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1296572
17 January 1986 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 461140
4 August 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 466673
19 March 1985 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 300955
5 December 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 486545

Deficiency record · 18

Deck/Cargo
Issued 1 April 1998 No resolution recorded
Repair broken weld at base of hand grab post at top of large center line bulkhead in #2 center ballast tank. Presently one of two welds at base of post broken. Repair NLT 31 Jan 99 (next drydock).
Condition: Unknown
Due 31 January 1999 — due date passed with no resolution recorded
Lifesaving
Issued 1 April 1998 Resolved
Starboard lifeboat limit switch disattached from davit (broken weld). Repair NLT 01May98 with class attesting to repairs & proper operation of the limit switch.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Fire Fighting
Issued 1 April 1998 No resolution recorded
Renew support brackets at base of forward fire monitor NLT 31Jan99 (next drydock).
Condition: Unknown
Due 31 January 1999 — due date passed with no resolution recorded
Lifesaving
Issued 1 April 1998 Resolved
Port lifeboat has some disattached fiberglass inside IWO gunwhale. Starboard lifeboat appears to have had some repairs with fiberglass in_x001C_ same areas as in port lifeboat. Repairs to port lifeboat to be effected NLT 01May98 with class attesting to repairs of both lifeboats.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Engineering
Issued 1 April 1998 No resolution recorded
Renew broken steam line deck support brackets starboard side midships area NLT 31 Jan 99 (next drydock).
Condition: Unknown
Due 31 January 1999 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 2 May 1995 Resolved
Do not discharge sewage within U.S. territorial seas until proper chemicalsfor use with type II MSD are onbd.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Accommodation/Occupational Safety
Issued 20 December 1994 Resolved
LIVE BIRDS (PARROTS) KEPT IN DAILY DRY STORAGE ROOM IN GALLEY._x001C_ ILO 147_x001C_
Condition: Unknown
Due 20 December 1994
Resolved 29 December 1994
Accommodation/Occupational Safety
Issued 20 December 1994 Resolved
POSSIBLE DISPOSAL OF PLASTICS AT SEA._x001C_ LAST DISPOSAL OF PLASTICS ASHORE WAS 26OCT94. CREW=27, PLASTIC GARBAGE ON BOARD NOW, 3/4 OF 55 GALLON DRUM. DRY AND COLD STORES CONTAINED PLASTICS. see psns.
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Documentation
Issued 20 December 1994 Resolved
IMPROPER ENTREES IN OIL RECORD BOOK. (D)15.1 (THROUGH 100PPM EQUIP) USED INSTEAD OF (D)15.2 (THROUGH 15PPM EQUIP).
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Deck/Cargo
Issued 20 December 1994 Resolved
Prove effective operation of cargo pump remote shutdowns located in cargo control room prior to handling cargo in next U.S. port.
Condition: Unknown
Due 20 December 1994
Resolved 20 December 1994
Fire Fighting
Issued 20 December 1994 Resolved
Remove all non-remote controlled latches to firescreen doors on aft stairways and main stairtower by next U.S. port call.
Condition: Unknown
Due 20 December 1994
Resolved 20 December 1994
Fire Fighting
Issued 20 December 1994 Resolved
Repair firescreen door closing latch on stairtower at deck C by next U.S. port call.
Condition: Unknown
Due 20 December 1994
Resolved 20 December 1994
Lifesaving
Issued 20 December 1994 Resolved
Ensure port and stbd liferafts have proper weak links correctly installed prior to departure from Guayanilla, Puerto Rico.
Condition: Unknown
Due 20 December 1994
Resolved 23 December 1994
Deck/Cargo
Issued 20 December 1994 Resolved
Remove all cement patches from main deck scuppers and replace with mechanical closures as required by 33 CFR 155.310(a)(3) by next U.S. port call.
Condition: Unknown
Due 20 December 1994
Resolved 20 December 1994
Fire Fighting
Issued 10 March 1990 Resolved
PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP
Condition: Unknown
Due 10 March 1990
Resolved 10 March 1990
Navigation
Issued 10 March 1990 Resolved
REMOVE ALL PAINT FROM STEERING GEAR ROOM.
Condition: Unknown
Due 10 March 1990
Resolved 10 March 1990
Deck/Cargo
Issued 10 March 1990 Resolved
REPLACE LEAKING CARGO VALVE IN #2 CARGO TANK.
Condition: Unknown
Due 10 March 1990
Resolved 10 March 1990
Deck/Cargo
Issued 15 January 1989 Resolved
#4 PORT VENT PIPING WASTED INWAY OF EXPANSION TRUNK. MAKE PERMANENT REPAIRIN LIEU OF TEMPORARY REPAIR PRIOR TO 15 JULY 1989
Condition: Unknown
Due 15 January 1989
Resolved 15 January 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.