MAURY USCG vessel records Sign in
← All vessels

STELLA TINGAS

STELLA TINGAS is a 1975 freight ship. The Coast Guard has recorded 13 inspections since 1988, most recently in September 2001, along with 13 deficiencies — 1 with no resolution recorded —.

Records from 1988 to 2001. Most recent: inspection, 12 September 2001.

Built
1975
Last inspected
12 September 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7405730 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225028
Flag
LIBERIA
—
Maury page id
psix-225028

Inspections, by type

…with no type recorded13
…past their stated due date1
Years with a record 8 calendar years (1988–2001)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it17383 - Regulatory (Subpart C or D), Gross Ton
28780 - Dead Weight, Ton
10861 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 13

12 September 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 293082
5 March 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 287857
11 January 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 273612
27 December 1999 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 436104
14 April 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 94084
4 January 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 424176
28 December 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 423950
21 August 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 419749
21 August 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 394580
15 July 1996 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 393490
14 July 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 380633
18 April 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 460448
7 October 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 326266

Deficiency record · 13

Unknown
Issued 12 September 2001 No resolution recorded
VESSEL IS FITTED WITH DIRECT DRAINAGE OVERBOARD FROM THE STEERING GEAR SPACE. DISCONTINUE USE OF SYSTEM AND MODIFY TO ALLOW FLOW THROUGH THE OILY WATER SEPERATOR OR INTO BILGE SLOP TANK TO THE SATISFACTION OF CLASS PRIOR TO 12OCT2001. MARPOL 73/78 I/16
Condition: Unknown
Due 12 October 2001 — due date passed with no resolution recorded
Engineering
Issued 5 March 2001 Resolved
SOFT PATCH ON STEAM RETURN PIPING ABOVE S/W COOLING PUMP. REPAIR TO SATISFACTION OF CLASS. (SOLAS 74A I/11)
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Engineering
Issued 5 March 2001 Resolved
FUEL CATALYZER SYSTEM TO BE APPROVED BY CLASS. (SOLAS 74A I/11).
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Accommodation/Occupational Safety
Issued 5 March 2001 Resolved
SEWAGE PIPING AFT OF #1 AIR RECEIVER HAS LEAKS AT FLANGE AND A LEAK AT A REPAIR ON PIPE. REPAIR TO SATISFACTION OF CLASS. (SOLAS 74A I/11)
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Electrical
Issued 5 March 2001 Resolved
FRESH WATER PIPING ON #3 GENERATOR LEAKING AND HOLED. REPAIR TO SATISFACTION OF CLASS. (SOLAS 74A I/11)
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Engineering
Issued 5 March 2001 Resolved
LUBE OIL PURIFIER #2 MISSING DRAINAGE PIPE. REPAIR TO SATISFACTION OF CLASS. (SOLAS 74A I/11)
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Accommodation/Occupational Safety
Issued 5 March 2001 Resolved
MAKE PROPER REPAIRS TO NUMEROUS LEAKS ON MSD PIPING AFT OF MSD. (33 CFR 159)
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Fire Fighting
Issued 27 December 1999 Resolved
The emergency fire pump took 1 hour to start when tested during the boarding in violation of SOLAS 74 (ammended) II-2 Reg. 21. It was then shutoff and restarted several times to prove proper operation. Vessel required to prove proper operation during next U.S.C.G. boarding.
Condition: Unknown
Due 12 January 2000
Resolved 12 January 2000
Navigation
Issued 28 December 1998 Resolved
ALL CHARTS OF THE NEW YORK BAY WERE NOT ON BOARD.AGENT MUST FAX COPY OF RECEIPT PRIOR TO VESSEL DEPARTING PORT.
Condition: Unknown
Due 4 January 1999
Resolved 4 January 1999
Construction/Loadline
Issued 21 August 1996 Resolved
MAKE PERMENANT REPAIRS TO DISCHARGE PIPING IN WAY OF CEMENT PATCH LOCATED THREE FEET AWAY FROM #1 BALLAST PUMP.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Construction/Loadline
Issued 15 July 1996 Resolved
MAKE PERMANENT REPAIRS TO DISCHARGE PIPING IN WAY OF CEMENT PATCH LOCATED THREE FEET FROM #1 BALLAST PUMP.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Navigation
Issued 7 October 1988 Resolved
REQUIRED CHART OF TAMPA BAY #11412 WAS A 1975 EDITION NOT CORRECTED UP TO DATE. NO FOREIGN EQUIVALENT ONBOARD.
Condition: Unknown
Due 1 January 1996
Resolved 21 August 1996
Navigation
Issued 7 October 1988 Resolved
PRE ARRIVAL TESTS NOT LOGGED PRIOR TO PORT ENTRY AS REQUIRED.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995

Ownership record