Records from 1988 to 2001. Most recent: inspection, 12 September 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
12 September 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 293082
5 March 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 287857
11 January 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 273612
27 December 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 436104
14 April 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 94084
4 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 424176
28 December 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 423950
21 August 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 419749
21 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 394580
15 July 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 393490
14 July 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 380633
18 April 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 460448
7 October 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 326266
Unknown
Issued 12 September 2001
No resolution recorded
VESSEL IS FITTED WITH DIRECT DRAINAGE OVERBOARD FROM THE STEERING GEAR SPACE. DISCONTINUE USE OF SYSTEM AND MODIFY TO ALLOW FLOW THROUGH THE OILY WATER SEPERATOR OR INTO BILGE SLOP TANK TO THE SATISFACTION OF CLASS PRIOR TO 12OCT2001. MARPOL 73/78 I/16
Condition: Unknown
Due 12 October 2001 — due date passed with no resolution recorded
Engineering
Issued 5 March 2001
Resolved
SOFT PATCH ON STEAM RETURN PIPING ABOVE S/W COOLING PUMP. REPAIR TO SATISFACTION OF CLASS. (SOLAS 74A I/11)
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Engineering
Issued 5 March 2001
Resolved
FUEL CATALYZER SYSTEM TO BE APPROVED BY CLASS. (SOLAS 74A I/11).
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Accommodation/Occupational Safety
Issued 5 March 2001
Resolved
SEWAGE PIPING AFT OF #1 AIR RECEIVER HAS LEAKS AT FLANGE AND A LEAK AT A REPAIR ON PIPE. REPAIR TO SATISFACTION OF CLASS. (SOLAS 74A I/11)
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Electrical
Issued 5 March 2001
Resolved
FRESH WATER PIPING ON #3 GENERATOR LEAKING AND HOLED. REPAIR TO SATISFACTION OF CLASS. (SOLAS 74A I/11)
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Engineering
Issued 5 March 2001
Resolved
LUBE OIL PURIFIER #2 MISSING DRAINAGE PIPE. REPAIR TO SATISFACTION OF CLASS. (SOLAS 74A I/11)
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Accommodation/Occupational Safety
Issued 5 March 2001
Resolved
MAKE PROPER REPAIRS TO NUMEROUS LEAKS ON MSD PIPING AFT OF MSD. (33 CFR 159)
Condition: Unknown
Due 8 March 2001
Resolved 8 March 2001
Fire Fighting
Issued 27 December 1999
Resolved
The emergency fire pump took 1 hour to start when tested during the boarding in violation of SOLAS 74 (ammended) II-2 Reg. 21. It was then shutoff and restarted several times to prove proper operation. Vessel required to prove proper operation during next U.S.C.G. boarding.
Condition: Unknown
Due 12 January 2000
Resolved 12 January 2000
Navigation
Issued 28 December 1998
Resolved
ALL CHARTS OF THE NEW YORK BAY WERE NOT ON BOARD.AGENT MUST FAX COPY OF RECEIPT PRIOR TO VESSEL DEPARTING PORT.
Condition: Unknown
Due 4 January 1999
Resolved 4 January 1999
Construction/Loadline
Issued 21 August 1996
Resolved
MAKE PERMENANT REPAIRS TO DISCHARGE PIPING IN WAY OF CEMENT PATCH LOCATED THREE FEET AWAY FROM #1 BALLAST PUMP.
Condition: Unknown
Due 10 October 1996
Resolved 10 October 1996
Construction/Loadline
Issued 15 July 1996
Resolved
MAKE PERMANENT REPAIRS TO DISCHARGE PIPING IN WAY OF CEMENT PATCH LOCATED THREE FEET FROM #1 BALLAST PUMP.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Navigation
Issued 7 October 1988
Resolved
REQUIRED CHART OF TAMPA BAY #11412 WAS A 1975 EDITION NOT CORRECTED UP TO DATE. NO FOREIGN EQUIVALENT ONBOARD.
Condition: Unknown
Due 1 January 1996
Resolved 21 August 1996
Navigation
Issued 7 October 1988
Resolved
PRE ARRIVAL TESTS NOT LOGGED PRIOR TO PORT ENTRY AS REQUIRED.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995