← All vessels
IOANNIS K
Freight Ship · General Dry Cargo Ship class · Built 1970s · USCG Heartland District (CGD-H) · Other hulls named IOANNIS K
IOANNIS K is a 1977 freight ship. The Coast Guard has recorded 20 inspections since 1984, most recently in October 2007, along with 158 deficiencies and 1 operational control.
Records from 1984 to 2007. Most recent: inspection, 8 October 2007.
- Built
- 1977
- Last inspected
- 8 October 2007
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 158 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7406497 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225033
Flag
ARGENTINA
—
Maury page id
psix-225033
Inspections, by type
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it12762 - Simplified, Gross Ton
20704 - Dead Weight, Ton
8922 - Simplified, Net Ton
20704 - Dead Weight, Ton
8922 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
8 October 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3075884
8 January 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 373706
2 November 1994
Control Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 863647
23 November 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 355316
30 March 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 534650
20 May 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 343857
11 May 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 337019
11 December 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 473994
4 May 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 330139
16 September 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 325648
12 July 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 324451
12 April 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 537986
14 October 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 319005
8 October 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 311938
16 March 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 307559
13 March 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 525866
8 September 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 304120
13 February 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 465403
9 September 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 297968
31 May 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 471607
Deficiency record · 158
Accommodation/Occupational Safety
Issued 8 January 1995
Resolved
CONTINUE ON REPAIRS OF ACCOMMODATION SPACE TOILETS, SHOWERS AND SINKS. ALL TOILETS SHALL BE PROVIDED WITH AMPLE FLUSH WATER, AVAILABLE AT ALL TIMES AND INDEPENDENTLY CONTROLLABLE AT ALL TIMES AND INDEPENDENTLY CONTROLLABLE.HOT AND COLD FRESH WATER SHALL BE AVAILABLE IN ALL COMMUNAL WASH PLACES.
Deck/Cargo
Issued 8 January 1995
Resolved
RENEW WASTED FOUNDATIONS AND SUPPORTING BRACKETS TO PORT AND STARBOARD ANCHOR WINDLASS POWER UNIT.
Deck/Cargo
Issued 8 January 1995
Resolved
LOCATE AND REPAIR HYDRAULIC OIL LEAK TO STARBOARD ANCHOR WINDLESS POWER UNIT.
Electrical
Issued 8 January 1995
Resolved
REPAIR OIL LEAK TO NO.3 SHIP SERVICE GENERATOR.
Engineering
Issued 8 January 1995
Resolved
RENEW DETERIORATED SALT WATER COOLING PIPING LOCATED ABOVE OILY-WATER SEPERATOR IN ENGINE ROOM. PIPING SUPPLIES COOLING WATER TO REFRIGERATOR COMPRESSORS.
Engineering
Issued 8 January 1995
Resolved
REPAIR/RENEW DAMAGED ENGINE ROOM MAIN VENTILATION TRUNK.
Accommodation/Occupational Safety
Issued 8 January 1995
Resolved
REPAIR/RENEW SANITARY WATER PUMPS/MOTORS IN ENGINE ROOM.
Accommodation/Occupational Safety
Issued 8 January 1995
Resolved
RENEW DETERIORATED TYPE II MARINE SANITATION DEVICE. UNITS INTERNAL STRUCTURAL MEMBERS ARE DETERIORATED. SYSTEM IS PRESENTLY INSTALLED IS NOT FUNCTIONING IN ACCORDANCE WITH MANUFACTURES RECOMMENDATIONS.
Navigation
Issued 8 January 1995
Resolved
MANEUVERING INFORMATION FACT SHEET IS MISSING THE WARNING STATEMENT AND ALSO MISSING IS THE MANEUVERING INFORMATION FOR NORMAL BALLAST AND NORMAL LOAD CONDITIONS.
Unknown
Issued 8 January 1995
Resolved
NO PRE-ARRIVAL TEST WAS LOGGED IN THE SHIP'S LOG BOOK.
Electrical
Issued 8 January 1995
Resolved
LIGHT FIXTURES THROUGHT THE VESSEL SHALL BE ADEQUATELY PROTECTED TO PREVENTBREAKAGE OF THE BULBS OR THEIR COMING IN CONTACT WITH COMBUSTIBLE MATERIALS.
Documentation
Issued 8 January 1995
Resolved
PROVIDE ONBOARD VESSEL INSTRUCTIONS FOR MAINTENANCE OF ALL LIFESAVING APPLIANCES IN ACCORDANCE WITH SOLAS 74 AMENDED III/19.3 & 52
Electrical
Issued 8 January 1995
Resolved
MAKE PERMANENT REPAIRS TO DAMAGED/HOLED/SOFT PATCHED INJECTOR COOLING PIPING TO NO 3 AND NO 1 SHIP SERVICE GENERATOR. ITEM SHALL BE CORRECETED PRIOR TO ENTRY TO NEXT U.S. PORT TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD AND CLASS SOCIETY SURVEYOR
Engineering
Issued 8 January 1995
Resolved
PROVIDE AND PROVE OPERATION OF FUEL OIL SUCTION PIPE VALVE FROM EMERGENCY FIRE PUMP DAILY SERVICE TANK THATS CAPABLE OF BEING CLOSED FROM OUTSIDE THESPACE THE TANK IS LOCATED IN THE EVENT OF A FIRE ARISING. ITEM SHALL BE CORRECTED PRIOR TO ENTRY OF NEXT U.S. PORT.
Lifesaving
Issued 8 January 1995
Resolved
PROVE OPERATION OF LIMIT SWITCHES TO PORT AND STARBOARDD LIFEBOAT DAVITS ONCE MECHANICAL MEANS TO RETRIEVE LIFEBOAT IS RESTORED.
Engineering
Issued 8 January 1995
Resolved
INSTALL GUARDS OR FENCING AROUND ROTATING AND HOT PARTS OF MACHINERY AND EQUIPMENT THROUGHOUT VESSEL TO PREVENT INJURY TO PERSONNEL.
Electrical
Issued 8 January 1995
Resolved
REMOVE/REPAIR EXPOSED ELECTRICAL WIRING AND OTHER ELECTRICAL EQUIPMENT THROUGHOUT MACHINERY AND ACCOMMODATION SPACES TO ENSURE THEY ARE PROTECTED AND MAINTAINED TO PREVENT DANGER TO PEOPLE ONBOARD THE VESSEL.
Engineering
Issued 8 January 1995
Resolved
VENT CLOSURES ON PORT/STARBOARD SIDES OF MAIN DECK TO ENGINEROOM INOPERABLE
Construction/Loadline
Issued 8 January 1995
Resolved
Prove proper operation of bilge and ballast systems to include proper labeling of manifolds, pump operation, compliance with ballast and stability information.
Fire Fighting
Issued 8 January 1995
Resolved
PROVIDE FIRE EXTINGUISHER BRACKET ON AIR CONDITIONER COMPARTMENT
Accommodation/Occupational Safety
Issued 8 January 1995
Resolved
RENEW VENT LOCATED ON AFT POOP DECK.
Construction/Loadline
Issued 8 January 1995
Resolved
Remove rigged submersible pumps from cargo holds, ballast tanks, etc. proveforepeak can be properly ballasted, remaove electrical splice into panel board.
Construction/Loadline
Issued 8 January 1995
Resolved
REPAIR HOLED HATCH COVER TO ROPE LOCKER, RENEW MISSING DOGGING MECHANISM
Accommodation/Occupational Safety
Issued 8 January 1995
Resolved
INSTALL SECURING DEVICE TO VENT CLOSURE ON AFT POOP DECK.
Fire Fighting
Issued 8 January 1995
Resolved
Make proper repairs to the firemain system, piping is wasted and has soft patches.
Deck/Cargo
Issued 8 January 1995
Resolved
REPAIR LEAKS TO HYDRAULIC POWER UNITS FOR CRANES AND REMOVE OIL RESIDUES FROM DECK.
Fire Fighting
Issued 8 January 1995
Resolved
Prove proper operation of main fire pump including gauge operation and relief valve.
Fire Fighting
Issued 8 January 1995
Resolved
RENEW DETERIORATED ANGEL STOP VALVE INSTALLED ON THE DISCHARGE SIDE OF EMERGENCY FIRE PUMP.
Fire Fighting
Issued 8 January 1995
Resolved
Repair or replace leaking fire hydrants.
Accommodation/Occupational Safety
Issued 8 January 1995
Resolved
RENEW WASTED STEPS TO ANCHOR WINDLASS.
Lifesaving
Issued 8 January 1995
Resolved
FORCASTLE LIFERAFT CONTAINER CRACKED AND IN NEED OF REPAIR OR REPLACEMENT.
Fire Fighting
Issued 8 January 1995
Resolved
INSTALL APPROVED FIXED FIRE SUPPRESION SYSTEM IN PAINT LOCKER
Lifesaving
Issued 8 January 1995
Resolved
INSTALL HYDROSTATIC RELEASES TO ALL LIFERAFTS SO THAT MANUAL RELEASE IS FACING OUTBAORD OF LIFERAFT
Navigation
Issued 8 January 1995
Resolved
PROVIDE ADEQUATE SHIPS BELL.
Fire Fighting
Issued 8 January 1995
Resolved
Prove proper operation of emergency fire pump, diesel engine is inoperational, fuel tank, piping improper, machinery gaurds are missing.
Fire Fighting
Issued 8 January 1995
Resolved
RENEW LATERN FOR MAIN DECK FIREMAN OUTFIT ALONG WITH NEW TENDING LINE
Engineering
Issued 8 January 1995
Resolved
Repair or replace fuel tanks. Diesel day tank for emergency generator are wasted through and are leaking into bilge.
Engineering
Issued 8 January 1995
Resolved
PROVIDE SHOVEL FOR BOILER SAND BOX
Electrical
Issued 8 January 1995
Resolved
RENEW INJECTOR COOLING PIPING TO NO3 AND NO1 SHIPS SERVICE GENERATORS
Deck/Cargo
Issued 8 January 1995
Resolved
PROVIDE COVERS FOR ROTATING MACHINARY IN HYDRULIC PUMP ROOM
Lifesaving
Issued 8 January 1995
Resolved
Port lifeboat should be checked for the presence of water in the foam and the existing repairs to the starboard inboard step be redone.
Engineering
Issued 8 January 1995
Resolved
RELAY HOT PIPING IN ENGINE ROOM
Lifesaving
Issued 8 January 1995
Resolved
REPAIR STARBOARD LIFEBOAT HULL STERN.
Engineering
Issued 8 January 1995
Resolved
REPAIR POWER VENTILATOR AND CLOSURE DEVICE LOCATED ON AFT POOP DECK.
Lifesaving
Issued 8 January 1995
Resolved
Repair holed motor cover on port lifeboat.
Engineering
Issued 8 January 1995
Resolved
CLEAN BILGES IN FUEL OIL PURIFIER ROOM OF ALL OIL RESIDUES
Lifesaving
Issued 8 January 1995
Resolved
provide and install exhaust lagging on port lifeboat engine exhaust were exposed to crew.
Engineering
Issued 8 January 1995
Resolved
REMOVE EQUIPMENT/SUPPLIES FROM ENGINE ROOM ACCESS/ESCAPE TUNNEL
Lifesaving
Issued 8 January 1995
Resolved
Extend the port lifeboat engine cover to include the transmission.
Lifesaving
Issued 8 January 1995
Resolved
PROVE OPRERATION OF GENERAL ALARM BELLS.
Fire Fighting
Issued 8 January 1995
Resolved
CONDUCT A FIRE DRILL IN THE PRECENCE OF COAST GUARD INSPECTOR
Lifesaving
Issued 8 January 1995
Resolved
INSTALL KEEL BLOCKS TTTO PORT LIFEBOAT DAVIT.
Lifesaving
Issued 8 January 1995
Resolved
REPAIR PORT LIFEBOAT DRAIN PLUG
Lifesaving
Issued 8 January 1995
Resolved
REPAIR PORT LIFEBOAT HULL
Construction/Loadline
Issued 8 January 1995
Resolved
Repair all watertight doors on main house leading to accommodation areas sothey seal properly.
Lifesaving
Issued 8 January 1995
Resolved
Provide and install safety placard and instructions for lifeboats and liferafts at launching stations.
Navigation
Issued 8 January 1995
Resolved
Prove proper operation of masthead and anchor lights and that they are proper type. i.e. not household bulbs. this is in addition to item for running lights.
Electrical
Issued 8 January 1995
Resolved
Prove proper operation of emergency lighting on bridge and steering gear flat.
Accommodation/Occupational Safety
Issued 8 January 1995
Resolved
RENEW FRESH WATER VENTS LOCATED PORT SIDE AFT POOP DECK
Fire Fighting
Issued 8 January 1995
Resolved
INSTALL CLOSURE DEVICE FOR NATURAL VENT TO CO2 ROOM LOCATED ON MAIN DECK
Construction/Loadline
Issued 8 January 1995
Resolved
RENEW HOLED BULKHEAD TO CO2 ROOM LOCATED ON MAINDECK BELOW STEP TO ENTRANCEOF CO2 ROOM.
Construction/Loadline
Issued 8 January 1995
Resolved
Remove fuel oil sludge from forward ballast pump room.
Deck/Cargo
Issued 8 January 1995
Resolved
RENEW ACCESS COVERS FOR CARGO HOLD POWER VENTILATORS LOCATED ON MAIN DECK AND ENSURE THEY ARE WATERTIGHT.
Construction/Loadline
Issued 8 January 1995
Resolved
Repair/replace bilge deck plates, steps, ladders in forward ballast pump room as necessary.
Navigation
Issued 8 January 1995
Resolved
PROVE OPERATION OF MAGNATIC COMPASS FOR EACH LIFEBOAT
Accommodation/Occupational Safety
Issued 8 January 1995
Resolved
ALL TOILETS SHALL BE OPERABLE WITH AMPLE FLUSH WATER AVALIBLE AT ALL TIMES
Documentation
Issued 8 January 1995
Resolved
provide proof that the vessel is within class with Bureau Veritas or other recognized society.
Accommodation/Occupational Safety
Issued 8 January 1995
Resolved
HOT AND COLD WATER SHALL BE AVALIBLE FOR ALL COMMON WASH AREAS
Documentation
Issued 8 January 1995
Resolved
Provide safe manning document issued by the flag administration.
Accommodation/Occupational Safety
Issued 8 January 1995
Resolved
DECKS, HOLDS, COMPARTMENTS, AND HOLD ACCESS AREAS WHERE PEOPLE PASS SHALL BE ADEQUATELY LITE,
Fire Fighting
Issued 8 January 1995
Resolved
Hydrostatically test all fire hoses in the presence of a U.S. Coast Guard inspector or boarding officer. Numerous fire hoses placed on fire stations throughout vessel show signs of wear.
Fire Fighting
Issued 8 January 1995
Resolved
Provide and mark all fire stations, in accordance with the vessels fire andsafety plan.
Fire Fighting
Issued 8 January 1995
Resolved
Repair broken fire main valve on main deck port side forward of midships.
Construction/Loadline
Issued 8 January 1995
Resolved
Secure deck plates in machinery space's lower level.
Accommodation/Occupational Safety
Issued 8 January 1995
Resolved
Repair step rungs 3 & 4 on ladder leading to forcastle starboard side.
Accommodation/Occupational Safety
Issued 8 January 1995
Resolved
Repair all broken hand rail on main deck and ladder from main deck port side aft.
Navigation
Issued 8 January 1995
Resolved
Repair telephone bell for aft steering station.
Navigation
Issued 8 January 1995
Resolved
Remove and install proper bridge port and starboard running lights.
Deck/Cargo
Issued 8 January 1995
Resolved
REPAIR/RENEW DETERIORATED FIRE DAMPER SECURING DEVICES AND STOPPING DEVICESON ALL CARGO HOLD VENTILATORS. ITEM SHALL BE CORRECTED PRIOR TO ENTRY TO NEXT U.S. PORT TO THE SATISFACTION OF THE ATTENDING CLASS SOCIETY SURVEYOR WITH REPORT MAINTAINED ON BOARD VESSEL.
Fire Fighting
Issued 8 January 1995
Resolved
INSTALL AND PROVE OPERATION OF VENTILATION SYSTEM TO EMERGENCY FIRE PUMP COMPARTMENT.
Electrical
Issued 8 January 1995
Resolved
REPAIR/RENEW ELECTRICAL CONTROLLERS FOR CRANE HYDRAULIC POWER UNITS. STOP/START AND AMP GUAGES WORK INTERMITTENTLY.
Deck/Cargo
Issued 8 January 1995
Resolved
REPAIR/RENEW HOLED/DETERIORATED MUSHROOM VENT COVERS TO ALL CARGO HOLD POWER VENTILATORS LOCATED ON MAIN DECK.
Construction/Loadline
Issued 8 January 1995
Resolved
RENEW/REPAIR KNIFE EDGE TO WATERTIGHT DOOR THAT LEADS TO CO2 COMPARTMENT ONMAIN DECK.
Engineering
Issued 8 January 1995
Resolved
RENEW DETERIORATED FLAME SCREEN TO FUEL OIL TANK VENT LOCATED ON STARBOARD SIDE MAIN DECK.
Engineering
Issued 8 January 1995
Resolved
RENEW HOLED AND DETERIORATED FUEL OIL TANK VENT PIPING TO NO.4 DOUBLE BOTTOM TANK PORT SIDE BETWEEN NO.3 AND NO.4 CARGO HOLDS.
Deck/Cargo
Issued 8 January 1995
Resolved
REPAIR AND PROVE OPERATION OF ALL POWER VENTILATORS LOCATED ON ALL WEATHERDECKS. ITEM SHALL BE CORRECTED TO THE SATISFACTION OF THE ATTENDING USCG AND CLASS SOCIETY SURVEYOR.
Lifesaving
Issued 8 January 1995
Resolved
RENEW AND PROVE OPERATION OF LIGHTING FOR ILLUMINATING THE STOWAGE POSITIONOF LIFERAFTS AND LIFEBOATS. ITEM SHALL BE COMPLETED PRIOR TO ENTRY TO NEXT U.S. PORT AND TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Navigation
Issued 8 January 1995
Resolved
PROVIDE DOCUMENTATION FROM FLAG ADMINISTRATION THAT THE NEWLY INSTALLED NAVIGATION LIGHTS ONBOARD VESSEL COMPLY WITH ANNEX II, PART 8 AS REFERENCEDIN PART C RULE 20 OF THE 1972 COLREGS. LIGHTS MUST ALSO MEET THE MINIMUM VISIBILITY REQUIREMENTS OF PART C RULE 22 OF 1972 COLREGS.
Construction/Loadline
Issued 8 January 1995
Resolved
CONTINUE TO REPAIR ALL VENTILATION CLOSURES THROUGHOUT VESSEL TO ENSURE AN EFFICIENT THROUGHOUT VESSEL TO ENSURE AN EFFICIENT WEATHERTIGHT CLOSURE. MANY CLOSURES ARE STILL EITHER DETERIORATED, FROZEN, MISSING CLOSURE MECHANISMS, AND OR MISSING SECURING DEVICES.
Construction/Loadline
Issued 8 January 1995
Resolved
Repair water tight door from machinery space's to accomodation space's.
Lifesaving
Issued 8 January 1995
Resolved
PROVIDE TRAIINING MANUALS COMPLYING WITH THE REQUIREMENTS OF SOLAS CHAPTER III REGULATION 51 AMENDED FOR EACH CREW MESSROOM AND RECREATION ROOM OR IN EACH CREW CABIN. PRESENT TRAINING MANUALS DO NOT REFLECT ACTUAL EQUIPMENT INSTALLED ON THE IOANNIS K.
Engineering
Issued 8 January 1995
Resolved
PROVIDE UP TO DATE OIL TRANSFER PROCEDURES TO INCLUDE: A LIST OF PRODUCTS TRANSFERRED, PROCEDURES AND DUTY ASSIGNMENTS FOR TENDING THE VESSELS MOORING DURING TRANSFER OF OIL AND PROCEDURES FOR TOPPING OFF TANKS IN ACCORDANCE WITH 33 C.F.R. 155.750.
Navigation
Issued 8 January 1995
Resolved
PROVIDE ONBOARD VESSEL A CURRENT DEVIATION TABLE, GRAPH OR COMPASS COMPARISON RECORD.
Accommodation/Occupational Safety
Issued 8 January 1995
Resolved
PROVIDE A FACILITY FOR WASHING AND DRYING CLOTHES IN A SPACE SEPERATE FROM SLEEPING ROOMS AND MESS ROOMS.
Engineering
Issued 8 January 1995
Resolved
STEAM PIPES, EXHAUST PIPES AND FITTING WHICH BY THEIR LOCATION AND TEMPERATURE OR PRESSURE PRESENT A HAZARD SHALL BE ADEQUATELY INSULATED OR OTHERWISE PROTECTED.
Engineering
Issued 8 January 1995
Resolved
PROVIDE DOCUMENTATION THAT THE OILY-WATER SEPARATIN EQUIPMENT IS APPROVED UNDER 46 C.F.R. 162.050 WITH APPROVAL # AFFIXED TO THE UNIT OR LISTED IN CURRENT IMO MEPC CIRCULAR SUMMARY OF MARPOL 73/78 APPROVED EQUIPMENT.
Engineering
Issued 8 January 1995
Resolved
REPAIR AND PROVE OPERATION OF NEWLY INSTALLED 15PPM OIL CONTENT METER AND THREE WAY VALVE PRIOR TO DEPARTURE FROM THE PORT OF NEW ORLEANS, LA. BILGE PUMP/OWS OUERBOARD DISCHARGE VALVE SHALL BE LOCKED IN THE CLOSED POSITION TO PREVENT THE ACCIDENTAL DISCHARGE OF OILY WASTE IN U.S. WATERS.
Engineering
Issued 8 January 1995
Resolved
REPAIR HOLED/WASTED ENGINE ROOM ENGINE EXHAUST CASING LOCATED ON UPPER BRIDGE DECK.
Construction/Loadline
Issued 8 January 1995
Resolved
PROVE OPERATION OF POWER VENTILATOR LOCATED IN CO2 COOMPARTMENT ON MAIN DECK.
Engineering
Issued 8 January 1995
Resolved
PROVE OPERATION OF SAFETY DEVICES ON AUX BOILERS
Lifesaving
Issued 8 January 1995
Resolved
PROVIDE EACH SIDE OF SHIP WITH A MANUALLY ACTIVATED RADIO BEACON.
Lifesaving
Issued 8 January 1995
Resolved
INSTALL MUSTER LIST IN ENGINE ROOM.
Lifesaving
Issued 8 January 1995
Resolved
CONDUCT ABANDON SHIP DRILL IN THE PRESENCE OF COAST GUARD INSPECTOR.
Lifesaving
Issued 8 January 1995
Resolved
PROVIDE EVIDENCE THAT LIFEBOAT DAVIT FALLS HAVE BEEN TURNED AT ENTERVALS OFNOT LESS THAT 30 MONTHS
Documentation
Issued 8 January 1995
Resolved
PROVIDE LOGBOOK ENTRIES FOR THE FOLLOWING TEST. PRE-ARRIVAL/DEPARTURE, STEERING GEAR, EMERGENCY STEERING, ABONDON SHIP, ECT
Documentation
Issued 8 January 1995
Resolved
PROVIDE LETTER FROM FLAGSTATE STATING THE THE EXCEPT FOREIGN LICENCE
Fire Fighting
Issued 8 January 1995
Resolved
RENEW DAMAGED MALE HOSE THREADS ON FIRE HOSE AT #2 FIRE STATION
Construction/Loadline
Issued 8 January 1995
Resolved
RENEW ENGINE ROOM ACCESS HATCH COVERS LOCATED ON AFT BRIDGE
Fire Fighting
Issued 8 January 1995
Resolved
Prove operation of the means for stopping ventillating fans serving machinery spaces and for closing all door ways, ventilators, annular spacesaround funnels and other openings to such spaces. These means shall be capable of being operated from outside such space in case of fire.
Construction/Loadline
Issued 8 January 1995
Resolved
RENEW WASTED BULKHEADS ON 2ND DECK
Engineering
Issued 8 January 1995
Resolved
PLACE GUARDS AROUND ROTATING AND HOT PARTS
Engineering
Issued 8 January 1995
Resolved
Prove operation of remote controls, situated outside the space concerned for machinery.
Lifesaving
Issued 8 January 1995
Resolved
Provide 40 life preservers with approved lights and whistles.
Fire Fighting
Issued 8 January 1995
Resolved
PROVIDE SERVICEING REPORT OF ALL PORTABLE FIRE EXTINQUISHERS ON BOARD VESSEL
Lifesaving
Issued 8 January 1995
Resolved
INSTALL WEEK LINKS ON ALL LIFERAFT SEAPAINTERS
Electrical
Issued 8 January 1995
Resolved
Prove operation of daylight signalling lamp which shall not be solely dependent upon the ships main source of electrical power.
Navigation
Issued 8 January 1995
Resolved
REPAIR LEEKS IN STEERING SYSTEM AND CLEAN OIL RESIDUES FROM STEERING PUMP ROOM
Electrical
Issued 8 January 1995
Resolved
ISOLATE ELECTRICAL GROUND NOTED ON MAIN SWITHBOARD.
Navigation
Issued 8 January 1995
Resolved
Provide dayshapes as required by Rule 30 Part C of the COLREGS 1972. Renew 3 black ball shapes and provide 1 diamond shape.
Engineering
Issued 8 January 1995
Resolved
REPAIR FUEL OIL LEAK TO FUEL OIL PUMP FOR AUX BOILERS
Engineering
Issued 8 January 1995
Resolved
Provide standard discharge connection in accordance with regulation 19 of flag administration issued IOPP certificate.
Documentation
Issued 8 January 1995
Resolved
PROVIDE EVIDENCE OF LOG ENTRIES INDICATING HOW THE CREW DISCHARGED GARBAGE.
Electrical
Issued 8 January 1995
Resolved
SERVICE ALL BATTERIES IN BATTERY ROOM, NOTED LOW WATER, LOW SPECIFIC GRAVITY.
Fire Fighting
Issued 8 January 1995
Resolved
provide up to date fire control plan depecting fire alarms, detecting systems, fire extinguishers and the ventilating control positions, the postion of dampers and identification numbers of the ventilating fans serving each section.
Electrical
Issued 8 January 1995
Resolved
REPAIR MUSHROOM VENT TO BATTERY ROOM
Lifesaving
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, SECURE DECK PLATING IN MACHINERY SPACE.
Electrical
Issued 2 November 1994
Resolved
PRIOR TO NEXT U.S. VOYAGE, INSTALL LIGHT COVERS FOR ALL Port LIGHTS exposedTO HAZARDOUS AREAS (i.e., PAINT LOCKER, MACHINERY SPACE, BATTERY ROOM).
Lifesaving
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, REMOVE EXCESS OIL FROM ENGINE ROOM BILGE AND CLEAN SAME.
Fire Fighting
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, SHOW PROOF OF SERVICING FOR PORTABLE FIRE EXTINGUISHERSOR SERVICE SAME.
Lifesaving
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, REPLACE EMERGENCY TOOL KIT REQUIRED FOR MOTORIZED LIFEBOAT.
Fire Fighting
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, INSTALL FIRE DAMPERS IN VENT DUCTS IN PAINT LOCKER.
Construction/Loadline
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, DEMONSTRATE PROPER OPERATION OF OILY WATER SEPARATOR TO15 PPM.
Documentation
Issued 2 November 1994
Resolved
PROVIDE CREW MEMBERS I.A.W. SAFE MANNING DOCUMENT PRIOR TO DEPARTURE.
Documentation
Issued 2 November 1994
Resolved
IF AUTOMATION SYSTEM IS NOT OPERATING PROPERLY THE ENGINE ROOM MUST BE MANNED BY LICENSED OFFICERS. PROVE PRIOR TO DEPARTURE.
Fire Fighting
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, DEMONSTRATE PROPER OPERATION OF MAIN FIRE PUMP AND HYDRO TEST ALL FIRE HOSES.
Lifesaving
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, SERVICE OR REPLACE FORWARD LIFERAFT AND PROPERLY INSTALL.
Lifesaving
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, PROPERLY Install RAFTS including WEAKLINKS AND remove OBSTRUCTIONS.
Fire Fighting
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, DEMONSTRATE PROPER OPERATION/PRESSURE OF EMERGENCY FIREPUMP.
Fire Fighting
Issued 2 November 1994
Resolved
INSTALL FIRE Extinquishing SYSTEM IN PAINT LOCKER.
Lifesaving
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, PROPERLY STOW ALL PAINT SOLVENTS AND THINNERS FROM THROUGHOUT THE VESSEL TO THE PAINT LOCKER.
Construction/Loadline
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, DEMONSTRATE THAT ALL WATER-TIGHT DOORS OPERATE AND SEALPROPERLY.
Construction/Loadline
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, DEMONSTRATE PROPER CLOSURE OF ALL DOORS BETWEEN THE MACHINERY SPACES AND ACCOMODATION SPACES.
Fire Fighting
Issued 2 November 1994
Resolved
PRIOR TO NEXT U.S. VOYAGE, CLEARLY MARK ALL FIRE STATIONS AND STATION EQUIPMENT ON SOLAS FIRE/SAFETY PLAN.
Electrical
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, REPAIR BROKEN/MISSING SWITCHES ON ALL CONTROL BOXES ANDREPAIR ALL FRAYED/BROKEN/EXPOSED WIRING.
Fire Fighting
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, REPAIR/REPLACE ALL REQUIRED EQUIPMENT FROM THE EMERGENCY GEAR LOCKER.
Fire Fighting
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, REPLACE ALL BROKEN/MISSING HAND WHEELS ON FIRE STATION VALVES.
Lifesaving
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, REPAIR AND DEMONSTRATE EMERGENCY LIGHTING FOR LIFEBOAT STATIONS.
Navigation
Issued 2 November 1994
Resolved
Demonstrate means OF COMMUNICATION BETWEEN BRIDGE AND EMERGENCY STEERING STATION.
Navigation
Issued 2 November 1994
Resolved
PRIOR TO DEPARTURE, REPLACE MISSING EPIRB ON BRIDGE WING.
Fire Fighting
Issued 20 May 1991
Resolved
CG BOARDING OFFICERS DISCOVERED ONE OF THE TWO FIRE FIGHTING PUMPS WAS_x001C_ INOPERABLE DUE TO MISSING INJECTORS AS REQUIRED BY SOLAS 65.
Documentation
Issued 20 May 1991
Resolved
OIL TRANSFER PROCEDURES WERE LACKING THE INFORMATION REQUIRED BY_x001C_ 33CFR 155.750,(a)(2(i),(a)(2)(iii), (a)(5), (a)(6),(a)(7).
Engineering
Issued 20 May 1991
Resolved
CG BOARDING OFFICERS FOUND THE OILY WATER SEPARATOR TO BE INOPERABLE DUE_x001C_ TO A FAULTY SENSOR, AS REQUIRED BY 33CFR 155.370(a)(2).
Deck/Cargo
Issued 20 May 1991
Resolved
UPON INSPECTION OF PINE OIL TANKS THE BOARDING OFFICERS NOTICED THE TANKS WERE LACKING THE APPROPRIATE PLACARDS AS REQUIRED BY 49CFR 172.504 TABLE 2.
Documentation
Issued 4 May 1989
Resolved
49CFR176.30(A) THE VESSELS DANGEROUS CARGO MANIFEST CONTAINED MATERIAL WHICH IS NOT SUBJECT TO THE REQUIREMENTS OF 49CFR OR THE IMDG CODE. AUTHORITY CITE: 49USC1804 PENALTY CITE: 49USC1809
Documentation
Issued 4 May 1989
Resolved
49CFR176.30(A)(1) THE VESSELS DANGEROUS CARGO MANIFEST DID NOT CONTAIN THE VESSELS OFFICIAL NUMBER OR CALL SIGN. AUTHORITY CITE: 49USC1804 PENALTY CITE: 49USC1809
Documentation
Issued 8 October 1986
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE.
Documentation
Issued 8 October 1986
Resolved
DANGEROUS CARGO MANIFEST IMPROPERLY PREPARED.
Navigation
Issued 9 September 1984
Resolved
SECOND RADAR INOPERATIVE (RADAR WAS OPERATIVE BEFORE THIS DOCUMENT WAS COMPLETED)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.