MAURY USCG vessel records Sign in
← All vessels

HELI

HELI is a 1975 offshore supply vessel. The Coast Guard has recorded 72 inspections since 1985, most recently in December 2016, along with 231 deficiencies and 1 operational control.

Records from 1985 to 2016. Most recent: inspection, 29 December 2016.

Built
1975
Last inspected
29 December 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7403469 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224992
Flag
BAHAMAS, THE
—
Maury page id
psix-224992

Inspections, by type

…with no type recorded20
Years with a record 20 calendar years (1985–2016)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it5185 - Convention (Subpart B), Net Ton
23835 - Displacement, Ton
8422 - Dead Weight, Ton
17284 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 72

29 December 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6062815
27 June 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5921179
10 February 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5812647
16 September 2015 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5753517
27 August 2015 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5228097
17 July 2015 COC-MODU Annual
Type not classified · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5187533
16 May 2014 COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4854319
1 May 2014 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4848060
19 May 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1063788
17 April 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1066547
14 April 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061610
2 April 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1366265
8 February 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 121616
19 January 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 768393
16 January 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 208236
11 May 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049889
4 April 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417043
25 March 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1047728
24 September 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1035107
7 September 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 782006
18 June 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1190139
4 June 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803255
5 April 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413506
28 December 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 809195
27 April 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 792242
6 April 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449032
6 February 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 774279
9 December 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 777613
18 November 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1109189
1 September 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785108
11 July 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778438
12 May 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1102913
17 April 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 57755
8 April 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1404339
29 January 1997 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1102835
18 September 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1134328
16 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1095427
9 April 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1441080
2 April 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404126
20 March 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1078698
14 November 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 875201
9 June 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1186095
16 May 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920241
3 April 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462437
10 March 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1173121
9 September 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 34970
24 August 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 50906
24 May 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 131219
14 May 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 67655
4 April 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409107
21 March 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1165592
7 May 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1136245
6 April 1993 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472308
9 March 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1266908
7 February 1992 Certificate of Compliance · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1257716
16 December 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1267382
11 June 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239351
8 February 1991 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1303401
12 April 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 917682
5 February 1990 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1221430
28 September 1989 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1314904
9 August 1989 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1351892
11 May 1989 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1203027
31 January 1989 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1036828
6 April 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302077
8 February 1988 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276228
1 February 1987 Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1014783
17 June 1986 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 999498
15 May 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988135
15 March 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001362
23 December 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987150
18 January 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980817

Deficiency record · 231

Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 23 July 2015 Resolved
Emergency generator did not shut down under low l/o pressure. Ensure low l/o pressure shutdown works as required.
Action required: 705 - Other - as specified
Due 23 September 2015
Resolved 27 August 2015
Resolution: Vessel installed new L/O pressure alarm/shutdown. Witnessed satisfactory test of alarm/shutdown.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 23 July 2015 Resolved
Multiple fire doors for stairtowers and stairways did not close and latch and had mechanical holdbacks. Ensure doors self-close that are required to be selfclosing and remove mechanical holdbacks.
Action required: 705 - Other - as specified
Due 23 August 2015
Resolved 27 August 2015
Resolution: Vessel removed all tie back devices and adjusted all self closing doors. Witnessed satisfactory test of self-closing fire doors.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 23 July 2015 Resolved
Multiple distribution panel were missing front panels exposing personnel to electrical hazards. Survey all panels onboard vessel to ensure panels cover all electrical hazrds inside panels.
Action required: 705 - Other - as specified
Due 23 August 2015
Resolved 27 August 2015
Resolution: Vessel installed plexi-glass in all breaker panels covering the potential electrical hazards.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 23 July 2015 Resolved
Cable penetrations in emergency generator space were found to be filled with an unapproved fire stop system. Replace cable penetrations with approved sealant system.
Action required: 705 - Other - as specified
Due 23 August 2015
Resolved 27 August 2015
Resolution: Vessel removed old cable penetration packing and used STI Marine Fire stop rated for A-60 boundaries. All penetrations sat.
Lifesaving › Launching Appliances › Davit
Issued 16 May 2014 Resolved
Found that #3 lifeboat davit aft slide arm was deformed. Have OEM attest that the slide arm is serviceable and not in need of replacement.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 2 June 2014
Resolution: Received an email from [name withheld] on 2Jun2014 showing OEM stated that the slide arm is serviceable and not in need of replacement.
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 16 May 2014 Resolved
While running the emergency generator a water leak was found on the water jacket at the aft end on the top.
Action required: 705 - Other - as specified
Due 23 May 2014
Resolved 2 June 2014
Resolution: Received an email from [name withheld] on 2Jun2014 stating that the jacket water cooling flange o-ring had been changed and the leak repaired.
Stability › Watertight Integrity › General
Issued 16 May 2014 Resolved
Found the aft sliding watertight door was inoperative. Repair and prove proper operation of the sliding watertight door.
Action required: 705 - Other - as specified
Due 23 May 2014
Resolved 22 May 2014
Resolution: Received email from [name withheld] on 22May2014 stating the solenoid block valve had been replaced and the door was operating properly.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 16 May 2014 Resolved
New CO2 sirens have been installed and not labeled. Properly label the newly installed CO2 sirens.
Action required: 705 - Other - as specified
Due 23 May 2014
Resolved 22 May 2014
Resolution: Received an email from [name withheld] on 22May2014 showing that the signs had been installed.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 16 May 2014 Resolved
Blanks missing in panel boxes L-23 & L-24 located in SCR room.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 22 May 2014
Resolution: Received an email from [name withheld] on 22May2014 showing that blanks had been installed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 May 2014 Resolved
Generator room open junction box below hatch with dead-end wires hanging out of the box.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 22 May 2014
Resolution: Received email from [name withheld] on 22May2014 showing the old junction box had been removed and replaced.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 May 2014 Resolved
Broken electrical plug assembly on the stern starboard old helo deck area. (Hanging by wires).
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 22 May 2014
Resolution: Received an email from [name withheld] on 22May2014 showing that the junction box had been removed and replaced with a new one.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 May 2014 Resolved
H2S Sensor located starboard side stern had wires hanging out of the junction box.
Action required: 705 - Other - as specified
Resolved 16 May 2014
Resolution: Repaired while the inspection team was onboard.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 May 2014 Resolved
Junction box on port side by old shale shaker area had a hanging junction box with a disconnected bonding wire.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 2 June 2014
Resolution: Received an email from [name withheld] on 2Jun2014 showing the junction box mounted and properly grounded.
Fire Fighting › Nozzles › Condition
Issued 16 May 2014 Resolved
PMS fire station 11 on the rig floor to ensure the nozzle is in working condition and a spanner wrench is present.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 2 June 2014
Resolution: Received an email from [name withheld] on 2Jun2014 showing that the nozzle had been replaced and a spanner wrench was present.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 May 2014 Resolved
Ensure hazardous class 1 division 1 panel on the drill floor is installed per manufacturer manual. Sealing surface was stuffed with grease wrap.
Action required: 705 - Other - as specified
Due 23 May 2014
Resolved 22 May 2014
Resolution: Received an email from [name withheld] on 22May2014 showing that the grease wrap was removed and panel is installed correctly.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 16 May 2014 Resolved
Provide proof that the CO2 systems were modified prior to July 19, 2013 or meet the requirements of 46 CFR 108.431 for fixed gas extinguishing systems.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 2 June 2014
Resolution: Received an email from [name withheld] on 2Jun2014 stating that the changes were made prior to 2013.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 16 May 2014 Resolved
Conduct 5 year crane overload test on the stbd crane
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 18 June 2014
Resolution: Received an email from [name withheld] on 18Jun2014 with an attached ABS Statement of Fact showing the crane tests.
Lifesaving › Launching Appliances › Winch
Issued 9 May 2014 Resolved
Unsuccessfully attempted to launch #3 lifeboat from the self-launching system. After finding the system inoperative the crew attempted to launch the #4 lifeboat and found that it too would not launch. Repair and prove proper operation of self-launching systems on all four installed lifeboats.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2014
Resolution: Received an email from [name withheld] on 22May2014 attesting to the repairs and proper operation of self-launching systems on all four installed lifeboats.
Documentation › Certificates/Documents › MODU Safety Certificate
Issued 9 May 2014 Resolved
MODU Code Safety Certificate lists the aggregate vessel capacity as 285 persons when it should read 300. Have Classification Society correct the certificate and reissue.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 2 June 2014
Resolution: Received an email from [name withheld] on 2Jun2014 showing ABS surveyor [name withheld] had corrected and reissued the certificate.
Documentation › Certificates/Documents › Annex VI Statement of Voluntary Compliance Supplement
Issued 9 May 2014 Resolved
International Sewage Pollution Prevention certificate shows the system is built to accommodate 140 persons. If the certificate is correct the POB needs to be reduced to 140 persons. If the certificate has the incorrect capacity have the Classification Society correct and reissue the certificate.
Action required: 705 - Other - as specified
Due 16 June 2014
Resolved 30 March 2016
Resolution: Received an email from [name withheld] on 02Jun2014 stating the capacity had been corrected and ABS Surveyor [name withheld] had corrected and reissued the certificate.
Construction/Loadline
Issued 2 April 2001 Resolved
Ensure stairway doors are self closing and in compliance with CH 9 of Code (to be addressed by Class Society).
Condition: Unknown
Due 4 May 2001
Resolved 27 April 2001
Construction/Loadline
Issued 2 April 2001 Resolved
Class Society (ABS) to survey, identify and rectify discrepancies with regard to fire integrity of bulkheads separating adjacent spaces per CH. 9 of Code. Any changes to be further addressed on Fire Safety Plan.
Condition: Unknown
Due 4 May 2001
Resolved 27 April 2001
Lifesaving
Issued 4 April 2000 Resolved
OPERATE ALL FOUR LIFEBOATS IN WATER. EACH BOAT MUST BE OPERATED IN WATER EVERY 3 MONTHS. PROVIDE RETRO TAPE ON RESCUE BOAT.
Condition: Unknown
Due 4 May 2000
Resolved 3 May 2000
Engineering
Issued 4 April 2000 Resolved
RELOCATE OR HARDPIPE LUBE OIL SUPPLY TO AFT THRUSTERS ON STARBOARD AFT THRUSTER WALKWAY.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Lifesaving
Issued 4 April 2000 Resolved
CONDUCT SATISFACTORY TEST OF TOTAL RIG SHUTDOWN, AUXILIARY GEN. ABT AND EMERGENCY GEN. ABT.
Condition: Unknown
Due 4 May 2000
Resolved 3 May 2000
Deck/Cargo
Issued 4 April 2000 Resolved
GAUGE ALL SEACHESTS TO SATISFACTION OF ATTENDING CLASS SURVEYOR.
Condition: Unknown
Due 4 May 2000
Resolved 11 May 2000
Deck/Cargo
Issued 4 April 2000 Resolved
RENEW TOP CAB WINDOW TO FWD 60 CRANE.
Condition: Unknown
Due 4 May 2000
Resolved 3 May 2000
Lifesaving
Issued 4 April 2000 Resolved
RENEW DETERIORATED HATCH SEALS ON LIFEBOATS 3 & 4.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Deck/Cargo
Issued 4 April 2000 Resolved
CROP AND RENEW WASTED VENT TRUNK AT #136 BULK MUD TANK SPACE.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Deck/Cargo
Issued 4 April 2000 Resolved
GAUGE APV'S THAT ARE EXPOSED TO WEATHER TO SATISFACTION OF ATTENDING CLASS SURVEYOR.
Condition: Unknown
Due 4 May 2000
Resolved 11 May 2000
Deck/Cargo
Issued 4 April 2000 Resolved
PROVIDE PROOF OF ANNUAL INSPECTION OF ELEVATOR AND 5 YEAR LOAD TEST. SUBMITPLANS FOR REPLACING ELEVATOR EQUIPMENT TO CLASS FOR APPROVAL. PROVIDE "E" LIGHTS FOR ELEVATOR ESCAPE LADDER.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Unknown
Issued 4 April 2000 Resolved
PROVIDE 100 PSI OR LESS SAFETY RELIEF VALVES FOR HOT WATER HEATERS.
Condition: Unknown
Due 4 May 2000
Resolved 3 May 2000
Electrical
Issued 4 April 2000 Resolved
RENEW CHAFFED WIRING ON SHAKERS, PROPERLY MOUNT J-BOXES ON DRILL FLOOR.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Electrical
Issued 4 April 2000 Resolved
PROVIDE DOCUMENTATION OF TESTING EMERGENCY BATTERIES FOR TWO HOUR LOAD TESTEVERY SIX MONTHS.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Unknown
Issued 5 April 1999 Resolved
SUBMIT AN UPDATED AND REVISED SAFETY PLAN THAT MEETS IMO RESOLUTION A.414 AND IDENTIFIES CLASS A BOUNDRIES FOR APPROVAL BY CLASS SOCIETY.
Condition: Unknown
Due 5 April 1999
Resolved 5 April 1999
Fire Fighting
Issued 6 April 1998 Resolved
Complete deficiency list in accordance with Gulf Wide Safety Systems Fire Fighting Servicing Report, dated 12MAR98.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Fire Fighting
Issued 8 April 1997 Resolved
POST CO2 ACTIVATION INSTRUCTIONS AND WARNING PLACARD FOR AUXILLIARY GENERATOR SPACE.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Engineering
Issued 8 April 1997 Resolved
PROVIDE FLAME SCREENS ON VENTS FOR LUBE OIL AND FUEL OIL TANKS LOCATED IN AUXILLIARY GENERATOR SPACE.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Lifesaving
Issued 8 April 1997 Resolved
CONDUCT COMPLETE OPERATIONAL TESTS OF ALL LIFEBOATS AND THE RESCUE BOAT PER33 CFR 146.205(b).
Condition: Unknown
Due 8 April 1997
Resolved 8 April 1997
Accommodation/Occupational Safety
Issued 8 April 1997 Resolved
INTERNALLY EXAMINE ALL PRESSURE VESSELS AND TEST ALL RELIEF DEVICES PER NVIC 3-88, 7.D.2.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Documentation
Issued 8 April 1997 Resolved
SUBMIT OPERATIONS MANUAL, FOLLOWING FLAG ADMINISTRATION APPROVAL, TO COGNIZANT OCMI FOR REVIEW PER NVIC 3-88 PART 9.
Condition: Unknown
Due 8 April 1997
Resolved 8 April 1997
Lifesaving
Issued 8 April 1997 Resolved
RELOCATE RING LIFE BUOY FROM AFT OF NO. 1 LIFEBOAT TO MORE ACCESSABLE LOCATION.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Lifesaving
Issued 8 April 1997 Resolved
COMPLETE LIFEBOAT MAINTENANCE AND REPAIRS PER WORKLIST DATED 08 APRIL, 1997, ISSUED THIS CASE.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Lifesaving
Issued 9 April 1996 Resolved
ADJUST LIMITING SWITCH ON #4 LIFEBOAT._x001C_ _x001C_
Condition: Unknown
Due 25 April 1996
Resolved 19 June 1996
Lifesaving
Issued 9 April 1996 Resolved
REPAIR GUAGE AND BREATHING AIR SYSTEM ON #4 LIFEBOAT.
Condition: Unknown
Due 25 April 1996
Resolved 19 June 1996
Lifesaving
Issued 9 April 1996 Resolved
REPAIR COMPASS IN #2 LIFEBOAT.
Condition: Unknown
Due 25 April 1996
Resolved 19 June 1996
Documentation
Issued 9 April 1996 Resolved
PROVIDE FULL TERM SAFETY CONSTRUCTION, EQUIPMENT, AND IMO CODE CERTIFICATESFROM CLASS SOCIETY.
Condition: Unknown
Due 9 April 1996
Resolved 9 April 1996
Lifesaving
Issued 9 April 1996 Resolved
service liferafts #4 and #5.
Condition: Unknown
Due 25 April 1996
Resolved 19 June 1996
Electrical
Issued 9 April 1996 Resolved
secure loose wiring on upper moonpool deck.
Condition: Unknown
Due 25 April 1996
Resolved 19 June 1996
Lifesaving
Issued 9 April 1996 Resolved
install track guards on all lifeboat davits.
Condition: Unknown
Due 25 April 1996
Resolved 19 June 1996
Lifesaving
Issued 9 April 1996 Resolved
RECHARGE AIR BOTTLE ON #2 LIFEBOAT.
Condition: Unknown
Due 25 April 1996
Resolved 19 June 1996
Construction/Loadline
Issued 3 April 1995 Resolved
PROVIDE COUNTERWEIGHTS FOR EMERGENCY ESCAPE SCUTTLES AS NEEDED.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 3 April 1995 Resolved
HAVE BREATHING AIR BOTTLES IN LIFEBOATS HYDROSTATICALLY TESTED AS NEEDED.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Electrical
Issued 3 April 1995 Resolved
REPLACE GENERAL ALARM BELL ON DRILL FLOOR, GENERAL ALARM CONTACT MAKER AND VENTILATION SHUTDOWN SWITCH IN SHAKER AREA WITH APPROVED EXPLOSION PROOF TYPE FITTINGS.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Electrical
Issued 6 April 1993 Resolved
CONDUCT TOTAL RIG SHUTDOWN.
Condition: Unknown
Due 6 April 1993
Resolved 6 April 1993
Electrical
Issued 6 April 1993 Resolved
REPAIR PURGE ALARM ON TOP DRIVE TELEVISION MONITOR ENCLOSURE AT DRILLERS CONSOLE.
Condition: Unknown
Due 6 April 1993
Resolved 6 April 1993
Electrical
Issued 6 April 1993 Resolved
REPLACE (OR MOVE TO SUITABLE LOCATION) SWITCH BOXES FOR SWACO MUD CLEANERS IN ACTIVE MUD PIT ROOM.
Condition: Unknown
Due 6 April 1993
Resolved 6 April 1993
Electrical
Issued 6 April 1993 Resolved
REPLACE NON-EXPLOSION PROOF J-BOX IN ACTIVE MUD PIT ROOM AT PORT FWD EXIT.
Condition: Unknown
Due 6 April 1993
Resolved 6 April 1993
Accommodation/Occupational Safety
Issued 7 February 1992 Resolved
RENEW CORRODED PIPING RUNNING BEHIND PANELS IN MAIN DECK PASSAGEWAY BY #20 FIRE STATION.
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Electrical
Issued 7 February 1992 Resolved
REPAIR DOOR ON ELECTRIC PANEL "EL 28" IN PROPULSION ROOM BY #15 FIRE STATION.
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Fire Fighting
Issued 7 February 1992 Resolved
LOOSEN SEMI-FROZEN VALVE FOR HAND OPERATION ON #56 FIRE STATION.
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Lifesaving
Issued 7 February 1992 Resolved
RECHARGE EMERGENCY AIR BOTTLES IN #2 LIFEBOAT.
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Lifesaving
Issued 7 February 1992 Resolved
CHANGE FUEL IN #1, #3, AND #4 LIFEBOATS.
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Lifesaving
Issued 7 February 1992 Resolved
HAVE #3 AND #4 LIFERAFTS SERVICED AT AN APPROVED FACULTY.
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Electrical
Issued 7 February 1992 Resolved
ATTACH SAFETY LEASES TO ALL FIXTURES LOCATED IN THE HAZARDOUS LOCATIONS (PAINT LOCKER INCLUDED) THAT ARE NOT PERMENTANTLY ATTACHED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 March 1992
Resolved 28 February 1992
Lifesaving
Issued 7 February 1992 Resolved
CONDUCT TEST OF GENERAL ALARM SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Engineering
Issued 7 February 1992 Resolved
REPAIR ALL FUEL VENTS FOR PROPER SEAL AROUND FLAME SCREENS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Electrical
Issued 7 February 1992 Resolved
CONDUCT TEST OF ALL EMERGENCY REMOTE SHUT-DOWNS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Engineering
Issued 7 February 1992 Resolved
CONDUCT INTERNAL INSPECTION OF ALL PRESSURE VESSELS AND TEST RELIEF VALVES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 March 1992
Resolved 28 February 1992
Engineering
Issued 7 February 1992 Resolved
PROVIDE OIL TRANSFER PROCEDURES AS PER 33 CFR 150.143._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Lifesaving
Issued 7 February 1992 Resolved
RENEW LIFELINES ON #1 AND #2 LIFEBOATS.
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Construction/Loadline
Issued 7 February 1992 Resolved
REPAIR THE PORT BILGE PUMP IN THE MUD PUMP ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Construction/Loadline
Issued 7 February 1992 Resolved
REPAIR THE PROPULSION ROOM PORT BILGE ALARM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Lifesaving
Issued 7 February 1992 Resolved
OPERATE ALL LIFEBOATS IN THE WATER AND TEST SPRINKLER SYSTEM AND WATERTIGHTNESS OF WINDOWS AND HATCHES WHEN WEATHER PERMITS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Lifesaving
Issued 7 February 1992 Resolved
PROVIDE A JACKNIFE WITH OPENER, COMPASS LIGHT, EXTRA FLASHLIGHT BULB, SMOKESIGNAL, RECHARGE FWD EMERGENCY AIR BOTTLE, AND REMOUNT AIR RELEASE VALVE IN#4 LIFEBOAT.
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Lifesaving
Issued 7 February 1992 Resolved
RENEW EXPIRED SMOKE SIGNAL ON PORT BRIDGE WING RING BUOY.
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Electrical
Issued 16 December 1991 Resolved
TIGHTEN EYS FITTING ON JUNCTION BOX BEHIND DRILLER'S CONSOLE ON DRILL FLOOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Lifesaving
Issued 16 December 1991 Resolved
PROVIDE COMPLETE ENCLOSURE OF MUD AGITATOR PUMP ROTATING SHAFT IN RESERVE MUD PITS ON PORT AFT PUMP AND UPPER MUD PITS ON PORT AFT PUMP._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Lifesaving
Issued 16 December 1991 Resolved
REPLACE MISSING BOLTS FOR GUARD ON PHONE LIGHT IN MUD PUMP ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Lifesaving
Issued 16 December 1991 Resolved
REPLACE BROKEN GUARD TO GAS WARNING LIGHT IN MUD PIT AREA._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Electrical
Issued 16 December 1991 Resolved
REPLACE MISSING BOLTS ON EXPLOSION PROOF SWITCH BOXES FOR SHAKERS ALONG PORT BULKHEAD IN MUD PITS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Electrical
Issued 16 December 1991 Resolved
REPLACE MISSING BOLTS ON SWACO MUD PUMP EXPLOSION PROOF BOX IN MUD PITS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Electrical
Issued 16 December 1991 Resolved
PROVIDE JUNCTION BOX TO REPLACE SPICE OVER #3 SHAKER FROM AFT IN MUD PITS._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Electrical
Issued 16 December 1991 Resolved
LABEL EXPLOSION PROOF SWITCH BOX PORT FWD DRILL FLOOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE SEALING RING TO STBD AFT SIDESHELL TO EMD EXHAUST PENETRATION (NOTE: APPROX 2" OPENING CONTINUOUS APPROVED EXHAUST.)
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR ANNUNCIATOR LIGHTS #2 EMD.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR LIGHT FOR STARBOARD RUDDER ANGLE INDICATOR ON BRIDGE.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR OR REPLACE 2 EA BATTERY POWERED EMERG. LIGHTING IN SCR ROOM AND MAINGENERATOR ROOM.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE EXTINGUISHED EMERGENCY LIGHT IN SECONDARY EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR LOSS OF STEERING AUDIBLE ALARM ON BRIDGE MASTER PANEL.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE GENERATOR ALARM BATTERIES AND TEST GENERAL ALARM SYSTEM IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR SOUND POWERED PHONE NOTIFICATION HORN AND LIGHT IN SECONDARY EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROVIDE PROPER LOSS OF PURGE ALARM FOR T.V. MONITORS ABOVE DRILLER'S CONSOLE RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR ROTATING WIND WAVE ANEMDMETER UNIT ON BRIDGE.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE FITTINGS (WASTED) TO EXPLOSION PROOF JUNCTION BOXES FOR VENTILATORSSTBD SHAKER AREA.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROPERLY MARK ALL LIGHTS, WHISTLES, ALARMS AND WARNING DEVICES IN SHAKER AREA.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE MISSING BOLTS TO EXPLOSION PROOF JUNCTION BOX TO SWACO "VIBRO MUD CLEANER" LOCATED IN SHAKER AREA.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROVIDE PROPER SEALED FITTINGS FOR ZONE 1 INSTALLATION ON ALL ELECTRICAL PENETRATIONS TO SWACO MUD PUMPS LOCATED IN SHAKER AREA.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROVIDE PROPER SEALED FITTINGS TO ALL ELECTRICAL PENETRATIONS TO SWACO MUD CLEANING UNITS LOCATED IN SHAKER AREA.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR TACHOMETER ON #1 EMD.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
ADJUST BRAKE ON #3 L/B WINCH TO PREVENT SLIPPAGE.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE OR PROVIDE PROPER DOCUMENTATION OF MANUFACTURING DATE OF DISPOSABLEHAMMER HRV'S ON #7 AND 8 L/R'S.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROVIDE BATTERY POWERED EMERGENCY LIGHTING FOR PRIMARY EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR INDICATOR LAMPS ON NAV LIGHT PANEL.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
MOUNT PROPERLY EXPLOSION PROOF JUNCTION BOX PORT AFT SHAKER AREA ON AFT BULKHEAD.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROVIDE EXPLOSION PROOF ITERCOM BOX FOR DERRICK CONTROL CAB (CRANE) RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE ZEA WASTED EXPLOSION PROOF PULL BOXES ON EXPLOSION PROOF SWITCH BOXCONDUIT TO AFT AND THIRD FROM AFT SHALE SHAKER UNITS, IN SHAKER AREA.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE SEA WASTED EXPLOSION PROOF JUNCTION BOXES; PROPERLY MOUNT; LOCATED IN CABLE TRAY ABOVE SHALE SHAKERS.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROVIDE EXPLOSION PROOF INTERCOM FOR NON-EXPLOSION PROOF TYPE IN SHALE SHAKER.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR VENTILATION FANS AND VENT PLENUM SHUT OFFS FOR ACTUAL AND RESERVE MUD PITS. (NOTE: REPEAT DISCREPANCY FROM 28 FEB 89 INSPECTION.)
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE BROKEN COVER AND FASTENERS TO EXPLOSION PROOF GENERAL ALARM CONTACTMAKER PORT FORWARD SHALE SHAKER AREA.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
MOUNT PROPERLY EXPLOSION PROOF JUNCTION BOX LOCATED PORT FORWARD BULKHEAD OF SHALE SHAKER.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR AND PROVE OPERATION OF LOSS OF PURGE ALARMS AND POWER SHUT OFFS TO MUD LAB LOCATED IN SHAKER AREA.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE MISSING GUARD TO EXPLOSION PROOF LIGHT LOCATED ABOVE DE-SANDER AND DE-SILTER PUMPS BELOW SHAKER AREA.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROPERLY MARK GENERAL ALARM BELL/PROVIDE MISSING RED LENS FOR GENERAL ALARMLIGHT; FORWARD BULKHEAD OF MECHANICAL CASING STORE ROOM.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROVIDE POSITIVE PRESSURE TO MUD PUMP ROOM WITH RESPECT TO SHAKER AREA AND RESERVE MUD PITS, AND REPAIR VENTILATION AND LOSS OF VENTILATION ALARMS.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REMOVE DEAD ENDED WIRING, PROPERLY MOUNT EXPLOSION PROOF JUNCTION BOX IN CABLE TRAY PORT FORWARD RESERVE MUD PITS.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR ALL INOPERATIVE WARNING BELLS FOR POWER OPERATED WATER TIGHT DOORS.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE MISSING BOLTS TO EXPLOSION PROOF SWITCH BOX ON AFT BULKHEAD BY WATER TIGHT DOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
FASTEN ALL GUARDS ON ROTATING MACHINERY IN RESERVE MUD PITS.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
MARK PROPERLY GENERAL ALARM BELL AFT BULKHEAD IN RESERVE MUD PITS BY WATER TIGHT DOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE MISSING GUARD ON LIGHT IN PAINT LOCKER.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR RESET BUTTON TO MOTOR CONTROLLER FOR EMERGENCY COOLING PUMP; LOCATEDIN EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR SOUND POWERED PHONE NOTIFICATION LIGHT AND ALARM IN THE PRIMARY AND SECONDARY EMERGENCY GENERATOR SPACES.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROVIDE COVER FOR EMERGENCY BUS SWITCHBOARD (AFT ENCLOSURE) LOCATED IN EMERG. GEN. SPACE.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE MISSING BOLT EXPLOSION PROOF GENERAL ALARM DRIVER PORT FORWARD RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE MISSING GUARDS TO EXPLOSION PROOF LIGHTS IN UPPER MOON POOL.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROPERLY HANG ALL VERTICAL RUNS OF WIRING PORT FORWARD DERRICK LEG - RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR LOW LUBE OIL LEVEL ALARM AND LOW OIL TEMP ALARM #2 EMD.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROVIDE DOCUMENTARY EVIDENCE OF COMPLETION OF MOST RECENT DRYDOCKING (SEP 1990).
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
HAVE ANNUAL SERVICING/TESTING PERFORMED ON CRANES BY AUTHORIZED AGENCIES.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE EXTINGUISHED HELO DECK PERIMETER LIGHTS (5 TOTAL).
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REVISE THE OPERATIONS MANUAL TO INCLUDE THE FOLLOWING INFORMATION AS PER 46CFR 109.121(C): COMPREHENSIVE LISTING OF THE INCLUSIONS AND EXCLUSIONS OF SEMI-PERMANENT EQUIP FOR DETERMINING LIGHT WEIGHT ALTERATIONS (5).
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REVISE THE OPERATIONS MANUAL TO INCLUDE THE FOLLOWING INFORMATION AS PER 46CFR 109.121(C): LIST OF EMERG. SHUT-DOWNS AND GUIDANCE ON RESTARTING ALL MECH., VENT, AND ELEC. EQUIP AFTER ACTIVATION OF THE SHUT-DOWN (2).
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REVISE THE OPERATIONS MANUAL TO INCLUDE THE FOLLOWING INFORMATION AS PER 46CFR 109.121(C): PERSONNEL EVACUATION PROCEDURES (22).
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REVISE THE OPERATIONS MANUAL TO INCLUDE THE FOLLOWING INFORMATION AS PER 46CFR 109.121(C): SCHEMATIC DIAGRAM OF EMERG. POWER SYSTEM (24).
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REVISE THE OPERATIONS MANUAL TO INCLUDE THE FOLLOWING INFORMATION AS PER 46CFR 109.121(C): GUIDANCE FOR PIC TO DETERMINE THE CAUSE OF UNEXPECTED LISTOR TRIM BEFORE TAKING CORRECTIVE ACTION (17).
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR HIGH TEMPERATURE ALARM #2 EMD.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR LOW TURBO CHARGER OIL PRESSURE ALARM ON #5 EMD.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROVIDE MISSING COVERS FOR ANNUNCIATOR LIGHTS #3 EMD.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR BELLS TO ENGINE ORDER TELEGRAPH UNIT AT ENGINEROOM MAIN PROPULSION CONTROL STATION IN LOWER SCR ROOM.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR SOUND POWERED PHONE VISUAL AND AUDIBLE NOTIFICATION ALARMS AT ENGINEROOM MAIN PROPULSION CONTROL STATION IN LOWER SCR ROOM.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR OR REPLACE ALL BILGE ALARMS IN FWD/AFT PUMPROOMS MUD PUMP ROOM, LOWER SCR ROOM, ETC AND PROVE OPERATION SATISFACTORY TO THE ATTENDING COASTGUARD INSPECTOR. (NOTE: REPEAT DISCREPANCY FROM 31 JAN 89 INSPECTION.)
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
CROP/RENEW TO GOOD METAL WASTED SALT WATER MAIN IN VICINITY OF 3'X3'X3' CEMENT PITCH LOCATED IN AFT PUMPROOM.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR OR REPLACE BATTERY POWERED "E" [name withheld] FIRE PUMPS.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPAIR OR REPLACE FWD MASTHEAD LOWER LIGHT.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
OBTAIN VALID LOAD LINE CERTIFICATE.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
OBTAIN APPROVAL/EXEMPTION FOR RELOCATION OF MASTHEAD TO DERRICK.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
POUR EYS FITTING TIGHTEN EXPLOSION PROOF UNION ON EXPLOSION PROOF BREAKER BOX "L30" RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROVIDE SEALED FITTING FOR "LOCK OUT" EXPLOSION PROOF SWITCH BOX TO FORWARDPROW WORKS MOTOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
POUR EYS FITTING TO EXPLOSION PROOF SWITCH BOX FOR AIR DRYER PORT SIDE RIG FLOOR (ENSURE OUTER CONDUCTORS ARE STRIPPED BACK TO ENSURE SEALING AROUND INNER CONDUCTORS.)
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
POUR 6 EA EYS FITTINGS ON 3 EXPLOSION PROOF SWITCH BOXES AFT OF DRILLER'S HOUSE RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROPERLY INSTALL ALL VERTICAL RUNS OF WIRING AFT OF DRILLER'S HOUSE RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REMOVE EYS FITTING WITH DEAD ENDED WIRING/PLUG OPENING TO EXPLOSION PROOF JUNCTION BOX AFT OF DRILLER'S HOUSE RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
POUR EYS FOR 2 EA EXPLOSION PROOF THERMOSTAT SWITCH BOXES AFT OF DRILLER'S HOUSE RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROVIDE SEALED FITTING FOR EXPLOSION PROOF SWITCH BOXES FOR GAS WARNING LIGHT AND BAYLOR BRAKE RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROVIDE PROPER LOSS OF PURGE ALARM FOR DRILLER'S CONSOLE RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROVIDE EXPLOSION PROOF INTERCOM UNIT (TO REPLACE NON-EXPLOSION PROOF TYPE)IN DRILLER'S HOUSE RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROVIDE PROPER LOSS OF PURGE ALARM FOR T.V. MONITORS ABOVE VARCO TOP DRIVE CONTROL PANEL IN DRILLER'S HOUSE RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROPERLY INSTALL HORIZONTAL RUN OF WIRING TO EXPLOSION PROOF LIGHT AFT OF RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROPERLY INSTALL ALL HORIZONTAL AND VERTICAL RUNS OF WIRING PORT FORWARD MEZZANINE DECK ABOVE RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE WIRE WITH BROKEN OUTER CONDUCTOR, TO EXPLOSION PROOF PLUG BOX LOCATED PORT SIDE UPPER MOON POOL AREA IN OVERHEAD.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REMOVE ALL DEAD ENDED WIRING PORT SIDE MEZZANINE DECK FWD OF TOP DRIVE HYDRAULIC UNIT, ABOVE RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REMOVE ALL DEAD ENDED WIRING STBD AFT DERRICK LEG MEZZANINE DECK, ABOVE RIGFLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REMOVE DEAD ENDED WIRING PORT FWD CATWALK BY CABLE REEL BENEATH RIG FLOOR.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROPERLY INSTALL WIRING/REPAIR INTERIOR LIGHT TO PORT FORWARD CRANE.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PLUG OPENING TO EXPLOSION PROOF PLUG BOX STBD FWD LEG UPPER MOON POOL AREA.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROVIDE SEALED FITTING TO EXPLOSION PROOF DRIVER FOR SPEAKER UNIT PORT FWD LEG UPPER MOON POOL.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REMOVE DEAD ENDED WIRING TO UPPER MOON POOL PORT FWD DERRICK LEG.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REMOVE DEAD ENDED WIRING IN OVERHEAD UPPER MOON POOL BY PORT AFT DERRICK LEG.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE BROKEN BULB COVER TO INDICATOR LIGHT ON EXPLOSION PROOF SWITCH BOX STBD SIDE SHAKER AREA.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE WASTED EXPLOSION PROOF PLUG BOX PORT AFT DERRICK LEG UPPER MOON POOL.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE MISSING COVER TO EXPLOSION PROOF PLUG BOX PORT AFT DERRICK LEG UPPER MOON POOL. REMOVE DEAD END WIRING FROM SAME LOCATION.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROPERLY INSTALL JUNCTION BOX & WIRING/REPLACE WIRE WITH BROKEN OUTER CONDUCTOR ON BULKHEAD STBD FWD "ROV" DECK.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE BROKEN EYS FITTING ON EXPLOSION PROOF JUNCTION BOX STBD AFT DERRICKLEG, MOON POOL.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
REPLACE WASTED COVER TO CO2 WARNING HORN STBD SIDE SHAKER AREA.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Unknown
Issued 8 February 1991 Resolved
PROPERLY FASTEN ALL GUARDS ON ROTATING MACHINERY IN SHAKER AREA.
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Documentation
Issued 31 January 1989 Resolved
PROVIDE ONBOARD A VALID CARGO SHIP RADIOTELEPHONY CERTIFICATE, (SOLAS RADIO) EXEMPTION CERTIFICATE, N.P.D.E.S. CERTIFICATE (OR COPY), AND A 'SAFE MANNING CERTIFICATE' OR DOCUMENTS DETAILING REQUIRED SAFE MANNING LEVELS.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Engineering
Issued 31 January 1989 Resolved
MAKE AVAILABLE FOR USCG INSPECTION ALL AIR TENSIONER PRESSURE VESSELS AND FORWARD DRILLFLOOR (DRAW WORKS) AIR RECEIVER. DEMONSTRATE PROPER OPERATION OF ASSOCIATED RELIEF VALVES. THIS MAY OCCUR AT NEXT DRYDOCK OR RIG MOVE; HOWEVER, THE NEXT 2-YR INSPECTION INTERVAL WILL BEGIN 31JAN89.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Lifesaving
Issued 31 January 1989 Resolved
REPLACE BOW DRIVER'S WINDOW ON ALL LIFEBOATS.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Deck/Cargo
Issued 31 January 1989 Resolved
DEMONSTRATE PROPER OPERATION OF BOTH MUD PIT ROOMS VENTILATION DAMPERS AND DOOR SELF-CLOSURE DEVICES.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Deck/Cargo
Issued 31 January 1989 Resolved
DEMONSTRATE 'LOSS OF VENTILATION' ALARMS IN BOTH ACTIVE AND RESERVE MUD PIT ROOMS (ALARM ON INDEPENDENT CIRCUIT).
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Engineering
Issued 31 January 1989 Resolved
DEMONSTRATE PROPER OPERATION OF BILGE ALARMS IN FORWARD PUMPROOM, SEWAGE TREATMENT ROOM, AND PORT AND STBD CEMENT PUMPROOMS.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Unknown
Issued 8 February 1988 Resolved
PROVIDE COMPLETE FIRST AID KITS FOR LIFEBOATS; THREE OF THE FOUR LIFEBOATS HAVE INCOMPLETE UNITS.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Unknown
Issued 8 February 1988 Resolved
PROVIDE EVIDENCE THAT FIXTURES LOCATED IN MUD PITS LABELLED FLAMEPROOF ARE SATISFACTORY FOR CLASSIFIED LOCATIONS AS EXPLOSION PROOF. SHOW FLUORESCENTLIGHTING JUNCTIONS ON DRILL FLOOR SATISFACTORY FOR CLASSIFIED LOCATION. IMO MODU CODE CHAPTER 6; 46 CFR 111.105/46 CFR 108.170
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Unknown
Issued 8 February 1988 Resolved
REPLACE THE TWO EYS FITTINGS ON STARBOARD SIDE FORWARD JUNCTION BOX UNDER DRILL FLOOR IN MOON POOL AREA. REPLACE OTHERS AS NEEDED.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Unknown
Issued 8 February 1988 Resolved
CORRECT HELIDECK LIGHTING ARRANGEMENT TO COMPLY WITH IMO MODU CODE 13.4.3 AND 46 U. S. COASE OF FEDERAL REGULATIONS 108.241.
Condition: Unknown
Due 8 February 1988
Resolved 8 February 1988
Fire Fighting
Issued 1 February 1987 Resolved
PROVIDE A BREATHING APPARATUS OUTSIDE THE REFRIGERATION SPACES ON THE MAIN DECK AND 01 DECK.
Condition: Unknown
Due 1 February 1987
Resolved 1 February 1987
Accommodation/Occupational Safety
Issued 1 February 1987 Resolved
CERTIFY THE MSD IN ACCORDANCE WITH 33 CFR 159.12.
Condition: Unknown
Due 1 February 1987
Resolved 1 February 1987
Accommodation/Occupational Safety
Issued 23 December 1985 Resolved
TEST EMERGENY SHUTDOWNS FOR VENTILATION SYSTEMS IN ACCOMODATION SPACES AND MACHINERY.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Electrical
Issued 23 December 1985 Resolved
MAKE OPERABLE THE LOST AIR PURGE ALARM ON THE DRILLER'S REAR CONSOLE. 46 CFR 108.170.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Electrical
Issued 23 December 1985 Resolved
SEAL OPENING IN THE TOP OF SWITCH BOX L-30 ON DRILL FLOOR, PORT SIDE.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Unknown
Issued 23 December 1985 Resolved
MAKE BOTH CLAYTON STEAM GENERATORS AVAILABLE FOR INSPECTION AND TESTING.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Electrical
Issued 23 December 1985 Resolved
TEST OVERSPEED, LUBE OIL LOW PRESSURE ALARM AND HIGH WATER TEMPERATURE ALARM ON AUXILIARY GENERATOR.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Electrical
Issued 23 December 1985 Resolved
MAKE OPERABLE THE LUBE OIL PRESSURE ALARM ON GENERATORS NO 1, 4, AND 7.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Electrical
Issued 23 December 1985 Resolved
MAKE OPERABLE THE LUBE OIL LOW PRESSURE ALARM, AND HIGH WATER TEMPERATURE ALARM EMERGENCY GENERATOR.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Electrical
Issued 23 December 1985 Resolved
MAKE OPERABLE THE LOSS OF VENTILATION ALARM TO THE MUD PIT ROOMS.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Fire Fighting
Issued 23 December 1985 Resolved
REDUCE FIRE PUMP DISCHARGE PRESSURE TO NOT EXCEED 125 PSIG, OR PROVIDE 25 PSI PRESSURE OVER THE MINIMUM REQUIRED PRESSURE NECESSARY TO OBTAIN 50 PSIG (PITOT GAGE) AT TWO HIGHEST OR FURTHEST FIRE STATIONS.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Fire Fighting
Issued 23 December 1985 Resolved
REPLACE ALL FIRE STATION APPLICATOR TIPS WITH COAST GUARD APPROVED ( NON CLOGGING TYPE) APPLICATOR TIPS.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Electrical
Issued 23 December 1985 Resolved
REMOVE DEAD ENDED CABLES IN BATTERY CHARGER ROOM.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Unknown
Issued 23 December 1985 Resolved
INSTAL APPROVED OIL/WATER SEPERATOR AND DISCHARGE EQUIPMENT AS REQUIRED BY MARPOL 73/78 NO LATER THAN 02 OCTOBER 1986.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Construction/Loadline
Issued 23 December 1985 Resolved
PROVIDE PROTECTIVE GUARD ON GRINDERS IN MECHANIC'S SHOP AND ENGINE ROOM.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Fire Fighting
Issued 23 December 1985 Resolved
PROVIDE APPROVED COMBINATION NOZZEL FOR THE FOLLLOWING FIRE HOSE STATIONS: 12, 15, 16, 23, 28, 29, 32, 35, 41, 45, 46, 47, 48, 50, 51, 52, 56 AND 61. PROVIDE SPANNER WRENCHES AT FIRE HOSE STATIONS: 12, 25, 28, 29, 30, 31, 34,53 AND 55.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Construction/Loadline
Issued 23 December 1985 Resolved
REPLACE BURNED OUT LAMPS AROUND THE PERIMETER OF THE HELO DECK. 46 CFR 108.241.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Construction/Loadline
Issued 23 December 1985 Resolved
MAKE PERMANENT REPAIRS TO SIDE SHELL PLATING BETWEEN FRAMES 15 AND 16 LOCATED TWO FEET BELOW THE DEEP LOADLINE ON THE PORT SIDE.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Documentation
Issued 23 December 1985 Resolved
PROVIDE A COAST GUARD STAMPED APPROVED COPY OF THE HAZARDOUS LOCATION PLAN. REF 46 CFR 107.305.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Fire Fighting
Issued 23 December 1985 Resolved
PROVIDE A STEEL LIFELINE FOR EACH FIREMAN'S OUTFIT. REF 46 CFR 108.497.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Fire Fighting
Issued 23 December 1985 Resolved
PROVIDE FOR ANNUAL SERVICING FOR TWO FIXED HALON SYSTEMS LOCATED IN THE FORWARD PAINT LOCKER AND THE HALON SUPPPORT CONTROL ROOM.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Electrical
Issued 23 December 1985 Resolved
TEST AUTOMATIC START AND AUTO BUS TRANSFER ON EMERGENCY GENERATOR.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Electrical
Issued 23 December 1985 Resolved
MAKE OPERABLE AUTOMATIC START AND TEST AUTOMATIC BUS TRANSFER ON AUXILIARY GENERATOR.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Engineering
Issued 23 December 1985 Resolved
TEST FUEL OIL SERVICE AND TRANSFER PUMP SHUTDOWNS.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Deck/Cargo
Issued 23 December 1985 Resolved
RETHREAD WIRE ROPE FOR MESSENGER LINE ABOVE TENSIONER BOTTLES SO THAT IT DOES NOT RUB AGAINST THE BOTTLES.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Deck/Cargo
Issued 23 December 1985 Resolved
MAKE TENSIONER BOTTLES AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Deck/Cargo
Issued 23 December 1985 Resolved
TEST RELIEF VALVES FOR TENSIONER BOTTLES.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Construction/Loadline
Issued 23 December 1985 Resolved
INSTALL RELIEF VALVES ON HOT WATER TANKS TO RELIEVE LESS THAN 11 PSIG OR MAKE AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Electrical
Issued 23 December 1985 Resolved
INSTALL HEAT RESISTANT SIGHT GLASS ON FUEL OIL OVERFLOW LINES TO SERVICE TANK AND AUXILIARY GENERATOR FUEL TANK.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Construction/Loadline
Issued 23 December 1985 Resolved
INSTALL HEAT RESISTANT SIGHT GLASS ON LUBE OIL TANKS IN RISER COMPRESSOR ROOM.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Construction/Loadline
Issued 23 December 1985 Resolved
INSTALL FLAME SCREENS ON ALL LUBE OIL TANKS.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Electrical
Issued 23 December 1985 Resolved
INSTALL SPRING OR OTHER DEVICE TO FORKLIFT CHANGING CONNECTIONN SO THAT CONNECTION CANNOT FALL TO DECK.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Fire Fighting
Issued 23 December 1985 Resolved
INSTALL A FUEL PUMP SHUT OFF DEVICE AT SECONDARY ACCESS ROUTE TO HELO DECK.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Navigation
Issued 23 December 1985 Resolved
POST MANEUVERING INFORMATION FACT SHEET FOR SHIP, ON BRIDGE, IN ACCORDANCE WITH 33 CFR 164.35.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Lifesaving
Issued 23 December 1985 Resolved
FREE UP FROZEN AFTER MORING BLOCK SLEVE ON NUMBER 2 LIFEBOAT.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Construction/Loadline
Issued 23 December 1985 Resolved
PROVIDE AT LEAST EIGHT CERTIFICATED LIFEBOATMEN ON BOARD VESSEL PER COAST GUARD LETTER OF COMPLIANCE (LOC).
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Construction/Loadline
Issued 23 December 1985 Resolved
POST BEWARE OF TAIL ROTOR SIGN AT EACH HELO DECK ACCESS. 46 CFR 108.653(C).
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Documentation
Issued 23 December 1985 Resolved
SUBMIT THE VESSEL OPERATING MANUAL TO MERCHANT MARINE TECHNICAL OFFICE, 600 S. MAESTRI PL., NEW ORLEANS, LA. 70130, FOR COAST GUARD REVIEW. REF 46 CFR 109.121.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Construction/Loadline
Issued 23 December 1985 Resolved
MARK HELICOPTER REFUELING STATION WITH "WARNING - HELICOPTER FUELING STATION - KEEP LIGHTS AND FIRE AWAY".
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Construction/Loadline
Issued 23 December 1985 Resolved
PLACE STANDBY HORN BATTERY IN LEAD BOX OR OTHER CORROSIAN RESISTANT MATERIAL.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Electrical
Issued 23 December 1985 Resolved
REPAIR EMERGENCY BATTERY LANTERNS IN EMERGENCY GENERATOR ROOM AND AUXILIARYROOM.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Electrical
Issued 23 December 1985 Resolved
REPAIR GENERAL ALARM BELLS IN ENGINE ROOM, MUD PUMP ROOM, SCR ROOM, AUXILIARY GENERATOR ROOM, FORECASTLE DECK, PORT AFT LIFEBOAAT STATION AND MESS ROOM "B".
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985
Electrical
Issued 23 December 1985 Resolved
INSTALL A GENERAL ALARM BELL IN INCINERATOR ROOM.
Condition: Unknown
Due 23 December 1985
Resolved 23 December 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.