SINGA SUN is a 1976 freight ship. The Coast Guard has recorded 13 inspections since 1984, most recently in June 1993, along with 13 deficiencies and 1 operational control.
Records from 1984 to 1993. Most recent: inspection, 1 June 1993.
- Built
- 1976
- Last inspected
- 1 June 1993
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7404712 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ELHH5
225010
Flag
PHILIPPINES
—
Maury page id
psix-225010
Inspections, by type
…with no type recorded13
Years with a record
8 calendar years (1984–1993)
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 33 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it8996 - Regulatory (Subpart C or D), Net Ton
16103 - Regulatory (Subpart C or D), Gross Ton
26525 - Dead Weight, Ton
16103 - Regulatory (Subpart C or D), Gross Ton
26525 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
1 June 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 492657
8 October 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 477421
16 July 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 504352
27 January 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 648396
5 November 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 346768
5 November 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1006737
23 April 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 511146
7 June 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 323727
20 May 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 308958
23 October 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 304969
18 October 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 304742
16 May 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 468383
28 August 1984
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 297678
Deficiency record · 13
Accommodation/Occupational Safety
Issued 5 November 1991
Resolved
HOSPITAL SPACE NOT PROPERLY MAINTAINED. WAS USED FOR STORAGE. [ILO-147]_x001C_ _x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 5 November 1991
Resolved
GALLEY NOT IN CLEAN SANITARY CONDITION. [ILO-147]_x001C_ _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 5 November 1991
Resolved
PERSONAL FIRE FIGHTING EQUIPMENT MISSING AN OPERATIONAL ELECTRIC SAFETY LAMP [SOLAS 1974 CH.II-2 REG. 17 PARAGRAPH 1.4]_x001C_ _x001C_ _x001C_
Lifesaving
Issued 5 November 1991
Resolved
MAJORITY OF LIFE JACKETS ONBOARD WERE DRY-ROTTED. [SOLAS 1986 CH.III REG 30PARAGRAPH 2.4]
Navigation
Issued 5 November 1991
Resolved
ADMIRALTY CHART #591 NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINERS CORRECTIONS 1991- 2103,2259,2260,2261._x001C_ _x001C_ _x001C_
Navigation
Issued 5 November 1991
Resolved
ADMIRALTY LIGHT LIST VOL. G 1989 NOT CURRENT EDITION. CURRENT EDITION IS VOL G 1990.
Navigation
Issued 5 November 1991
Resolved
ADMIRALTY COAST PILOT 7th Ed. 1961 NOT CURRENT ADDITION. CURRENT EDITION_x001C_ IS 8th Ed. 1975 WITH SUPPLEMENT 8._x001C_ _x001C_ _x001C_
Lifesaving
Issued 5 November 1991
Resolved
VESSEL REQUIRED TO HAVE 4 LIFEBUOYS WITH SELF-IGNITING LIGHTS ATTATCHED. VESSEL ONLY HAD 2 SELF-IGNITING LIGHTS ONBOARD. [SOLAS 1986 CH. III REG. 7 PARAGRAPH 1.3]_x001C_
Lifesaving
Issued 5 November 1991
Resolved
VESSEL REQUIRED TO HAVE ALL LIFE SAVING APPLIANCES FITTED WITH RETRO- REFLECTIVE MATERIAL. LIFEBUOYS NOT EQUIPPED WITH THIS MATERIAL. [SOLAS 1986CH.III REG. 30 PARAGRAPH 2.7]_x001C_ _x001C_
Lifesaving
Issued 5 November 1991
Resolved
ELECTRICAL EQUIPMENT NOT PROTECTED AND MAINTAINED TO PREVENT DANGER TO PERSONAL ONBOARD. [ILO-147]
Lifesaving
Issued 5 November 1991
Resolved
EQUIPMENT FOR PERSONAL PROTECTION NOT CLEAN AND PROPERLY MAINTAINED. [ILO- 147]_x001C_ _x001C_ _x001C_
Navigation
Issued 18 October 1985
Resolved
33 CFR 88.05: THE VESSEL DID NOT HAVE ON BOARD A COPY OF THE INLAND NAVIGATION RULES.
Accommodation/Occupational Safety
Issued 18 October 1985
Resolved
33 CFR 159.59: THE MARINE SANITATION DEVICE ON BOARD THE VESSEL DID NOT HAVE THE REQUIRED PLACARD.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.