MAURY USCG vessel records Sign in
← All vessels

SUERTE

SUERTE is a 1977 freight ship. The Coast Guard has recorded 13 inspections since 1985, most recently in March 1997, along with 28 deficiencies and 1 operational control.

Records from 1985 to 1997. Most recent: operational control imposed, 5 March 1997.

Built
1977
Last inspected
5 March 1997
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7409035 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225055
Flag
SOUTH KOREA
—
Maury page id
psix-225055

Inspections, by type

…with no type recorded13
Years with a record 10 calendar years (1985–1997)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it33408 - Regulatory (Subpart C or D), Gross Ton
55740 - Dead Weight, Ton
23476 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

5 March 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 401326
28 March 1996 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 389341
14 May 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 358194
17 March 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 113198
20 August 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 505046
6 February 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 335186
12 December 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 334164
22 July 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 324616
2 September 1987 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 318676
2 March 1987 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 314613
3 November 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 443945
30 January 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 306685
7 March 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 300698

Deficiency record · 28

Documentation
Issued 5 March 1997 Resolved
Provide evidence of proper manning with regards to the second and third mate prior to departure. _x001C_ _x001C_ SOLAS 74 amd V/13
Condition: Unknown
Due 15 March 1997
Resolved 13 March 1997
Fire Fighting
Issued 5 March 1997 Resolved
Repair the disabled fire doors to the aft upper level of the engineroom andboth entrances to the steering gear space. Remove any latches and maintaindoors in a closed position. Complete prior to return to a U. S. port. SOLAS 60 II/40
Condition: Unknown
Due 15 March 1997
Resolved 13 March 1997
Construction/Loadline
Issued 5 March 1997 Resolved
Provide a class report on the condition of the main deck between hatches 4 & 5, in regards to the areas with doubler plates, prior to return to a U. S. port._x001C_ ICLL 66 I/1
Condition: Unknown
Due 15 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 5 March 1997 Resolved
Make repairs to the focsle vent to the pipe tunnel and prove ability to maintain weather tight seal. Holes have also been noted in the fan enclosure. Complete prior to return to a U. S. port. _x001C_ ICLL 66 II/17
Condition: Unknown
Due 15 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 5 March 1997 Resolved
Make permanent repairs to the holed & leaking generator overboard check valve cover (stbd, LL) prior to return to a U. S. port. _x001C_ _x001C_ ICLL 66 II/22
Condition: Unknown
Due 15 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 5 March 1997 Resolved
Prove ability to start the emergency air compressor (in the engineroom) prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 15 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 5 March 1997 Resolved
Make permanent repairs to the air conditioning cooling line. The line has been renewed with a 4 inch hose fitted with band clamps. This is in the vicinity of the electric fire pumps. Complete prior to return to a U. S. port. SOLAS 60 I/11
Condition: Unknown
Due 15 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 5 March 1997 Resolved
Make permanent repairs to the patched M/E cooling lines in the overhead (inthe vicinity of the electric fire pumps) prior to return to a U. S. port. _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 15 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 5 March 1997 Resolved
Make permanent repairs to the patched outboard service pump inlet line (stbd, LL) prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 15 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 5 March 1997 Resolved
Make permanent repairs to the wasted & leaking line to the generator engine's fresh water heat exchanger prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 15 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 5 March 1997 Resolved
Make permanent repairs to the leaking cooling piping to the L/O heat exchanger on the fwd diesel generator engine prior to return to a U. S. port. _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 15 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 5 March 1997 Resolved
Make permanent repairs to the holed & leaking heat exchanger bell cover (fwd) on the aft generator engine prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 15 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 5 March 1997 Resolved
Make permanent repairs to the patched ejector line to the evaporator (port,fwd, LL) prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 15 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 5 March 1997 Resolved
Make permanent repairs to the patched evaporator line from the ballast manifold (centerline, forward) prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 15 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 5 March 1997 Resolved
Remove or replace the unapproved light fixture in the paint locker prior toreturn to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/27
Condition: Unknown
Due 15 March 1997
Resolved 13 March 1997
Deck/Cargo
Issued 5 March 1997 Resolved
Repair all leaking hatch hydraulic rams & controls. Clean oil from the decks to prevent entry into the water. Complete prior to return to a U. S.port. _x001C_ 33 CFR 151.10(b)
Condition: Unknown
Due 15 March 1997
Resolved 13 March 1997
Lifesaving
Issued 5 March 1997 Resolved
Provide belt drive covers for the reefer compressors, OWS pump and emergency air compressor prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 15 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 5 March 1997 Resolved
Repair the leaking oil filters / strainers on the aft generator engine prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 15 March 1997
Resolved 13 March 1997
Engineering
Issued 5 March 1997 Resolved
Clean the excessive oil from the E/R bilges, about all purifiers, the FOTP and the steering gear prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 15 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 5 March 1997 Resolved
Repair the F/O purifier where patched with Red Hand. Fix leaks in areas covered with rags. Repair the leaking air bleed cock on the FOTP strainer.Complete prior to return to a U. S. port. _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 15 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 5 March 1997 Resolved
Remove the broken drop light hanging between the generator engines. Removethe extension cords mounted on the wooden board by the fuel purifiers. Complete prior to return to a U. S. port. _x001C_ SOLAS 60 II/27
Condition: Unknown
Due 15 March 1997
Resolved 13 March 1997
Navigation
Issued 5 March 1997 Resolved
Replace the missing cotter pins on the steering gear linkages prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/29
Condition: Unknown
Due 15 March 1997
Resolved 13 March 1997
Lifesaving
Issued 5 March 1997 Resolved
Provide 2 lifejackets for the engineering watch prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 III/22
Condition: Unknown
Due 15 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 5 March 1997 Resolved
Remove the oxygen & acetylene HP bottles from the accommodation passage way, aft of the machinery spaces, prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 amd VII/6.1
Condition: Unknown
Due 15 March 1997
Resolved 13 March 1997
Documentation
Issued 12 December 1989 Resolved
VESSEL'S OIL RECORD BOOK DID NOT LIST THE DISPOSAL OF OIL RESIDUE RETAINED ONBOARD TO A RECEPTION FACILITY OR BURNED THROUGH THEIR INCINERATOR AS REQUIRED BY 33CFR151.25(D)(10).
Condition: Unknown
Due 7 March 1997
Resolved 7 March 1997
Navigation
Issued 7 March 1985 Resolved
VESSEL IS OVER 10,000 GROSS TONS AND HAS ONLY ONE OPERABLE RADAR.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Navigation
Issued 7 March 1985 Resolved
VESSEL DOES NOT HAVE MANEUVERING INFORMATION PROMINENTLY DISPLAYED. VESSEL HAS SOME INFORMATION, HOWEVER, IT IS SO OLD AND FADED THAT IT IS UNREADABLE.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Navigation
Issued 7 March 1985 Resolved
VESSEL HAS THE MOST RECENT AVAILABLE EDITIONS OF CHARTS, HOWEVER, THEY DO NOT HAVE ANY CORRECTIONS.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.