← All vessels
BUDI HUDA
BUDI HUDA is a 1976 freight ship. The Coast Guard has recorded 22 inspections since 1985, most recently in May 1996, along with 46 deficiencies and 2 operational controls.
Records from 1985 to 1996. Most recent: operational control imposed, 9 May 1996.
- Built
- 1976
- Last inspected
- 9 May 1996
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 46 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7407001 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225037
Flag
MALTA
—
Maury page id
psix-225037
Inspections, by type
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it30915 - Regulatory (Subpart C or D), Gross Ton
50200 - Dead Weight, Ton
22081 - Regulatory (Subpart C or D), Net Ton
50200 - Dead Weight, Ton
22081 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
9 May 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 390900
18 September 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 382782
24 April 1995
Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 377649
18 December 1994
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 373485
10 December 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 373194
9 December 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1145157
11 August 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 537863
11 August 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 865616
8 June 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 367288
8 June 1994
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1324646
13 February 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 364439
21 May 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 350846
18 January 1992
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 348225
6 August 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 345156
2 January 1991
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 524879
22 September 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 339415
23 August 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 325238
5 August 1987
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 317809
2 March 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 509305
22 September 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 311607
22 July 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 303201
26 February 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 466028
Deficiency record · 46
Accommodation/Occupational Safety
Issued 9 May 1996
Resolved
RENEW MISSING NATURAL VENT. CLOSURES LOCATED STBD SIDE ON BRIDGE DECK._x001C_ SOLAS 60 II/47(a)
Documentation
Issued 9 May 1996
Resolved
PROVIDE ONBOARD VESSEL OIL TRANSFER PROCEDURES THAT COMPLY WITH THE REQUIREMENTS OF 33 C.F.R. 155.750., PROCEDURES MUST BE ONBOARD PRIOR TO ANYBUNKERING OR OTHER OIL TRANSFERS_x001C_ 33 C.F.R. 155.720.
Lifesaving
Issued 9 May 1996
Resolved
Renew retro-reflective material to port and stbd lifeboats. Lifeboats shallbe fitted with retro-reflective material in accordance with_x001C_ Solas 74 amended III/30.2.7 and IMO Resolution A.658(16)
Lifesaving
Issued 9 May 1996
Resolved
RENEW ALL DEFECTIVE RING LIFEBUOYS. PROVIDE 14 RING LIFEBUOYS ON STATION INACCORDANCE WITH FIRE CONTROL PLAN IN SERVICABLE CONDITION AND AVAILABLE FORIMMEDIATE USE._x001C_ SOLAS 74 AMENDED III/19.2
Lifesaving
Issued 9 May 1996
Resolved
RENEW DEFECTIVE WATERLIGHTS TO RING LIFEBUOYS. PROVIDE 7 WATERLIGHTS ATTACHED TO RING LIFEBUOYS IN ACCORDANCE WITH FIRE CONTROL PLAN THAT ARE INA SERVICABLE CONDITION AND AVAILABLE FOR IMMEDIATE USE._x001C_ SOLAS 74 AMENDED III/19.2
Fire Fighting
Issued 9 May 1996
Resolved
CLEAN OIL SOAKED SCREENS LOCATED IN THE GAYLORD VENT IN THE GALLEY
Deck/Cargo
Issued 9 May 1996
Resolved
PROVIDE PLUGS FOR ALL FUEL OIL/LUBE OIL CONTAINMENTS ON THE MAIN DECK
Fire Fighting
Issued 9 May 1996
Resolved
REPAIR INOPERABLE SMOKE DETECTION SYSTEM IN THE ENGINE ROOM_x001C_ SOLAS 74 AMENDED II-2/21
Deck/Cargo
Issued 9 May 1996
Resolved
RENEW AS ORIGINAL DETERIORATED 100 PSI AIR SERVICE PIPE LOCATED AFT OF #6 CARGO HOLD
Fire Fighting
Issued 9 May 1996
Resolved
RENEW/REPAIR DETERIORATED COVER FOR THE CO2 RELEASE BOX LOCATED STBD SIDE OF #4 CARGO HOLD
Construction/Loadline
Issued 9 May 1996
Resolved
RENEW DETERIORATED GASKET TO ACCESS TRUNK LOCATED BETWEEN #3 AND #4 CARGO HOLD
Construction/Loadline
Issued 9 May 1996
Resolved
RENEW DETERIORATED GASKET TO ACCESS TRUNK LOCATED BETWEEN #1 AND #2 CARGO HOLD
Deck/Cargo
Issued 9 May 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER PIPING TO STBD ANCHOR WASH
Deck/Cargo
Issued 9 May 1996
Resolved
RENEW DETERIORATED SEA WATER PIPING TO PORT ANCHOR WASH
Electrical
Issued 9 May 1996
Resolved
RENEW/REPAIR BROKEN LIGHT SWITCH TO EXPLOSION PROOF LIGHT LOCATED IN THE PAINT LOCKER
Electrical
Issued 9 May 1996
Resolved
RENEW/REPAIR INOPERABLE LIGHTS IN THE FWD EMERGENCY ESCAPE TRUNK FROM THE TUNNEL
Fire Fighting
Issued 9 May 1996
Resolved
RENEW/REPAIR DETERIORATED NATURAL VENT CLOSURE TO FWD DECK WORK SHOP.
Fire Fighting
Issued 9 May 1996
Resolved
INSTALL A RELIEF VALVE IN THE FIREMAIN TO PREVENT EMERGENCY FIRE PUMP FROM OVERPRESSURIZING THE FIREMAIN SYSTEM_x001C_ SOLAS 60 II/56(b)(iii)
Fire Fighting
Issued 9 May 1996
Resolved
RENEW MISSING SMOKE DETECTOR LOCATED AFT ENGINE ROOM UPPER LEVEL
Deck/Cargo
Issued 9 May 1996
Resolved
REMOVE EXCESS OIL/OIL RESIDUE LOCATED IN THE CONTAINMENTS ENGINE ROOM 3RD LEVEL STBD SIDE.
Fire Fighting
Issued 9 May 1996
Resolved
RENEW MISSING SMOKE DETECTOR LOCATED IN THE GENERATOR ROOM PORT SIDE
Fire Fighting
Issued 9 May 1996
Resolved
RENEW MISSING SMOKE DETECTOR LOCATED IN THE ENGINE ROOM 3RD LEVEL STBD SIDE
Deck/Cargo
Issued 9 May 1996
Resolved
REMOVE EXCESS OIL/OIL RESIDUE BENEATH THE DECK PLATES IN THE GENERATOR ROOM
Accommodation/Occupational Safety
Issued 9 May 1996
Resolved
REMOVE UN-APPROVED ALTERATIONS TO THE MAIN VENTILATION DUCTS LOCATED IN THEMAIN GENERATOR ROOM
Engineering
Issued 9 May 1996
Resolved
RENEW AS ORIGINAL DETERIORATED 2" WATER PIPE FROM DISTILLING PLANT LOCATED IN THE ENGINE ROOM 3RD LEVEL STBD SIDE OVERHEAD
Engineering
Issued 9 May 1996
Resolved
RENEW/REPAIR BROKEN (BENT) VALVE LOCATED IN THE ENGINER ROOM LOWER LEVEL BENEATH THE EJECTOR PUMP.
Deck/Cargo
Issued 9 May 1996
Resolved
REMOVE EXCESS OIL/OIL RESIDUE FROM ENGINE ROOM BILGES
Deck/Cargo
Issued 9 May 1996
Resolved
REMOVE EXCESS OIL/OIL RESIDUE FROM THE SEPERATOR ROOM
Fire Fighting
Issued 9 May 1996
Resolved
RENEW MISSING SMOKE DETECTOR LOCATED IN WAY OF THE ACCESS DOOR TO THE SEPERATOR ROOM
Construction/Loadline
Issued 9 May 1996
Resolved
RENEW AS ORIGINAL DETERIORATED PIPE LOCATED IN THE FWD SIDE OVERHEAD OF THESEPERATOR ROOM
Engineering
Issued 9 May 1996
Resolved
PROVE SATISFACTORY OPERATION OF THE OILY WATER SEPERATOR 15 PPM/ALARM SYSTEM TO THE SATISFACTION OF THE ATTENDING USCG INSPECTOR
Fire Fighting
Issued 9 May 1996
Resolved
RENEW AND PROVE SATISFACTORY OPERATION OF THE MISSING #2 MAIN FIRE PUMP
Deck/Cargo
Issued 9 May 1996
Resolved
REMOVE EXCESS OIL IN STEERING GEAR ROOM. REPAIR ALL HYDRAULIC LEAKS
Fire Fighting
Issued 9 May 1996
Resolved
CONDUCT A SATISFACTORY FIRE AND ABANDON SHIP DRILL TO THE SATISFACTION OF THE ATTENDING USCG INSPECTOR
Fire Fighting
Issued 9 May 1996
Resolved
RENEW ALL DEFECTIVE FIRE HOSES THROUGHOUT THE VESSEL. NOTED 40% OF THOSE CHECKED WERE HOLED. ALL FIRE HOSES THROUGHOUT THE VESSEL SHALL BE RENEWED AND/OR PRESSURE TESTED IN THE PRESENCE OF THE ATTENDING USCG INSPECTOR._x001C_ SOLAS 74 AMENDED II-2/21
Construction/Loadline
Issued 9 May 1996
Resolved
RENEW/REPAIR DETERIORATED ACCESS DOOR TO EMERGENCY GENERATOR ROOM.
Accommodation/Occupational Safety
Issued 9 May 1996
Resolved
RENEW/REPAIR INOPERABLE VENT. CLOSURE #5 LOCATED AFT OF THE EMERGENCY GENERATOR ROOM.
Electrical
Issued 9 May 1996
Resolved
RENEW/REPAIR BROKEN DECK LIGHT FIXTURE LOCATED STBD SIDE ON THE POOL DECK.
Accommodation/Occupational Safety
Issued 9 May 1996
Resolved
RENEW AS ORIGINAL DETERIORETED SEA WATER COOLING PIPE TO AIR COMPRESSURE LOCATED IN THE AIR CONDITIONING ROOM (AFT CENTER BOAT DECK)
Electrical
Issued 9 May 1996
Resolved
RENEW/REPAIR BROKEN DECK LIGHTING FIXTURE LOCATED STBD SIDE ON THE POOP DECK.
Documentation
Issued 18 December 1994
Resolved
COFR was not onboard.
Documentation
Issued 10 December 1994
Resolved
PROVIDE ON BOARD THE VESSEL ORIGINAL OFFICER LICENSES/CERTIFICATES OF COMPETENCY FOR ALL LICENSED CREW PRIOR TO DOCKAGE AT THE NEXT U.S. PORT.
Documentation
Issued 10 December 1994
Resolved
PROVIDE ON BOARD FROM THE GOVERNMENT OF THE BAHAMAS, ORIGINAL OFFICER LICENSES/CERTIFICATES OF COMPETENCY FOR ALL LICENSED CREW.
Documentation
Issued 10 December 1994
Resolved
PROVIDE ON BOARD/PROOF OF A VALID CERTIFICATE OF RESPONSIBILITY.
Navigation
Issued 8 June 1994
Resolved
REPAIR AND PROVE PROPER OPERATION OF FWD. STEERING MOTOR.
Navigation
Issued 22 September 1990
Resolved
Vessel entered the port of New York without reporting to the COTP that its secondary radar was inoperable. This is contrary to the requirements of_x001C_ 33 CFR 164.53.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.