Records from 1987 to 1990. Most recent: inspection, 18 January 1990.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 4
18 January 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 334832
18 January 1990
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 913893
19 January 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 313908
19 January 1987
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1318447
Navigation
Issued 18 January 1990
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITHOUT AN OPERATIONAL TRUE NORTH FUNCTION ON THE SECONDARY RADAR AS REQUIRED BY 33 CFR 164.37(B).
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 18 January 1990
Resolved
VESSEL DID NOT HAVE A TIDAL CURRENT TABLES ON BOARD AS REQUIRED BY 33 CFR 164.33(A)(3)(II).
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 18 January 1990
Resolved
VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES ON BOARD AS RE- QUIRED BY 33 CFR 88.05,
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 18 January 1990
Resolved
LIGHTING FIXTURES AT FWD STOW COMPT MUST BE MADE EXPLOSION PRROF PRIOR TO ENTRY INTO NEXT U.S. PORT.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Electrical
Issued 18 January 1990
Resolved
REPAIR OF REPLACE SWITCH TO SUEZ CANAL BEACON ON FOC SLE PRIOR TO ENTRY INTO NEXT U.S. PORT.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Engineering
Issued 18 January 1990
Resolved
REPAIR OR REPLACE CONTAINMENT AT PORT FUEL FILL MANIFOLD PRIOR TO RECEIVING BUNKERS ON PORT SIDE.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Navigation
Issued 18 January 1990
Resolved
REPAIR LEAK TO DISCH. PIPING CONNECTION (HYDRAULIC) ON PORT STEERING GEAR PUMP PRIOR TO DEPARTURE FROM PORT OF NEW YORK.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Navigation
Issued 18 January 1990
Resolved
INSTALL AUDIBLE ALARM ON BRIDGE FOR LOSS OF STEERING GEAR POWER (33 CFR 164.39)
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Electrical
Issued 19 January 1987
Resolved
REPLACE ALL LIGHT FIXTURE CABLE IN WAY OF THE PUMP ROOM.
Condition: Unknown
Due 19 January 1987
Resolved 19 January 1987
Fire Fighting
Issued 19 January 1987
Resolved
REPAIR SELF CONTAINED BREATHING APPARTUS LOCATED IN THE AFT FOAM ROOM AND PROVE ITS PROPER OPERATION.
Condition: Unknown
Due 19 January 1987
Resolved 19 January 1987
Navigation
Issued 19 January 1987
Resolved
NOS CHARTS 18720, 18749 AND USCG LIGHT LIST VOL. VI NOT CORRECTED TO DATE.
Condition: Unknown
Due 19 January 1987
Resolved 19 January 1987
Navigation
Issued 19 January 1987
Resolved
MANEUVERING INFORMATION POSTED ON THE BRIDGE NOT COMPLETE.
Condition: Unknown
Due 19 January 1987
Resolved 19 January 1987