MAURY USCG vessel records Sign in
← All vessels

MARGAUX

MARGAUX is a 1976 tank ship. The Coast Guard has recorded 24 inspections since 1986, most recently in February 2005, along with 8 deficiencies and 2 operational controls.

Records from 1986 to 2005. Most recent: operational control imposed, 11 February 2005.

Built
1976
Last inspected
11 February 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7403354 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224984
Flag
PANAMA
—
Maury page id
psix-224984

Inspections, by type

…with no type recorded12
Years with a record 13 calendar years (1986–2005)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it104296 - Regulatory (Subpart C or D), Net Ton
131303 - Regulatory (Subpart C or D), Gross Ton
274165 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

11 February 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2290629
10 February 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2290089
1 February 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1998352
29 January 2004 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1997111
25 March 2003 Ballast Water Examination · Certificate of Compliance
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1763208
20 January 2002 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1480197
5 December 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 437122
5 December 1999 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 813311
31 July 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 431022
5 January 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 424336
15 January 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 412016
15 January 1998 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 776708
4 February 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 400105
20 October 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1180037
5 August 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 368793
5 August 1994 Tank Vessel Examination · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380040
9 March 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 356890
9 March 1993 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1150345
25 June 1992 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1263515
28 February 1992 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1270295
28 January 1991 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1240226
14 August 1987 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 318008
14 August 1987 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1033387
22 June 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 309712

Deficiency record · 8

Deck/Cargo
Issued 5 January 1999 Resolved
PROCURE TWO 10 INCH REDUCERS FOR EMERGENCY LIGHTERING PRIOR TO REENTERING U.S. WATERS AS PER 33 CFR 157.410.
Condition: Unknown
Due 1 August 1999
Resolved 1 August 1999
Navigation
Issued 4 February 1997 Resolved
PROVIDE ON BOARD AN AUTOPILOT ALARM THAT SOUNDS AN ALARM ON THE BRIDGE WHENSTEERING CHANGES ARE MADE WHEN THE VESSELS AUTOPILOT IS ENGAGED._x001C_ 33 CFR 157.440
Condition: Unknown
Due 28 February 1997
Resolved 13 February 1997
Accommodation/Occupational Safety
Issued 5 August 1994 Resolved
VSL HAS INSTALLED TOILETS. VSL HAS A TYPE II MSD INSTALLED. THE MSD IS NOT LABELED OR MARKED IN ANY MANNER.
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Accommodation/Occupational Safety
Issued 5 August 1994 Resolved
PROVIDE ONBOARD CERTIFICATION OF THE EXISTING MARINE SANITATION DEVICE IN ACCORDANCE WITH 33CFR159.12c.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Deck/Cargo
Issued 5 August 1994 Resolved
USE OF #3 CARGO PUMP IS PROHIBITED DURING CARGO TRANSFER OPERATIONS. _x001C_ PROVIDE CLASSIFICATION SOCIETY SURVEY REPORT FOR ACCEPTANCE OF TEMPORARY_x001C_ REPAIRS OR COMPLETION OF PERMANENT REPAIRS.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Engineering
Issued 25 June 1992 Resolved
PROVE PROPER OPERATION OF OWS AND 15 PPM ALARM PRIOR TO TRANSFER AT NEXT U.S. PORT.
Condition: Unknown
Due 25 June 1992
Resolved 25 June 1992
Deck/Cargo
Issued 28 February 1992 Resolved
PROVE PROPER OPERATION OF O2 ANILIZER PRIOR TO OIL TRANSFER NEXT U.S. PORT.
Condition: Unknown
Due 28 February 1992
Resolved 28 February 1992
Engineering
Issued 28 February 1992 Resolved
PROVE PROPER OPERATION OF OWS AND 15 PPM ALARM PRIOR TO OIL TRANSFER NEXT U.S. PORT.
Condition: Unknown
Due 28 February 1992
Resolved 28 February 1992

Ownership record