MAURY USCG vessel records Sign in
← All vessels

TASMAN SPIRIT

TASMAN SPIRIT is a 1979 tank ship. The Coast Guard has recorded 22 inspections since 1984, most recently in June 1994, along with 25 deficiencies and 1 operational control.

Records from 1984 to 1994. Most recent: inspection, 20 June 1994.

Built
1979
Last inspected
20 June 1994
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7404669 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225008
Flag
PANAMA
—
Maury page id
psix-225008

Inspections, by type

…with no type recorded13
Years with a record 9 calendar years (1984–1994)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 32 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it34926 - Regulatory (Subpart C or D), Net Ton
44116 - Regulatory (Subpart C or D), Gross Ton
87584 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

20 June 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 367779
20 June 1994 Tank Vessel Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1328412
18 November 1992 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 484487
19 October 1992 MARPOL Annex V Examination · Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 937192
17 August 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 534895
31 October 1991 Certificate of Compliance
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 934248
5 June 1991 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 505042
13 October 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 339804
13 October 1990 Certificate of Compliance
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1228575
13 October 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 332940
13 October 1989 Certificate of Compliance
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1347059
27 March 1988 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 322102
27 March 1988 Certificate of Compliance
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1299296
7 July 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016668
13 May 1987 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1026660
9 May 1987 MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1332626
26 April 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 315612
26 April 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1316929
25 February 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 314590
25 February 1987 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1004754
31 December 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 306102
20 October 1984 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 534055

Deficiency record · 25

Deck/Cargo
Issued 20 June 1994 Resolved
STEAM LINE AFT OF MONITOR 6 STBD SIDE IS HOLED. REPAIRS ARE TO BE MADE PRIOR TO THE VESSEL RETURNING TO THE U.S. FROM AN OVERSEAS PORT.
Condition: Unknown
Due 20 June 1994
Resolved 20 June 1994
Accommodation/Occupational Safety
Issued 20 June 1994 Resolved
ALL DOORS P/S SIDE LEADING FROM THE ACCOMMODATIONS SPACES TO THE WEATHER DECKS DO NOT CLOSE OR SEAT PROPERLY. ALL MUST BE MANUALLY CLOSED. ALL ARE TO BE REPAIRED PRIOR TO THE VESSEL RETURNING TO THE U.S. FORM AN OVERSEAS PORT.
Condition: Unknown
Due 20 June 1994
Resolved 20 June 1994
Accommodation/Occupational Safety
Issued 20 June 1994 Resolved
THE AIR INTAKE TO THE A/C IS WASTED. REPAIRS ARE TO BE MADE PRIOR TO THE VESSEL RETURNING TO THE U.S. FROM AN OVERSEAS PORT.
Condition: Unknown
Due 20 June 1994
Resolved 20 June 1994
Electrical
Issued 20 June 1994 Resolved
THE BOTTOM TO ELECTRICAL JUNCTION BOX PORT SIDE AFT OF FIRE MONITOR 5 IS WASTED. REPAIR IS TO BE MADE PRIOR TO THE VESSEL RETURNING TO THE U.S. FROMAN OVERSEAS PORT.
Condition: Unknown
Due 20 June 1994
Resolved 20 June 1994
Deck/Cargo
Issued 20 June 1994 Resolved
THE IGS LINE COMMING OFF THE DECK SEAL HAS A HOLE IN IT JUST FWD OF THE FLANGE. IT HAS BEEN PATCHED WITH RED HAND. REPAIRS ARE TO BE MADE PRIOR TO THE VESSEL RETURNING TO THE U.S. FROM AN OVERSEAS PORT.
Condition: Unknown
Due 20 June 1994
Resolved 20 June 1994
Fire Fighting
Issued 20 June 1994 Resolved
THE EMERGENCY FIRE PUMP PRESSURE GAUGE NEEDS REPLACING. CARD ROTATES WHEN PUMP IS RUNNING.
Condition: Unknown
Due 20 June 1994
Resolved 20 June 1994
Deck/Cargo
Issued 20 June 1994 Resolved
STEAM LINE UNDER FWD FIRE MONITOR 1 IS HOLED. REPARIS ARE TO BE MADE PRIOR TO RETURNING TO THE U.S. FROM AN OVERSEAS PORT.
Condition: Unknown
Due 20 June 1994
Resolved 20 June 1994
Construction/Loadline
Issued 31 October 1991 Resolved
PRIOR TO DEPARTURE NIKISKI, ALASKA GAS FREE AND HAVE MARINE CHEMIST CERTIFYMAIN BALLAST TANK FOR INSPECTION BY USCG MARINE INSPECTOR.
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Fire Fighting
Issued 31 October 1991 Resolved
PROVIDE FOAM ANALYSIS REPORT
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Navigation
Issued 31 October 1991 Resolved
MAKE PERMANENT REPAIRS TO RACAL DECCA MNS20 LORAN/OMEGA/SATNAV RECEIVER
Condition: Unknown
Due 31 October 1991
Resolved 31 October 1991
Documentation
Issued 13 October 1990 Resolved
OIL TRANSFER PROCEDURES DID NOT CONTAIN PRODUCTS BEING TRANSFERED.
Condition: Unknown
Due 13 October 1990
Resolved 13 October 1990
Deck/Cargo
Issued 27 March 1988 Resolved
FLAME SCREENS WERE HOLED AT MOST ULLAGE OPENINGS, BUT WERE REPLACED/REPAIRED AS REQUIRED DURING EXAMINATION.
Condition: Unknown
Due 27 March 1988
Resolved 27 March 1988
Fire Fighting
Issued 13 May 1987 Resolved
FIRE HOSES MISSING FROM TWO ENGINEROOM AND ONE DECK FIRE MAIN STATIONS. ALL STATIONS MUST HAVE HOSES PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Deck/Cargo
Issued 13 May 1987 Resolved
PORT SIDE OF PUMPROOM VENT CLOSURE IS FROZEN. FREE-UP PRIOR TO NEXT ENTRY INTO U.S. WATERS.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Accommodation/Occupational Safety
Issued 13 May 1987 Resolved
CLEAN RAGS, PAINT, THINNER AND SOLVENTS PRIOR TO RETLURN TO U.S. WATERS.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Deck/Cargo
Issued 13 May 1987 Resolved
IGS SYSTEM DID NOT SHUTDOWN FAN FOR IGS SUPPLY UPON LOSS OF SUPPLY TO DECK WATER SEAL [46 CFR 32.53-70(B)(3)] MUST BE REPAIRED PRIOR TO NEXT ENTRY INTO U.S. WATERS.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Deck/Cargo
Issued 13 May 1987 Resolved
#1 CARGO PUMP IMPELLER SHAFT PACKING IS LEAKING CARGO, TO BE REPLACED PRIOR TO RE-ENTRY INTO U.S. WATERS.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Accommodation/Occupational Safety
Issued 13 May 1987 Resolved
MSD HAD NOT HAD CHLORINE ADDED IN SIX MONTHS. ITEM WAS CORRECTED ON THE SPOT, BUT HAD BEEN IN OPERATION IN U.S. WATERS.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Deck/Cargo
Issued 25 February 1987 Resolved
VESSEL IGS SYSTEM CONTROL THAT AUTOMATICALLY SHUTS OFF BLOWERS UPON LOSS OFNORMAL WATER SUPPLY AT THE WATER SEAL NOT OPERATIONAL.
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987
Fire Fighting
Issued 25 February 1987 Resolved
TWO FIRE HOSES MISSING FROM ENGINEERING FIRE STATIONS.
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987
Accommodation/Occupational Safety
Issued 25 February 1987 Resolved
VESSEL'S CREW NOT OPERATING MSD TO MEET THE DESIGN DISCHARGE REQUIREMENTS OF 33 CFR 159.53(B).
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987
Accommodation/Occupational Safety
Issued 25 February 1987 Resolved
CLEAN UP RAGS, PAINT, THINNER AND SOLVENT IN PUMP ROOM PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987
Accommodation/Occupational Safety
Issued 25 February 1987 Resolved
PORT SIDE PUMP ROOM VENT CLOSURE FROZEN. FREE-UP PRIOR TO RETURN TO U.S. PORT.
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987
Deck/Cargo
Issued 25 February 1987 Resolved
NO. 1 CARGO PUMP IMPELLER SHAFT PACKING LEAKING EXCESSIVELY. REPAIR PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987
Unknown
Issued 31 December 1985 Resolved
SUBJ M/V,MISSING CHEMICAL NAME AND CARGO INFORMATION CARD ON THE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 31 December 1985
Resolved 31 December 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.